Jasperse, Bas, Valsasina, Paola, Neacsu, Veronica, Knol, Dirk L., De Stefano, Nicola, Enzinger, Christian, Smith, Stephen M., Ropele, Stefan, Korteweg, Tijmen, Giorgio, Antonio, Anderson, Valerie, Polman, Chris H., Filippi, Massimo, Miller, David H., Rovaris, Marco, Barkhof, Frederik, Vrenken, Hugo · 2007 · Journal of Magnetic Resonance Imaging
Cited by 49

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Purpose: To investigate intercenter agreement of brain volume (change) measurement in multiple sclerosis (MS) using structural image evaluation using normalization of atrophy (SIENA) and the cross‐sectional version of SIENA (SIENAX) with additional manual editing to correct for inadequate brain extraction. Materials and Methods: Baseline and follow‐up T1‐weighted MR images of 20 MS patients were dispatched to five centers. Each center performed fully‐automated and manually‐edited analyses for SIENAX, yielding normalized brain volume (NBV), and SIENA, yielding percentage brain volume change (PBVC). Intercenter agreement was assessed with the concordance correlation coefficient (CCC). Results: Intercenter agreement was perfect for fully automated NBV and PBVC (both CCC = 1.0), and remained substantial upon manual editing (CCC = 0.94 for NBV, CCC = 0.95 for PBVC). Mean NBV values for each center decreased significantly after manual editing (overall mean NBV = 1605.3 cm3 vs. 1651.1 cm3 without manual editing; t = –4.58, P < 0.001). Total variance in PBVC decreased significantly by a factor of 1.8 after manual editing (σ 2 = 2.82 before, and σ 2 = 1.54 after manual editing, P < 0.05). Conclusion: Substantial intercenter agreement was found for manually‐edited SIENAX and SIENA, suggesting that measurements from multiple centers may be pooled. Manual editing reduces overestimation of NBV, and is likely to increase statistical power for PBVC. J. Magn. Reson. Imaging 2007;26:881–885. © 2007 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.21101

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Jasperse, B., Valsasina, P., Neacsu, V., Knol, D. L., De Stefano, N., Enzinger, C., Smith, S. M., Ropele, S., Korteweg, T., Giorgio, A., Anderson, V., Polman, C. H., Filippi, M., Miller, D. H., Rovaris, M., Barkhof, F., & Vrenken, H.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2007-09-25
Volume
26
Issue
4
Pages
881-885
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2062885725
Cited by
49
References
1
FWCI
3.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.