Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 447

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Computer-Aided Detection of Prostate Cancer in MRI

Open access
Litjens, Geert, Debats, Oscar, Barentsz, Jelle, Karssemeijer, Nico, Huisman, Henkjan·2014·IEEE Transactions on Medical Imaging

Abstract

Prostate cancer is one of the major causes of cancer death for men in the western world. Magnetic resonance imaging (MRI) is being increasingly used as a modality to detect prostate cancer. Therefore, computer-aided detection of prostate cancer in MRI images has become an active area of research. In this paper we investigate a fully automated computer-aided detection system which consists of two stages. In the first stage, we detect initial candidates using multi-atlas-based prostate segmentation, voxel feature extraction, classification and local maxima detection. The second stage segments the candidate regions and using classification we obtain cancer likelihoods for each candidate. Features represent pharmacokinetic behavior, symmetry and appearance, among others. The system is evaluated on a large consecutive cohort of 347 patients with MR-guided biopsy as the reference standard. This set contained 165 patients with cancer and 182 patients without prostate cancer. Performance evaluation is based on lesion-based free-response receiver operating characteristic curve and patient-based receiver operating characteristic analysis. The system is also compared to the prospective clinical performance of radiologists. Results show a sensitivity of 0.42, 0.75, and 0.89 at 0.1, 1, and 10 false positives per normal case. In clinical workflow the system could potentially be used to improve the sensitivity of the radiologist. At the high specificity reading setting, which is typical in screening situations, the system does not perform significantly different from the radiologist and could be used as an independent second reader instead of a second radiologist. Furthermore, the system has potential in a first-reader setting.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tmi.2014.2303821

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

See all 447

Metadata

Authors
Litjens, G., Debats, O., Barentsz, J., Karssemeijer, N., & Huisman, H.
Venue
IEEE Transactions on Medical Imaging
Published
2014-05
Volume
33
Issue
5
Pages
1083-1092
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W2107030642
Cited by
447
References
26
FWCI
21.66
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Computer-Aided Detection of Prostate Cancer in MRI. https://app.cochat.ai/papers/10.1109/tmi.2014.2303821
The paper
Litjens, G., Debats, O., Barentsz, J., Karssemeijer, N., & Huisman, H. (2014). Computer-Aided Detection of Prostate Cancer in MRI. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2014.2303821

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.