Assessment of brain tumor angiogenesis inhibitors using perfusion magnetic resonance imaging: Quality and analysis results of a phase I trial
The DOI matches its Crossref record.
Abstract
Purpose: To determine thresholds of quality for a T2*‐weighted perfusion magnetic resonance imaging (MRI) study and evaluate the effects of an angiogenesis inhibitor on relative blood flow and volume changes in brain tumor patients in a multi‐institution setting. Materials and Methods: A total of 36 volunteers from four participating institutions with clinically diagnosed malignant gliomas were studied using perfusion MRI protocols. These included a baseline study and follow‐up studies every eight weeks to evaluate the effect of an anti‐angiogenic agent on tumor perfusion. Quality tests were performed on the perfusion imaging data by defining statistical thresholds of acceptance. Region of interest (ROI) analysis was performed on tumors and kinetic parameters were normalized with respect to normal tissue. Results: Statistical thresholds for goodness of the gamma variate fit, T2* recovery, and mean signal full‐width half‐minimum (FWHMin) were computed for our data sets with a 99% one‐sided confidence interval; these were 6.91%, 79.48%, and 23.35 seconds, respectively. Decreases inblood volume and flow measurements were observed in patients with documented clinical response. Conclusion: Malignant brain tumors have altered perfusion parameters that may be used to understand and monitor neovascularization. This permits non‐invasive assessment of the efficacy of angiogenesis inhibiting drugs. J. Magn. Reson. Imaging 2004;20:913–922. © 2004 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jain, R. K., di Tomaso, E., Duda, D. G., Loeffler, J. S., Sorensen, A. G., & Batchelor, T. T. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2175 · Cited by 1,405
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Disruption of astrocyte–vascular coupling and the blood–brain barrier by invading glioma cells
Watkins, S., Robel, S., Kimbrough, I. F., Robert, S. M., Ellis-Davies, G., & Sontheimer, H. (2014) · Nature Communications · doi:10.1038/ncomms5196 · Cited by 550
Reardon, D. A., Fink, K. L., Mikkelsen, T., Cloughesy, T. F., O'Neill, A., Plotkin, S., Glantz, M., Ravin, P., Raizer, J. J., Rich, K. M., et al. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2008.16.7510 · Cited by 481
Self-citationAmide proton transfer imaging of human brain tumors at 3T
Jones, C. K., Schlosser, M. J., van Zijl, P. C. M., Pomper, M. G., Golay, X., & Zhou, J. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20989 · Cited by 339
Metadata
- Authors
- Akella, N. S., Twieg, D. B., Mikkelsen, T., Hochberg, F. H., Grossman, S., Cloud, G. A., & Nabors, L. B.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2004-11-19
- Volume
- 20
- Issue
- 6
- Pages
- 913-922
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2132527182
- Cited by
- 83
- References
- 0
- FWCI
- 4.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of brain tumor angiogenesis inhibitors using perfusion magnetic resonance imaging: Quality and analysis results of a phase I trial. https://app.cochat.ai/papers/10.1002/jmri.20202
- The paper
- Akella, N. S., Twieg, D. B., Mikkelsen, T., Hochberg, F. H., Grossman, S., Cloud, G. A., & Nabors, L. B. (2004). Assessment of brain tumor angiogenesis inhibitors using perfusion magnetic resonance imaging: Quality and analysis results of a phase I trial. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.20202
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.