The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Amide proton transfer imaging of human brain tumors at 3T
Abstract
Amide proton transfer (APT) imaging is a technique in which the nuclear magnetization of water‐exchangeable amide protons of endogenous mobile proteins and peptides in tissue is saturated, resulting in a signal intensity decrease of the free water. In this work, the first human APT data were acquired from 10 patients with brain tumors on a 3T whole‐body clinical scanner and compared with T1‐ (T1 w) and T2‐weighted (T2 w), fluid‐attenuated inversion recovery (FLAIR), and diffusion images (fractional anisotropy (FA) and apparent diffusion coefficient (ADC)). The APT‐weighted images provided good contrast between tumor and edema. The effect of APT was enhanced by an approximate 4% change in the water signal intensity in tumor regions compared to edema and normal‐appearing white matter (NAWM). These preliminary data from patients with brain tumors show that the APT is a unique contrast that can provide complementary information to standard clinical MRI measures. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ward, K. M., Aletras, A. H., & Balaban, R. S. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.1999.1956 · Cited by 1,429
T1, T2 relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266
Using the amide proton signals of intracellular proteins and peptides to detect pH effects in MRI
Zhou, J., Payen, J.-F., Wilson, D. A., Traystman, R. J., & van Zijl, P. C. M. (2003) · Nature Medicine · doi:10.1038/nm907 · Cited by 1,198
Self-citationMagnetization transfer in MRI: a review
Henkelman, R. M., Stanisz, G. J., & Graham, S. J. (2001) · NMR in Biomedicine · doi:10.1002/nbm.683 · Cited by 921
Pajevic, S., & Pierpaoli, C. (2000) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200006)43:6<921::aid-mrm23>3.0.co;2-i · Cited by 763
Amide proton transfer (APT) contrast for imaging of brain tumors
Zhou, J., Lal, B., Wilson, D. A., Laterra, J., & van Zijl, P. C. M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10651 · Cited by 660
Self-citationPajevic, S., & Pierpaoli, C. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<526::aid-mrm15>3.0.co;2-j · Cited by 640
Griffiths, Jr. (1991) · British Journal of Cancer · doi:10.1038/bjc.1991.326 · Cited by 594
Howe, F. A., Barton, S. J., Cudlip, S. A., Stubbs, M., Saunders, D. E., Murphy, M., Wilkins, P., Opstad, K. S., Doyle, V. L., McLean, M. A., et al. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10367 · Cited by 539
PARACEST Agents: Modulating MRI Contrast via Water Proton Exchange
Zhang, S., Merritt, M., Woessner, D. E., Lenkinski, R. E., & Sherry, A. D. (2003) · Accounts of Chemical Research · doi:10.1021/ar020228m · Cited by 436
Cited by
Chemical exchange saturation transfer (CEST): what is in a name and what isn't?
van Zijl, P. C. M., & Yadav, N. N. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22761 · Cited by 1,155
Self-citationKim, M., Gillen, J., Landman, B. A., Zhou, J., & van Zijl, P. C. M. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21873 · Cited by 691
Self-citationMagnetic resonance imaging of glutamate
Cai, K., Haris, M., Singh, A., Kogan, F., Greenberg, J. H., Hariharan, H., Detre, J. A., & Reddy, R. (2012) · Nature Medicine · doi:10.1038/nm.2615 · Cited by 660
Artificial reporter gene providing MRI contrast based on proton exchange
Gilad, A. A., McMahon, M. T., Walczak, P., Winnard, P. T., Raman, V., van Laarhoven, H. W. M., Skoglund, C. M., Bulte, J. W. M., & van Zijl, P. C. M. (2007) · Nature Biotechnology · doi:10.1038/nbt1277 · Cited by 392
Self-citationChemical Exchange Saturation Transfer Contrast Agents for Magnetic Resonance Imaging
Sherry, A. D., & Woods, M. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151929 · Cited by 356
Metadata
- Authors
- Jones, C. K., Schlosser, M. J., van Zijl, P. C. M., Pomper, M. G., Golay, X., & Zhou, J.
- Venue
- Magnetic Resonance in Medicine
- Publisher
- Wiley
- Published
- 2006-08-04
- Volume
- 56
- Issue
- 3
- Pages
- 585-592
- ISSN
- 0740-3194 (ISSN-L)
- 1522-2594
- OpenAlex
- W2093861785
- Cited by
- 339
- References
- 36
- FWCI
- 5.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Amide proton transfer imaging of human brain tumors at 3T. https://app.cochat.ai/papers/10.1002/mrm.20989
- The paper
- Jones, C. K., Schlosser, M. J., van Zijl, P. C. M., Pomper, M. G., Golay, X., & Zhou, J. (2006). Amide proton transfer imaging of human brain tumors at 3T. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.20989
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.