The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Effect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantification
Open accessAbstract
Purpose: To compare PRESS and STEAM MR spectroscopy for assessment of liver fat in human subjects. Materials and Methods: Single‐voxel (20 × 20 × 20 mm) PRESS and STEAM spectra were obtained at 1.5T in 49 human subjects with known or suspected fatty liver disease. PRESS and STEAM sequences were obtained with fixed TR (1500 msec) and different TE (five PRESS spectra between TE 30‐70 msec, five STEAM spectra between TE 20–60 msec). Spectra were quantified and T2 and T2‐corrected peak area were calculated by different techniques. The values were compared for PRESS and STEAM. Results: Water T2 values from PRESS and STEAM were not significantly different (P = 0.33). Fat peak T2s were 25%–50% shorter on PRESS than on STEAM (P < 0.02 for all comparisons) and there was no correlation between T2s of individual peaks. PRESS systematically overestimated the relative fat peak areas (by 7%–263%) compared to STEAM (P < 0.005 for all comparisons). The peak area given by PRESS was more dependent on the T2‐correction technique than STEAM. Conclusion: Measured liver fat depends on the MRS sequence used. Compared to STEAM, PRESS underestimates T2 values of fat, overestimates fat fraction, and provides a less consistent fat fraction estimate, probably due to J coupling effects. J. Magn. Reson. Imaging 2009;30:145–152. © 2009 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of intracellular triglyceride stores by H spectroscopy: validation in vivo
Szczepaniak, L. S., Babcock, E. E., Schick, F., Dobbins, R. L., Garg, A., Burns, D. K., McGarry, J. D., & Stein, D. T. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.276.5.e977 · Cited by 688
Quantification of liver fat using magnetic resonance spectroscopy
Thomsen, C., Becker, U., Winkler, K., Christoffersen, P., Jensen, M., & Henriksen, O. (1994) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(94)92543-7 · Cited by 332
Hwang, J.-H., Stein, D. T., Barzilai, N., Cui, M.-H., Tonelli, J., Kishore, P., & Hawkins, M. (2007) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00590.2006 · Cited by 188
Kotronen, A., Seppälä-Lindroos, A., Bergholm, R., & Yki-Järvinen, H. (2007) · Diabetologia · doi:10.1007/s00125-007-0867-x · Cited by 126
Cited by
Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
Self-citationIn vivo characterization of the liver fat 1H MR spectrum
Hamilton, G., Yokoo, T., Bydder, M., Cruite, I., Schroeder, M. E., Sirlin, C. B., & Middleton, M. S. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1622 · Cited by 520
Self-citationProton density fat‐fraction: A standardized mr‐based biomarker of tissue fat concentration
Reeder, S. B., Hu, H. H., & Sirlin, C. B. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23741 · Cited by 501
Self-citationRadiologic evaluation of nonalcoholic fatty liver disease
Lee, S. S. (2014) · World Journal of Gastroenterology · doi:10.3748/wjg.v20.i23.7392 · Cited by 426
Meisamy, S., Hines, C. D. G., Hamilton, G., Sirlin, C. B., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2011) · Radiology · doi:10.1148/radiol.10100708 · Cited by 382
Self-citation
Metadata
- Authors
- Hamilton, G., Middleton, M. S., Bydder, M., Yokoo, T., Schwimmer, J. B., Kono, Y., Patton, H. M., Lavine, J. E., & Sirlin, C. B.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2009-06-25
- Volume
- 30
- Issue
- 1
- Pages
- 145-152
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2036817457
- Cited by
- 215
- References
- 4
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantification. https://app.cochat.ai/papers/10.1002/jmri.21809
- The paper
- Hamilton, G., Middleton, M. S., Bydder, M., Yokoo, T., Schwimmer, J. B., Kono, Y., Patton, H. M., Lavine, J. E., & Sirlin, C. B. (2009). Effect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantification. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21809
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.