Diffusion tensor imaging in evaluation of human skeletal muscle injury
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Purpose: To explore the capability and reliability of diffusion tensor magnetic resonance imaging (DTI) in the evaluation of human skeletal muscle injury. Materials and Methods: DTI of four patients with gastrocnemius and soleus muscles injuries was compared to eight healthy controls. Imaging was performed using a GE 3.0T short‐bore scanner. A diffusion‐weighted 2D spin echo echo‐planar imaging (EPI) pulse sequence optimized for skeletal muscle was used. From a series of axially acquired diffusion tensor images the diffusion tensor eigenparameters (eigenvalues and eigenvectors), fractional anisotropy (FA), and apparent diffusion coefficient (ADC) were calculated and compared for injured and healthy calf muscles. Two dimensional (2D) projection maps of the principal eigenvectors were plotted to visualize the healthy and pathologic muscle fiber architectures. Results: Clear differences in FA and ADC were observed in injured skeletal muscle, compared to healthy controls. Mean control FA was 0.23 ± 0.02 for medial and lateral gastrocnemius (mg and lg) muscles, and 0.20 ± 0.02 for soleus (sol) muscles. In all patients FA values were reduced compared to controls, to as low as 0.08 ± 0.02. The ADC in controls ranged from 1.41 to 1.31 × 10–9 m 2/second, while in patients this was consistently higher. The 2D projection maps revealed muscle fiber disorder in injured calves, while in healthy controls the 2D projection maps show a well organized (ordered) fiber structure. Conclusion: DTI is a suitable method to assess human calf muscle injury. J. Magn. Reson. Imaging 2006. © 2006 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Water diffusion changes in wallerian degeneration and their dependence on white matter architecture
Pierpaoli, C., Barnett, A., Pajevic, S., Chen, R., Penix, L., Virta, A., & Basser, P. (2001) · NeuroImage · doi:10.1006/nimg.2001.0765 · Cited by 938
Diffusion tensor imaging of neurodevelopment in children and young adults.
Snook, L., Paulson, L.-A., Roy, D., Phillips, L., & Beaulieu, C. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.016 · Cited by 350 · cited 2×
“The measured ADC value is often used to assess tissue lesions (2,6,8,26,27).”
BackgroundMethodDiffusion tensor imaging in biomechanical studies of skeletal muscle function
VAN DONKELAAR, C. C., KRETZERS, L. J. G., BOVENDEERD, P. H. M., LATASTER, L. M. A., NICOLAY, K., JANSSEN, J. D., & DROST, M. R. (1999) · Journal of Anatomy · doi:10.1046/j.1469-7580.1999.19410079.x · Cited by 141
Cited by
Carlier, P. G., Marty, B., Scheidegger, O., Loureiro de Sousa, P., Baudin, P.-Y., Snezhko, E., & Vlodavets, D. (2016) · Journal of Neuromuscular Diseases · doi:10.3233/jnd-160145 · Cited by 186
“Magnetization transfer contrast is high in the skeletal muscle and its origin and mechanisms have been studied by several groups in normal, aging and diseased muscles, with a particular attention but yet poorly understood link to fibrosis [151, 152, 182, 214, 224, 225].”
BackgroundMuscle analysis using pQCT, DXA and MRI
Erlandson, M. C., Lorbergs, A. L., Mathur, S., & Cheung, A. M. (2016) · European Journal of Radiology · doi:10.1016/j.ejrad.2016.03.001 · Cited by 166
Metadata
- Authors
- Zaraiskaya, T., Kumbhare, D., & Noseworthy, M. D.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2006-07-05
- Volume
- 24
- Issue
- 2
- Pages
- 402-408
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2032234501
- Cited by
- 213
- References
- 5
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.