Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 159

The DOI matches its Crossref record.

International reproducibility of single breathhold T2* MR for cardiac and liver iron assessment among five thalassemia centers

Open access
Kirk, Paul, He, Taigang, Anderson, Lisa J., Roughton, Michael, Tanner, Mark A., Lam, Wynnie W.M., Au, Wing Y., Chu, Winnie C.W., Chan, Godfrey, Galanello, Renzo, Matta, Gildo, Fogel, Mark, Cohen, Alan R., Tan, Ru San, Chen, Kevin, Ng, Ivy, Lai, Angie, Fucharoen, Suthat, Laothamata, Jiraporn, Chuncharunee, Suporn, Jongjirasiri, Sutipong, Firmin, David N., Smith, Gillian C., Pennell, Dudley J. · 2010 · Journal of Magnetic Resonance Imaging

Abstract

Purpose: To examine the reproducibility of the single breathhold T2* technique from different scanners, after installation of standard methodology in five international centers. Materials and Methods: Up to 10 patients from each center were scanned twice locally for local interstudy reproducibility of heart and liver T2*, and then flown to a central MR facility to be rescanned on a reference scanner for intercenter reproducibility. Interobserver reproducibility for all scans was also assessed. Results: Of the 49 patients scanned, the intercenter reproducibility for T2* was 5.9% for the heart and 5.8% for the liver. Local interstudy reproducibility for T2* was 7.4% for the heart and 4.6% for the liver. Interobserver reproducibility for T2* was 5.4% for the heart and 4.4% for the liver. Conclusion: These data indicate that T2* MR may be developed into a widespread test for tissue siderosis providing that well‐defined and approved imaging and analysis techniques are used. J. Magn. Reson. Imaging 2010;32:315–319. © 2010 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.22245

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 159

Metadata

Authors
Kirk, P., He, T., Anderson, L. J., Roughton, M., Tanner, M. A., Lam, W. W. M., Au, W. Y., Chu, W. C. W., Chan, G., Galanello, R., Matta, G., Fogel, M., Cohen, A. R., Tan, R. S., Chen, K., Ng, I., Lai, A., Fucharoen, S., Laothamata, J., Chuncharunee, S., Jongjirasiri, S., Firmin, D. N., Smith, G. C., & Pennell, D. J.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2010-07-22
Volume
32
Issue
2
Pages
315-319
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2170036364
Cited by
159
References
0
FWCI
5.18
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: International reproducibility of single breathhold T2* MR for cardiac and liver iron assessment among five thalassemia centers. https://app.cochat.ai/papers/10.1002/jmri.22245
The paper
Kirk, P., He, T., Anderson, L. J., Roughton, M., Tanner, M. A., Lam, W. W. M., Au, W. Y., Chu, W. C. W., Chan, G., Galanello, R., Matta, G., Fogel, M., Cohen, A. R., Tan, R. S., Chen, K., Ng, I., Lai, A., Fucharoen, S., Laothamata, J., . . . Pennell, D. J. (2010). International reproducibility of single breathhold T2* MR for cardiac and liver iron assessment among five thalassemia centers. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22245

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.