Accurate segmentation of subcutaneous and intermuscular adipose tissue from MR images of the thigh
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Purpose: To describe and evaluate a computer‐assisted method for assessing the quantity and distribution of adipose tissue in thigh by magnetic resonance imaging (MRI). Materials and Methods: Twenty obese subjects were imaged on a Philips Achieva 1.5T scanner by a fast spin‐echo (FSE) sequence. A total of 636 images were acquired and analyzed by custom‐made software. Thigh subcutaneous adipose tissue (SAT) and bone were identified by fuzzy clustering segmentation and an active contour algorithm. Muscle and intermuscular adipose tissue (IMAT) were assessed by identifying the two peaks of the signal histogram with an expectation maximization algorithm. The whole analysis was performed in an unsupervised manner without the need of any user interaction. Results: The coefficient of variation (CV) was evaluated between the unsupervised algorithm and manual analysis performed by an expert operator. The CV was low for all measurements (SAT <2%, muscle <1%, IMAT <5%). Limited manual correction of unsupervised segmentation results (less than 10% of contours modified) allowed us to further reduce the CV (SAT <0.5%, muscle <0.5%, IMAT <2%). Conclusion: The proposed approach allowed effective computer‐assisted analysis of thigh MR images, dramatically reducing the user work compared to manual analysis. It allowed routine assessment of IMAT, a fat‐depot linked with metabolic abnormalities, important in monitoring the effect of nutrition and exercise. J. Magn. Reson. Imaging 2009;29:677–684. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731 · cited 1×
“The well-established N3 algorithm (24) was successfully used for thigh images preprocessing by Manini et al (6).”
MethodSnakes, shapes, and gradient vector flow
Xu, C., & Prince, J. L. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.661186 · Cited by 4,001 · cited 2×
“The GVF field increases the range of convergence of the active contours algorithm (16).”
BackgroundMethodGoodpaster, B. H., Thaete, F. L., & Kelley, D. E. (2000) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/71.4.885 · Cited by 707 · cited 2×
“[4,] adding a constant signal value to the second Gaussian peak, the partial volume effect can be modeled, thus improving IMAT detection performance.”
BackgroundAdipose tissue in muscle: a novel depot similar in size to visceral adipose tissue
Gallagher, D., Kuznia, P., Heshka, S., Albu, J., Heymsfield, S. B., Goodpaster, B., Visser, M., & Harris, T. B. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/81.4.903 · Cited by 354
Weiss, E. P., Racette, S. B., Villareal, D. T., Fontana, L., Steger-May, K., Schechtman, K. B., Klein, S., & Holloszy, J. O. (2006) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/84.5.1033 · Cited by 353 · cited 1×
“The program was successfully used in abdominal fat distribution studies (20–22) and independently validated (13–15).”
MethodRacette, S. B., Weiss, E. P., Villareal, D. T., Arif, H., Steger-May, K., Schechtman, K. B., Fontana, L., Klein, S., & Holloszy, J. O. (2006) · The Journals of Gerontology: Series A · doi:10.1093/gerona/61.9.943 · Cited by 237
Durheim, M. T., Slentz, C. A., Bateman, L. A., Mabe, S. K., & Kraus, W. E. (2008) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.90397.2008 · Cited by 87
Cited by
Rooks, D., Praestgaard, J., Hariry, S., Laurent, D., Petricoul, O., Perry, R. G., Lach‐Trifilieff, E., & Roubenoff, R. (2017) · Journal of the American Geriatrics Society · doi:10.1111/jgs.14927 · Cited by 244
Polkey, M. I., Praestgaard, J., Berwick, A., Franssen, F. M. E., Singh, D., Steiner, M. C., Casaburi, R., Tillmann, H.-C., Lach-Trifilieff, E., Roubenoff, R., et al. (2019) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201802-0286oc · Cited by 111
“5T scanner and a Q-body coil at all sites, which allowed for intermuscular and subcutaneous lipid quantification (22).”
BackgroundThe advantages and limitations of cross-sectional body composition analysis
MacDonald, A. J., Greig, C. A., & Baracos, V. (2011) · Current Opinion in Supportive & Palliative Care · doi:10.1097/spc.0b013e32834c49eb · Cited by 101
Segmentation and quantification of adipose tissue by magnetic resonance imaging
Hu, H. H., Chen, J., & Shen, W. (2016) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-015-0498-z · Cited by 90
Gineste, C., Le Fur, Y., Vilmen, C., Le Troter, A., Pecchi, E., Cozzone, P. J., Hardeman, E. C., Bendahan, D., & Gondin, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061517 · Cited by 22
Metadata
- Authors
- Positano, V., Christiansen, T., Santarelli, M. F., Ringgaard, S., Landini, L., & Gastaldelli, A.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2009-02-25
- Volume
- 29
- Issue
- 3
- Pages
- 677-684
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2008993105
- Cited by
- 89
- References
- 7
- FWCI
- 6.23
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accurate segmentation of subcutaneous and intermuscular adipose tissue from MR images of the thigh. https://app.cochat.ai/papers/10.1002/jmri.21699
- The paper
- Positano, V., Christiansen, T., Santarelli, M. F., Ringgaard, S., Landini, L., & Gastaldelli, A. (2009). Accurate segmentation of subcutaneous and intermuscular adipose tissue from MR images of the thigh. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21699
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.