The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Diffusion‐weighted imaging of the liver: Comparison of navigator triggered and breathhold acquisitions
Abstract
PURPOSE: To compare a free breathing navigator triggered single shot echoplanar imaging (SS EPI) diffusion-weighted imaging (DWI) sequence with prospective acquisition correction (PACE) with a breathhold (BH) DWI sequence for liver imaging. MATERIALS AND METHODS: Thirty-four patients were evaluated with PACE-DWI and BH DWI of the liver using b-values of 0, 50, and 500 s/mm(2). There were 29 focal liver lesions in 18 patients. Qualitative evaluation was performed on a 3-point scale (1-3) by two independent observers (maximum score 9). Quantitative evaluation included estimated SNR (signal to noise ratio), lesion-to-liver contrast ratio, liver and lesion apparent diffusion coefficients (ADCs), and coefficient of variation (CV) of ADC in liver parenchyma and focal liver lesions (estimate of noise contamination in ADC). RESULTS: PACE-DWI showed significantly better image quality, higher SNR and lesion-to-liver contrast ratio when compared with BH DWI. ADCs of liver and focal lesions with both sequences were significantly correlated (r = 0.838 for liver parenchyma, and 0.904 for lesions, P < 0.0001), but lower with the BH sequence (P < 0.02). There was higher noise contamination in ADC measurement obtained with BH DWI (with a significantly higher SD and CV of ADC). CONCLUSION: The use of a navigator echo to trigger SS EPI DWI improves image quality and liver to lesion contrast, and enables a more precise ADC quantification compared with BH DWI acquisition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
Self-citationCoenegrachts, K., Delanote, J., Ter Beek, L., Haspeslagh, M., Bipat, S., Stoker, J., Van Kerkhove, F., Steyaert, L., Rigauts, H., & W Casselman, J. (2007) · The British Journal of Radiology · doi:10.1259/bjr/33156643 · Cited by 149
Cited by
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Self-citationClinical intravoxel incoherent motion and diffusion MR imaging: Past, present, and future
Iima, M., & Le Bihan, D. (2016) · Radiology · doi:10.1148/radiol.2015150244 · Cited by 498
Patel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22081 · Cited by 371
Self-citationCohen, A. D., Schieke, M. C., Hohenwalter, M. D., & Schmainda, K. M. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25109 · Cited by 105
Metadata
- Authors
- Taouli, B., Sandberg, A., Stemmer, A., Parikh, T., Wong, S., Xu, J., & Lee, V. S.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2009-08-26
- Volume
- 30
- Issue
- 3
- Pages
- 561-568
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W1995593861
- Cited by
- 167
- References
- 2
- FWCI
- 12.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffusion‐weighted imaging of the liver: Comparison of navigator triggered and breathhold acquisitions. https://app.cochat.ai/papers/10.1002/jmri.21876
- The paper
- Taouli, B., Sandberg, A., Stemmer, A., Parikh, T., Wong, S., Xu, J., & Lee, V. S. (2009). Diffusion‐weighted imaging of the liver: Comparison of navigator triggered and breathhold acquisitions. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.21876
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.