Removing background phase variations in susceptibility‐weighted imaging using a fast, forward‐field calculation
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Purpose: To estimate magnetic field variations induced from air–tissue interface geometry and remove their effects from susceptibility‐weighted imaging (SWI) data. Materials and Methods: A Fourier transform–based field estimation method is used to calculate the field deviation arising from air–tissue interface geometry. This is accomplished by manually drawing or automatically detecting the sinuses, the mastoid cavity, and the head geometry. The difference in susceptibility, Δχ, between brain tissue and air spaces is then calculated using a residual‐phase minimization approach. SWI data are corrected by subtracting the predicted phase from the original phase images. Resultant phase images are then used to perform the SWI postprocessing. Results: Significant improvement in the postprocessed SWI data is demonstrated, most notably in the frontal and midbrain regions and to a lesser extent at the boundary of the brain. Specifically, there is much less dropout of signal after phase correction near air–tissue interfaces, making it possible to see vessels and structures that were often incorrectly removed by the conventional SWI postprocessing. Conclusion: The Fourier transform–based field estimation method is a powerful 3D background phase removal method for improving SWI images, providing clearer images of the forebrain and the midbrain regions. J. Magn. Reson. Imaging 2009;29:937–948. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Susceptibility weighted imaging (SWI)
Haacke, E. M., Xu, Y., Cheng, Y. N., & Reichenbach, J. R. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20198 · Cited by 1,582
Self-citationImaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Self-citation
Cited by
de Rochefort, L., Liu, T., Kressler, B., Liu, J., Spincemaille, P., Lebon, V., Wu, J., & Wang, Y. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22187 · Cited by 670
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
Self-citationMRI estimates of brain iron concentration in normal aging using quantitative susceptibility mapping
Bilgic, B., Pfefferbaum, A., Rohlfing, T., Sullivan, E. V., & Adalsteinsson, E. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.077 · Cited by 499
A novel background field removal method for MRI using projection onto dipole fields (PDF)
Liu, T., Khalidov, I., de Rochefort, L., Spincemaille, P., Liu, J., Tsiouris, A. J., & Wang, Y. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1670 · Cited by 455
Overview of quantitative susceptibility mapping
Deistung, A., Schweser, F., & Reichenbach, J. R. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3569 · Cited by 338
Susceptibility mapping as a means to visualize veins and quantify oxygen saturation
Haacke, E. M., Tang, J., Neelavalli, J., & Cheng, Y. C. N. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22276 · Cited by 306
Self-citationSusceptibility mapping in the human brain using threshold‐based k‐space division
Wharton, S., Schäfer, A., & Bowtell, R. (2010) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22334 · Cited by 244
“, this information was collected through acquisition of additional high-resolution T1-weighted images (22).”
BackgroundMethodZivadinov, R., Brown, M. H., Schirda, C. V., Poloni, G. U., Bergsland, N., Magnano, C. R., Durfee, J., Kennedy, C., Carl, E., Hagemeier, J., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.045 · Cited by 188
“, 2009), which takes advantage of the harmonic nature of background fields, and by reducing external phase errors and hence reducing the size of the high pass filter (Neelavalli et al., 2009).”
Measuring iron in the brain using quantitative susceptibility mapping and X-ray fluorescence imaging
Zheng, W., Nichol, H., Liu, S., Cheng, Y.-C. N., & Haacke, E. M. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.022 · Cited by 175
“The susceptibility inside each of the ferritin straws was assumed to be uniform andwas estimated using a least squares fitting of the forward simulated dipole phase with the estimated phase (Neelavalli et al., 2009).”
Self-citation
Metadata
- Authors
- Neelavalli, J., Cheng, Y. N., Jiang, J., & Haacke, E. M.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2009-03-20
- Volume
- 29
- Issue
- 4
- Pages
- 937-948
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2099911985
- Cited by
- 76
- References
- 2
- FWCI
- 6.11
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.