The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Biochemical safety profiles of gadolinium‐based extracellular contrast agents and nephrogenic systemic fibrosis
Open accessAbstract
Gadolinium (Gd)‐based paramagnetic contrast agents are relatively safe when used in clinically recommended doses. However, with the rapidly expanding body of literature linking Gd‐based paramagnetic contrast agents and nephrogenic systemic fibrosis (NSF), awareness of the potential side effects and adverse reactions from Gd is now an important requirement for practicing radiologists. In addition to the ongoing accumulation and analyses of clinical NSF data, it is also essential for the practicing radiologist to understand the biochemical characteristics of the extracellular Gd‐chelates. The purpose of this review is to consolidate and update the available information on known side effects, adverse reactions, and toxicity of the Gd chelates, with particular emphasis on the potential mechanisms of NSF. J. Magn. Reson. Imaging 2007;26:1190–1197. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grobner, T. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfk062 · Cited by 1,859
Marckmann, P., Skov, L., Rossen, K., Dupont, A., Damholt, M. B., Heaf, J. G., & Thomsen, H. S. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006060601 · Cited by 1,400
Nephrogenic Systemic Fibrosis: Risk Factors and Incidence Estimation
Sadowski, E. A., Bennett, L. K., Chan, M. R., Wentland, A. L., Garrett, A. L., Garrett, R. W., & Djamali, A. (2007) · Radiology · doi:10.1148/radiol.2431062144 · Cited by 1,018
Biochemistry of the Lanthanides
Evans, C. H. (1990) · Springer eBooks · doi:10.1007/978-1-4684-8748-0 · Cited by 639
Gadolinium-based MR Contrast Agents and Nephrogenic Systemic Fibrosis
Kuo, P. H., Kanal, E., Abu-Alfa, A. K., & Cowper, S. E. (2007) · Radiology · doi:10.1148/radiol.2423061640 · Cited by 630
Gadodiamide-Associated Nephrogenic Systemic Fibrosis: Why Radiologists Should Be Concerned
Broome, D. R., Girguis, M. S., Baron, P. W., Cottrell, A. C., Kjellin, I., & Kirk, G. A. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1094 · Cited by 604
The use of iodinated and gadolinium contrast media during pregnancy and lactation
Webb, J. A. W., Thomsen, H. S., Morcos, S. K., & Members of Contrast Media Safety Committee of European Society of Urogenital Radiology (ESUR) (2005) · European Radiology · doi:10.1007/s00330-004-2583-y · Cited by 590
Gadolinium is detectable within the tissue of patients with nephrogenic systemic fibrosis
High, W. A., Ayers, R. A., Chandler, J., Zito, G., & Cowper, S. E. (2007) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2006.10.047 · Cited by 545
Laurent, S., Elst, L. V., & Muller, R. N. (2006) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.100 · Cited by 441
The relationship between thermodynamics and the toxicity of gadolinium complexes
Cacheris, W. P., Quay, S. C., & Rocklage, S. M. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90055-7 · Cited by 436
Cited by
Magnetic nanoparticles: preparation, physical properties, and applications in biomedicine
Akbarzadeh, A., Samiei, M., & Davaran, S. (2012) · Nanoscale Research Letters · doi:10.1186/1556-276x-7-144 · Cited by 1,241
Nanoscale Metal–Organic Frameworks for Therapeutic, Imaging, and Sensing Applications
Lu, K., Aung, T., Guo, N., Weichselbaum, R., & Lin, W. (2018) · Advanced Materials · doi:10.1002/adma.201707634 · Cited by 692
Villaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Harnessing albumin as a carrier for cancer therapies
Hoogenboezem, E. N., & Duvall, C. L. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.07.011 · Cited by 610
Gadodiamide-Associated Nephrogenic Systemic Fibrosis: Why Radiologists Should Be Concerned
Broome, D. R., Girguis, M. S., Baron, P. W., Cottrell, A. C., Kjellin, I., & Kirk, G. A. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1094 · Cited by 604
Classification and basic properties of contrast agents for magnetic resonance imaging
Geraldes, C. F. G. C., & Laurent, S. (2009) · Contrast Media & Molecular Imaging · doi:10.1002/cmmi.265 · Cited by 541
Gadolinium(iii) complexes as MRI contrast agents: ligand design and properties of the complexes
Hermann, P., Kotek, J., Kubíček, V., & Lukeš, I. (2008) · Dalton Transactions · doi:10.1039/b719704g · Cited by 530
Gadolinium-Based Contrast Agent Accumulation and Toxicity: An Update
Ramalho, J., Semelka, R. C., Ramalho, M., Nunes, R. H., AlObaidy, M., & Castillo, M. (2016) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4615 · Cited by 453
MRI contrast agents: Basic chemistry and safety
Hao, D., Ai, T., Goerner, F., Hu, X., Runge, V. M., & Tweedle, M. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23725 · Cited by 336
Iron Oxide Nanoparticle Based Contrast Agents for Magnetic Resonance Imaging
Shen, Z., Wu, A., & Chen, X. (2017) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.6b00839 · Cited by 328
Spinel ferrite nanoparticles and nanocomposites for biomedical applications and their toxicity
Kefeni, K. K., Msagati, T. A. M., Nkambule, T. T., & Mamba, B. B. (2020) · Materials Science and Engineering: C · doi:10.1016/j.msec.2019.110314 · Cited by 314
Magnetic Nanoparticles as MRI Contrast Agents
Avasthi, A., Caro, C., Pozo-Torres, E., Leal, M. P., & García-Martín, M. L. (2020) · Topics in Current Chemistry · doi:10.1007/s41061-020-00302-w · Cited by 253
Han, B. K., Rigsby, C. K., Hlavacek, A., Leipsic, J., Nicol, E. D., Siegel, M. J., Bardo, D., Abbara, S., Ghoshhajra, B., Lesser, J. R., et al. (2015) · Journal of Cardiovascular Computed Tomography · doi:10.1016/j.jcct.2015.07.004 · Cited by 211
Small animal cardiovascular MR imaging and spectroscopy
Bakermans, A. J., Abdurrachim, D., Moonen, R. P. M., Motaal, A. G., Prompers, J. J., Strijkers, G. J., Vandoorne, K., & Nicolay, K. (2015) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2015.03.001 · Cited by 35
Applications and Efficacy of Iron Oxide Nanoparticles in the Treatment of Brain Tumors
Varalli, L., Berlet, R., Abenojar, E., McDaid, J., Gascoigne, D. A., Bailes, J., & Aksenov, D. P. (2025) · Pharmaceutics · doi:10.3390/pharmaceutics17040499 · Cited by 23
Metadata
- Authors
- Ersoy, H., & Rybicki, F. J.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2007-10-29
- Volume
- 26
- Issue
- 5
- Pages
- 1190-1197
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1963655497
- Cited by
- 283
- References
- 45
- FWCI
- 11.52
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.