The DOI matches its Crossref record.
Relaxation times of breast tissue at 1.5T and 3T measured using IDEAL
Open accessAbstract
Purpose: To accurately measure T1 and T2 of breast fibroglandular tissue and fat at 1.5T and 3T, and note the partial volume effects of the admixture of fibroglandular tissue and fat on the relaxation rates using an approach termed iterative decomposition of water and fat with echo asymmetry and least squares estimation (IDEAL) imaging. Materials and Methods: T1 and T2 values were measured on the right breasts of five healthy women at 1.5T and 3T. T1 data were collected using two sequences: inversion recovery without IDEAL, and inversion recovery with IDEAL. T2 data were collected using Hahn Echo scans. SNR and CNR analyses were conducted on collected data. Results: T1 increased for both fat (21%) and glandular tissue (17%) from 1.5T to 3T. Thus, the TR and TI of breast protocols at 3T should be lengthened accordingly. SNR more than doubled for both tissue types from 1.5T to 3T. IDEAL imaging demonstrated the partial volume effects of fat and glandular tissue on measuring relaxation rates of independent tissue types. Conclusion: With separated fat and water images, more precise measurements can be made for the lipid component in fat, and the water component in fibroglandular tissue. J. Magn. Reson. Imaging 2006. © 2005 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
What are normal relaxation times of tissues at 3 T?
Bojorquez, J. Z., Bricq, S., Acquitter, C., Brunotte, F., Walker, P. M., & Lalande, A. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.08.021 · Cited by 286
On the accuracy of T1 mapping: Searching for common ground
Stikov, N., Boudreau, M., Levesque, I. R., Tardif, C. L., Barral, J. K., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25135 · Cited by 285
Bernstein, M. A., Huston, J., & Ward, H. A. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20698 · Cited by 255
Metadata
- Authors
- Rakow‐Penner, R., Daniel, B., Yu, H., Sawyer‐Glover, A., & Glover, G. H.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2005-11-28
- Volume
- 23
- Issue
- 1
- Pages
- 87-91
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1983866899
- Cited by
- 196
- References
- 0
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relaxation times of breast tissue at 1.5T and 3T measured using IDEAL. https://app.cochat.ai/papers/10.1002/jmri.20469
- The paper
- Rakow‐Penner, R., Daniel, B., Yu, H., Sawyer‐Glover, A., & Glover, G. H. (2006). Relaxation times of breast tissue at 1.5T and 3T measured using IDEAL. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.20469
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.