What are normal relaxation times of tissues at 3 T?
Abstract
The T 1 and T 2 relaxation times are the basic parameters behind magnetic resonance imaging. The accurate knowledge of the T 1 and T 2 values of tissues allows to perform quantitative imaging and to develop and optimize magnetic resonance sequences. A vast extent of methods and sequences has been developed to calculate the T 1 and T 2 relaxation times of different tissues in diverse centers. Surprisingly, a wide range of values has been reported for similar tissues (e.g. T 1 of white matter from 699 to 1735ms and T 2 of fat from 41 to 371ms), and the true values that represent each specific tissue are still unclear, which have deterred their common use in clinical diagnostic imaging. This article presents a comprehensive review of the reported relaxation times in the literature in vivo at 3T for a large span of tissues. It gives a detailed analysis of the different methods and sequences used to calculate the relaxation times, and it explains the reasons of the spread of reported relaxation times values in the literature.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Cites
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · see citing works
Magnetic resonance fingerprinting
Ma, D., Gulani, V., Seiberlich, N., Liu, K., Sunshine, J. L., Duerk, J. L., & Griswold, M. A. (2013) · Nature · doi:10.1038/nature11971 · Cited by 1,577 · see citing works
T<sub>1</sub>, T<sub>2</sub> relaxation and magnetization transfer in tissue at 3T
Stanisz, G. J., Odrobina, E. E., Pun, J., Escaravage, M., Graham, S. J., Bronskill, M. J., & Henkelman, R. M. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20605 · Cited by 1,266 · see citing works
Adaptive non‐local means denoising of MR images with spatially varying noise levels
Manjón, J. V., Pierrick Coupé, A., Martí‐Bonmatí, L., Collins, D. L., & Robles, M. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22003 · Cited by 1,088 · see citing works
Yarnykh, V. L. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21120 · Cited by 1,028 · see citing works
de BAZELAIRE, C., Duhamel, G., Rofsky, N. M., & Alsop, D. C. (2004) · Radiology · doi:10.1148/radiol.2303021331 · Cited by 791 · see citing works
Proceedings of the International Society for Magnetic Resonance in Medicine
(2018) · Proceedings of the Society of Magnetic Resonance in Medicine · doi:10.1002/(issn)1557-3672 · Cited by 718 · see citing works
Piechnik, S. K., Ferreira, V. M., Dall’Armellina, E., Cochlin, L. E., Greiser, A., Neubauer, S., & Robson, M. D. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-69 · Cited by 670 · see citing works
Taylor, A. J., Salerno, M., Dharmakumar, R., et al. (2016) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2015.11.005 · Cited by 567 · see citing works
B 1 mapping by Bloch‐Siegert shift
Sacolick, L. I., Wiesinger, F., Hancu, I., & Vogel, M. W. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22357 · Cited by 529 · see citing works
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Gold, G. E., Han, E. T., Stainsby, J. A., et al. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.2.1830343 · Cited by 518 · see citing works
MR fingerprinting using fast imaging with steady state precession (FISP) with spiral readout
Jiang, Y., Ma, D., Seiberlich, N., Gulani, V., & Griswold, M. A. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25559 · Cited by 422 · see citing works
Cheng, H. M., & Wright, G. A. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20791 · Cited by 351 · see citing works
(2003) · Wiley eBooks · doi:10.1002/0470869526 · Cited by 347 · see citing works
Routine clinical brain MRI sequences for use at 3.0 Tesla
Lu, H., Nagae‐Poetscher, L. M., Golay, X., et al. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20356 · Cited by 329 · see citing works
On the accuracy of T<sub>1</sub> mapping: Searching for common ground
Stikov, N., Boudreau, M., Levesque, I. R., Tardif, C. L., Barral, J. K., & Pike, G. B. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25135 · Cited by 285 · see citing works
Myocardial T1 and T2 mapping at 3 T: reference values, influencing factors and implications
von Knobelsdorff‐Brenkenhoff, F., Prothmann, M., Dieringer, M. A., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-53 · Cited by 265 · see citing works
Wright, P., Mougin, O. E., Totman, J. J., Peters, A. M., Brookes, M. J., Coxon, R., Morris, P. E., Clemence, M., Francis, S., Bowtell, R. W., et al. (2008) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-008-0104-8 · Cited by 262 · see citing works
Artifacts in 3-T MRI: Physical background and reduction strategies
Dietrich, O., Reiser, M. F., & Schoenberg, S. O. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.11.005 · Cited by 250 · see citing works
Deoni, S. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21130 · Cited by 237 · see citing works
Preibisch, C., & Deichmann, R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21776 · Cited by 233 · see citing works
A robust methodology for in vivo T1 mapping
Barral, J. K., Gudmundson, E., Stikov, N., et al. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22497 · Cited by 217 · see citing works
How Does MRI Work? An Introduction to the Physics and Function of Magnetic Resonance Imaging
Weishaupt, D., Köchli, V. D., Marinček, B., et al. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.045104 · Cited by 212 · see citing works
Ethofer, T., Mader, I., Seeger, U., Helms, G., Erb, M., Grodd, W., Ludolph, A. C., & Klose, U. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10640 · Cited by 211 · see citing works
MR Fingerprinting for Rapid Quantitative Abdominal Imaging
Chen, Y., Jiang, Y., Pahwa, S. S., Ma, D., Lŭ, L., Twieg, M. D., Wright, K. L., Seiberlich, N., Griswold, M. A., & Gulani, V. (2016) · Radiology · doi:10.1148/radiol.2016152037 · Cited by 211 · see citing works
A Review on MR Image Intensity Inhomogeneity Correction
Hou, Z. (2006) · International Journal of Biomedical Imaging · doi:10.1155/ijbi/2006/49515 · Cited by 201 · see citing works
Relaxation times of breast tissue at 1.5T and 3T measured using IDEAL
Rakow‐Penner, R., Daniel, B. L., Yu, H., et al. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20469 · Cited by 194 · see citing works
Fast and precise T1 imaging using a TOMROP sequence
Brix, G., Schad, L. R., Deimling, M., & Lorenz, W. J. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90041-y · Cited by 176 · see citing works
A comparative study at 3 T of sequence dependence of T2 quantitation in the knee
Pai, A., Li, X., & Majumdar, S. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.02.017 · Cited by 104 · see citing works
Free-Breathing 3 T Magnetic Resonance T2-Mapping of the Heart
van Heeswijk, R. B., Feliciano, H., Bongard, C., Bonanno, G., Coppo, S., Lauriers, N., Locca, D., Schwitter, J., & Stuber, M. (2012) · JACC. Cardiovascular imaging · doi:10.1016/j.jcmg.2012.06.010 · Cited by 95 · see citing works
T 1 Mapping using variable flip angle SPGR data with flip angle correction
Liberman, G., Louzoun, Y., & Bashat, D. B. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24373 · Cited by 87 · see citing works
Towards quantitative measurements of relaxation times and other parameters in the brain
Tofts, P. S., & Boulay, E. (1990) · Neuroradiology · doi:10.1007/bf00588474 · Cited by 74 · see citing works
Shin, W., Gu, H., & Yang, Y. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21836 · Cited by 72 · see citing works
Fennessy, F. M., Fedorov, A., Gupta, S., Schmidt, E. J., Tempany, C. M., & Mulkern, R. V. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.011 · Cited by 70 · see citing works
Transmit field inhomogeneity and T 1 estimation errors in breast DCE‐MRI at 3 tesla
Sung, K., Daniel, B. L., & Hargreaves, B. A. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23996 · Cited by 65 · see citing works
Deoni, S., Rutt, B. K., Parrent, A. G., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.09.016 · Cited by 65 · see citing works
T1 mapping using spoiled FLASH‐EPI hybrid sequences and varying flip angles
Preibisch, C., & Deichmann, R. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21969 · Cited by 64 · see citing works
An analysis of the accuracy of magnetic resonance flip angle measurement methods
Morrell, G., & Schabel, M. C. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/20/008 · Cited by 63 · see citing works
Dieringer, M. A., Deimling, M., Santoro, D., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0091318 · Cited by 55 · see citing works
Segmentation of the thalamus in MRI based on T1 and T2
Traynor, C., Barker, G. J., Crum, W. R., Williams, S., & Richardson, M. P. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.083 · Cited by 53 · see citing works
T 1 : The Longitudinal Relaxation Time
Gowland, P. A., & Stevenson, V. L. (2003) · doi:10.1002/0470869526.ch5 · Cited by 40 · see citing works
Brief, E., Whittall, K. P., Li, D. K. B., et al. (2003) · NMR in Biomedicine · doi:10.1002/nbm.857 · Cited by 39 · see citing works
Multicentre imaging measurements for oncology and in the brain
Tofts, P. S., & Collins, D. J. (2011) · British Journal of Radiology · doi:10.1259/bjr/74316620 · Cited by 39 · see citing works
Metabolite ratios in 1H MR spectroscopic imaging of the prostate
Kobus, T., Wright, A. J., Weiland, E., et al. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25122 · Cited by 38 · see citing works
Longitudinal and multi‐echo transverse relaxation times of normal breast tissue at 3 Tesla
Edden, R. A. E., Smith, S. A., & Barker, P. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22306 · Cited by 37 · see citing works
T 2 : The Transverse Relaxation Time
Boulby, P. A., & Rugg‐Gunn, F. J. (2003) · doi:10.1002/0470869526.ch6 · Cited by 34 · see citing works
3D myocardial T1 mapping at 3T using variable flip angle method: Pilot study
Poinsignon-Clique, H., Cheng, H. M., Marie, P., et al. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24688 · Cited by 33 · see citing works
Observations of quantum dynamics by solution-state NMR spectroscopy
Pravia, M. A., Fortunato, E. M., Weinstein, Y. S., Price, M. D., Teklemariam, G., Nelson, R. J., Sharf, Y., Somaroo, S. S., Tseng, C.-H., Havel, T. F., et al. (1999) · Concepts in Magnetic Resonance · doi:10.1002/(sici)1099-0534(1999)11:4 · Cited by 29 · see citing works
A novel method for simultaneous 3D B1 and T1 mapping: the method of slopes (MoS)
Chavez, S., & Stanisz, G. J. (2012) · NMR in Biomedicine · doi:10.1002/nbm.2769 · Cited by 26 · see citing works
MRI from A to Z: A Definitive Guide for Medical Professionals
Liney, G. P. (2010) · Digital Access to Libraries (Université catholique de Louvain (UCL), l'Université de Namur (UNamur) and the Université Saint-Louis (USL-B)) · doi:10.1007/978-1-84996-135-6 · Cited by 24 · see citing works
Samson, R. S., Ciccarelli, O., Kachramanoglou, C., Brightman, L., Lutti, A., Thomas, D. L., Weiskopf, N., & Wheeler‐Kingshott, C. A. M. G. (2013) · NMR in Biomedicine · doi:10.1002/nbm.3022 · Cited by 23 · see citing works
TriTone: a radiofrequency field (B1)-insensitive T1 estimator for MRI at high magnetic fields
Fleysher, R., Fleysher, L., Liu, S., & Gonen, O. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2008.01.024 · Cited by 23 · see citing works
A novel alternative to classify tissues from T 1 and T 2 relaxation times for prostate MRI
Bojorquez, J. Z., Bricq, S., Brunotte, F., et al. (2016) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-016-0562-3 · Cited by 22 · see citing works
Self-citationMeasuring T2 and T1, and imaging T2 without spin echoes
Wang, G., El‐Sharkawy, A. M., Edelstein, W. A., et al. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.11.016 · Cited by 21 · see citing works
Comparison of three multichannel TX/RX coils for anatomic and functional CMR at 7.0T
Winter, L., Kellman, P., Renz, W., et al. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-s1-w24 · Cited by 19 · see citing works
de Roquefeuil, M., Vuissoz, P., Escanyé, J., et al. (2013) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2013.06.006 · Cited by 15 · see citing works
Piechnik, S. K., Ferreira, V. M., Dall’Armellina, E., et al. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-s1-o70 · Cited by 13 · see citing works
Template-Based $B _{1}$ Inhomogeneity Correction in 3T MRI Brain Studies
Castro, M. A., Yao, J., Pang, Y., et al. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053552 · Cited by 10 · see citing works
T1 mapping: Methods and challenges
Stikov, N., Tardif, C. L., Barral, J. K., et al. (2011) · PolyPublie (École Polytechnique de Montréal) · Cited by 2 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
An overview of deep learning in medical imaging focusing on MRI
Lundervold, A. S., & Lundervold, A. (2019) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2018.11.002 · Cited by 2,058 · see citing works
- Authors
- Bojorquez, J. Z., Bricq, S., Acquitter, C., Brunotte, F., Walker, P. M., & Lalande, A.
- Affiliations
- Centre National de la Recherche Scientifique (FR)
- Corresponding author
- Lalande, Alain
- Venue
- Magnetic Resonance Imaging
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 35
- Pages
- 69-80
- ISSN
- 0730-725X (ISSN-L)
- OpenAlex
- W2507707535
- Cited by
- 286
- References
- 59
- Citations by year
- 2026: 25 · 2025: 36 · 2024: 48 · 2023: 35 · 2022: 35 · 2021: 36 · 2020: 27 · 2019: 21 · 2018: 15 · 2017: 7
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Magnetic Resonance Imaging (publishedVersion)
- PubMed (publishedVersion)
- HAL (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
- Physical Sciences › Physics and Astronomy › Nuclear and High Energy Physics › NMR spectroscopy and applications
- Keywords
- T1 relaxation time, T2 relaxation time, tissue relaxation times, 3T MRI, quantitative MRI, white matter, fats, inter-laboratory variability
- MeSH terms
- Humans, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Time
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review