Investigation and validation of intersite fMRI studies using the same imaging hardware
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Purpose: To provide a between‐site comparison of functional MRI (fMRI) signal reproducibility in two laboratories equipped with identical imaging hardware and software. Many studies have looked at within‐subject reliability and more recent efforts have begun to calibrate responses across sites, magnetic field strengths, and software. By comparing identical imaging hardware and software, we provide a benchmark for future multisite comparisons. Materials and Methods: We evaluated system compatibility based on noise and stability properties of phantom scans and contrast estimates from repeated runs of a blocked motor and visual task on the same four subjects at both sites. Results: Analysis of variance (ANOVA) and region of interest (ROI) analysis confirmed that site did not play a significant role in explaining variance in our large fMRI dataset. Effect size analysis shows that between‐subject differences account for nearly 10 times more variance than site effects. Conclusion: We show that quantitative comparisons of contrast estimates derived from cognitive experiments can reliably be compared across two sites. This allows us to establish an effective platform for comparing group differences between two sites using fMRI when group effects are potentially confounded with site, as in the study of neurocultural differences between countries or multicenter clinical trials. J. Magn. Reson. Imaging 2008;28:21–28. © 2008 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628
Olejnik, S., & Algina, J. (2003) · Psychological Methods · doi:10.1037/1082-989x.8.4.434 · Cited by 1,622 · cited 3×
“We used the generalized G 2 from Olejnik and Algina (26) to provide a measure of effect size that should be robust to the specific effects (including task) that were included in the ANOVA analysis.”
InfluentialAge and culture modulate object processing and object—scene binding in the ventral visual area
Goh, J. O., Chee, M. W., Tan, J. C., Venkatraman, V., Hebrank, A., Leshikar, E. D., Jenkins, L., Sutton, B. P., Gutchess, A. H., & Park, D. C. (2007) · Cognitive, Affective, & Behavioral Neuroscience · doi:10.3758/cabn.7.1.44 · Cited by 202
Self-citation
Cited by
Zhou, J., Greicius, M. D., Gennatas, E. D., Growdon, M. E., Jang, J. Y., Rabinovici, G. D., Kramer, J. H., Weiner, M., Miller, B. L., & Seeley, W. W. (2010) · Brain · doi:10.1093/brain/awq075 · Cited by 1,016
A Cultural Neuroscience Approach to the Biosocial Nature of the Human Brain
Han, S., Northoff, G., Vogeley, K., Wexler, B. E., Kitayama, S., & Varnum, M. E. W. (2013) · Annual Review of Psychology · doi:10.1146/annurev-psych-071112-054629 · Cited by 427
What is a representative brain? Neuroscience meets population science
Falk, E. B., Hyde, L. W., Mitchell, C., Faul, J., Gonzalez, R., Heitzeg, M. M., Keating, D. P., Langa, K. M., Martz, M. E., Maslowsky, J., et al. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1310134110 · Cited by 265
Age and culture modulate object processing and object—scene binding in the ventral visual area
Goh, J. O., Chee, M. W., Tan, J. C., Venkatraman, V., Hebrank, A., Leshikar, E. D., Jenkins, L., Sutton, B. P., Gutchess, A. H., & Park, D. C. (2007) · Cognitive, Affective, & Behavioral Neuroscience · doi:10.3758/cabn.7.1.44 · Cited by 202
Self-citationA methodological checklist for fMRI drug cue reactivity studies: development and expert consensus
Ekhtiari, H., Zare-Bidoky, M., Sangchooli, A., Janes, A. C., Kaufman, M. J., Oliver, J. A., Prisciandaro, J. J., Wüstenberg, T., Anton, R. F., Bach, P., et al. (2022) · Nature Protocols · doi:10.1038/s41596-021-00649-4 · Cited by 89
Metadata
- Authors
- Sutton, B. P., Goh, J., Hebrank, A., Welsh, R. C., Chee, M. W. L., & Park, D. C.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2008-06-25
- Volume
- 28
- Issue
- 1
- Pages
- 21-28
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2147779598
- Cited by
- 54
- References
- 3
- FWCI
- 2.63
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Investigation and validation of intersite fMRI studies using the same imaging hardware. https://app.cochat.ai/papers/10.1002/jmri.21419
- The paper
- Sutton, B. P., Goh, J., Hebrank, A., Welsh, R. C., Chee, M. W. L., & Park, D. C. (2008). Investigation and validation of intersite fMRI studies using the same imaging hardware. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21419
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.