The DOI matches its Crossref record.
Water diffusion and exchange as they influence contrast enhancement
Abstract
The contrast‐enhanced magnetic resonance imaging (MRI) signal is rarely a direct measure of contrast concentration; rather it depends on the effect that the contrast agent has on the tissue water magnetization. To correctly interpret such studies, an understanding of the effects of water movement on the magnetic resonance (MR) signal is critical. In this review, we discuss how water diffusion within biological compartments and water exchange between these compartments affect MR signal enhancement and therefore our ability to extract physiologic information. The two primary ways by which contrast agents affect water magnetization are discussed: (1) direct relaxivity and (2) indirect susceptibility effects. For relaxivity agents, for which T1 effects usually dominate, the theory of relaxation enhancement is presented, along with a review of the relevant physiologic time constants for water movement affecting this relaxation enhancement. Experimental issues that impact accurate measurement of the relaxation enhancement are discussed. Finally, the impact of these effects on extracting physiologic information is presented. Susceptibility effects depend on the size and shape of the contrast agent, the size and shape of the compartment in which it resides, as well as the characteristics of the water movement through the resulting magnetic field inhomogeneity. Therefore, modeling of this effect is complex and is the subject of active study. However, since susceptibility effects can be much stronger than relaxivity effects in certain situations, they may be useful even without full quantitation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Self-citationQuantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Friedrich, M. G., Strohm, O., Schulz-Menger, J., Marciniak, H., Luft, F. C., & Dietz, R. (1998) · Circulation · doi:10.1161/01.cir.97.18.1802 · Cited by 558
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Saturation recovery single‐shot acquisition (SASHA) for myocardial T1 mapping
Chow, K., Flewitt, J. A., Green, J. D., Pagano, J. J., Friedrich, M. G., & Thompson, R. B. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24878 · Cited by 396
Metadata
- Authors
- Donahue, K. M., Weisskoff, R. M., & Burstein, D.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 1997-01
- Volume
- 7
- Issue
- 1
- Pages
- 102-110
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2171072107
- Cited by
- 270
- References
- 0
- FWCI
- 11.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Water diffusion and exchange as they influence contrast enhancement. https://app.cochat.ai/papers/10.1002/jmri.1880070114
- The paper
- Donahue, K. M., Weisskoff, R. M., & Burstein, D. (1997). Water diffusion and exchange as they influence contrast enhancement. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.1880070114
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.