CoChat

Dual‐temporal resolution dynamic contrast‐enhanced MRI protocol for blood–brain barrier permeability measurement in enhancing multiple sclerosis lesions

Open access
Jelescu, I.O., Leppert, I.R., Narayanan, S., Araújo, D., Arnold, D.L., Pike, G.B. · 2011 · Journal of Magnetic Resonance Imaging
Cited by 55

The DOI matches its Crossref record.

Abstract

Purpose: To design a more accurate and reproducible technique for the measurement of blood–brain barrier (BBB) permeability in gadolinium‐enhancing multiple sclerosis (MS) lesions. Materials and Methods: Four MS patients were scanned using a new dynamic contrast‐enhanced (DCE)‐magnetic resonance imaging (MRI) protocol based on an uninterrupted two‐part acquisition consisting of an initial part at high temporal and low spatial resolutions and a second part at low temporal and high spatial resolutions. The method preserves both the high spatial resolution needed for the often small size of lesions and the high temporal resolution required during the first minute after injection to sufficiently sample the first‐pass bolus. Simulations compared the performance of this new protocol with the conventional one at low temporal and high spatial resolutions throughout. Results: The BBB permeability estimates changed by up to 33% between the two protocols. The new protocol led to simulated error on K trans of 7%–10%, versus 7%–30% with the conventional protocol, and was more robust with respect to offsets between acquisition and injection start times, differences in shape of the first‐pass peak, and permeability values. Conclusion: The dual‐temporal resolution protocol produces improved BBB permeability estimates and provides a more complete view of active inflammatory MS lesion pathology. J. Magn. Reson. Imaging 2011;33:1291–1300. © 2011 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.22565

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 55

Metadata

Authors
Jelescu, I. O., Leppert, I. R., Narayanan, S., Araújo, D., Arnold, D. L., & Pike, G. B.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2011-05-17
Volume
33
Issue
6
Pages
1291-1300
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2068034417
Cited by
55
References
0
FWCI
2.07
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dual‐temporal resolution dynamic contrast‐enhanced MRI protocol for blood–brain barrier permeability measurement in enhancing multiple sclerosis lesions. https://app.cochat.ai/papers/10.1002/jmri.22565
The paper
Jelescu, I. O., Leppert, I. R., Narayanan, S., Araújo, D., Arnold, D. L., & Pike, G. B. (2011). Dual‐temporal resolution dynamic contrast‐enhanced MRI protocol for blood–brain barrier permeability measurement in enhancing multiple sclerosis lesions. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22565

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.