The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Prostate cancer detection with 3 T MRI: Comparison of diffusion‐weighted imaging and dynamic contrast‐enhanced MRI in combination with T2‐weighted imaging
Open accessAbstract
Purpose: To evaluate the diagnostic ability of diffusion‐weighted imaging (DWI) and dynamic contrast‐enhanced imaging (DCEI) in combination with T2‐weighted imaging (T2WI) for the detection of prostate cancer using 3 T magnetic resonance imaging (MRI) with a phased‐array body coil. Materials and Methods: Fifty‐three patients with elevated serum levels of prostate‐specific antigen (PSA) were evaluated by T2WI, DWI, and DCEI prior to needle biopsy. The obtained data from T2WI alone (protocol A), a combination of T2WI and DWI (protocol B), a combination T2WI and DCEI (protocol C), and a combination of T2WI plus DWI and DCEI (protocol D) were subjected to receiver operating characteristic (ROC) curve analysis. Results: The sensitivity, specificity, accuracy, and area under the ROC curve (Az) for region‐based analysis were: 61%, 91%, 84%, and 0.8415, respectively, in protocol A; 76%, 94%, 90%, and 0.8931, respectively, in protocol B; 77%, 93%, 89%, and 0.8655, respectively, in protocol C; and 81%, 96%, 92%, and 0.8968, respectively in protocol D. ROC analysis revealed significant differences between protocols A and B (P = 0.0008) and between protocols A and D (P = 0.0004). Conclusion: In patients with elevated PSA levels the combination of T2WI, DWI, DCEI using 3 T MRI may be a reasonable approach for the detection of prostate cancer. J. Magn. Reson. Imaging 2010;31:625–631. © 2010 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
Cited by
ESUR prostate MR guidelines 2012
Barentsz, J. O., Richenberg, J., Clements, R., Choyke, P., Verma, S., Villeirs, G., Rouviere, O., Logager, V., & Fütterer, J. J. (2012) · European Radiology · doi:10.1007/s00330-011-2377-y · Cited by 2,438
Siddiqui, M. M., Rais-Bahrami, S., Turkbey, B., George, A. K., Rothwax, J., Shakir, N., Okoro, C., Raskolnikov, D., Parnes, H. L., Linehan, W. M., et al. (2015) · JAMA · doi:10.1001/jama.2014.17942 · Cited by 1,505
Evaluation of prostate segmentation algorithms for mri: The promise12 challenge
Litjens, G., Toth, R., van de Ven, W., Hoeks, C., Kerkstra, S., van Ginneken, B., Vincent, G., Guillard, G., Birbeck, N., Zhang, J., et al. (2014) · Medical Image Analysis · doi:10.1016/j.media.2013.12.002 · Cited by 857
Accuracy of Multiparametric MRI for Prostate Cancer Detection: A Meta-Analysis
de Rooij, M., Hamoen, E. H. J., Fütterer, J. J., Barentsz, J. O., & Rovers, M. M. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.11046 · Cited by 470
Computer-Aided Detection of Prostate Cancer in MRI
Litjens, G., Debats, O., Barentsz, J., Karssemeijer, N., & Huisman, H. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2303821 · Cited by 447
Vargas, H. A., Akin, O., Franiel, T., Mazaheri, Y., Zheng, J., Moskowitz, C., Udo, K., Eastham, J., & Hricak, H. (2011) · Radiology · doi:10.1148/radiol.11102066 · Cited by 402
Moldovan, P. C., Van den Broeck, T., Sylvester, R., Marconi, L., Bellmunt, J., van den Bergh, R. C. N., Bolla, M., Briers, E., Cumberbatch, M. G., Fossati, N., et al. (2017) · European Urology · doi:10.1016/j.eururo.2017.02.026 · Cited by 391
Fehr, D., Veeraraghavan, H., Wibmer, A., Gondo, T., Matsumoto, K., Vargas, H. A., Sala, E., Hricak, H., & Deasy, J. O. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1505935112 · Cited by 382
Transfer learning techniques for medical image analysis: A review
Kora, P., Ooi, C. P., Faust, O., Raghavendra, U., Gudigar, A., Chan, W. Y., Meenakshi, K., Swaraja, K., Plawiak, P., & Rajendra Acharya, U. (2022) · Biocybernetics and Biomedical Engineering · doi:10.1016/j.bbe.2021.11.004 · Cited by 367
Hamoen, E. H. J., de Rooij, M., Witjes, J. A., Barentsz, J. O., & Rovers, M. M. (2015) · European Urology · doi:10.1016/j.eururo.2014.10.033 · Cited by 316
Hambrock, T., Hoeks, C., Hulsbergen-van de Kaa, C., Scheenen, T., Fütterer, J., Bouwense, S., van Oort, I., Schröder, F., Huisman, H., & Barentsz, J. (2012) · European Urology · doi:10.1016/j.eururo.2011.08.042 · Cited by 307
Metadata
- Authors
- Kitajima, K., Kaji, Y., Fukabori, Y., Yoshida, K., Suganuma, N., & Sugimura, K.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2010-02-25
- Volume
- 31
- Issue
- 3
- Pages
- 625-631
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2059559115
- Cited by
- 203
- References
- 1
- FWCI
- 18.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.