Effect of scanner in longitudinal studies of brain volume changes
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Purpose: To evaluate the effects of drift in scanner hardware and inter‐scanner variability on global and regional brain volume changes using longitudinal data obtained on two scanners of the exact same model. Materials and Methods: A total of 208 subjects (70 females and 138 males, mean age = 56.5 ± 10.1 years) were scanned twice, at an interval of approximately 2 years (mean interval = 1.9 ± 0.15 years), using two 3.0 Tesla (T) scanners of the exact same model. The subjects were divided into four groups according to the combination of scanners used. The effects of scanner drift and inter‐scanner variability on global and regional brain volume changes were evaluated using voxel‐based morphometry (VBM) and structural image evaluation using normalization of atrophy (SIENA). Results: The mean whole brain volume calculated using VBM increased by 17.2 ± 29.3 mL, and the changes were significantly different between groups. The mean percentage brain volume change (PBVC) calculated using SIENA was −0.46 ± 0.71 %, and did not differ between groups. VBM showed several regions with a significant increase or decrease in volume; however, SIENA showed that edge displacement values were negative in most regions. Conclusion: Even with scanners of the exact same model, scanner drift, and inter‐scanner variability can cancel out actual longitudinal brain volume change. SIENA, which corrects for differences in imaging geometry using the outer skull surface for both time points, can reduce the effects of scanner drift and inter‐scanner variability on longitudinal morphometric results. J. Magn. Reson. Imaging 2011;. © 2011 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jenkinson, M., Bannister, P., Brady, M., & Smith, S. (2002) · NeuroImage · doi:10.1006/nimg.2002.1132 · Cited by 11,888
A fast diffeomorphic image registration algorithm
Ashburner, J. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.07.007 · Cited by 8,122
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
Nonparametric permutation tests for functional neuroimaging: A primer with examples
Nichols, T. E., & Holmes, A. P. (2002) · Human Brain Mapping · doi:10.1002/hbm.1058 · Cited by 6,256
A nonparametric method for automatic correction of intensity nonuniformity in MRI data
Sled, J. G., Zijdenbos, A. P., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.668698 · Cited by 4,731
A Voxel-Based Morphometric Study of Ageing in 465 Normal Adult Human Brains
Good, C. D., Johnsrude, I. S., Ashburner, J., Henson, R. N. A., Friston, K. J., & Frackowiak, R. S. J. (2001) · NeuroImage · doi:10.1006/nimg.2001.0786 · Cited by 4,561
The Alzheimer’s disease neuroimaging initiative (ADNI): MRI methods
Jack, C. R., Bernstein, M. A., Fox, N. C., Thompson, P., Alexander, G., Harvey, D., Borowski, B., Britson, P. J., L. Whitwell, J., Ward, C., et al. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21049 · Cited by 4,347
Han, X., Jovicich, J., Salat, D., van der Kouwe, A., Quinn, B., Czanner, S., Busa, E., Pacheco, J., Albert, M., Killiany, R., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.02.051 · Cited by 1,508
Normative estimates of cross-sectional and longitudinal brain volume decline in aging and AD
Fotenos, A. F., Snyder, A. Z., Girton, L. E., Morris, J. C., & Buckner, R. L. (2005) · Neurology · doi:10.1212/01.wnl.0000154530.72969.11 · Cited by 579
Consistent neuroanatomical age-related volume differences across multiple samples
Walhovd, K. B., Westlye, L. T., Amlien, I., Espeseth, T., Reinvang, I., Raz, N., Agartz, I., Salat, D. H., Greve, D. N., Fischl, B., et al. (2011) · Neurobiology of Aging · doi:10.1016/j.neurobiolaging.2009.05.013 · Cited by 506
Cited by
Within-subject template estimation for unbiased longitudinal image analysis
Reuter, M., Schmansky, N. J., Rosas, H. D., & Fischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.084 · Cited by 2,356
Harmonization of cortical thickness measurements across scanners and sites
Fortin, J.-P., Cullen, N., Sheline, Y. I., Taylor, W. D., Aselcioglu, I., Cook, P. A., Adams, P., Cooper, C., Fava, M., McGrath, P. J., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.11.024 · Cited by 1,580
“…subject positioning, and longitudinal drift have been long understood to increase bias and variance in the measurement of brain volume changes (Takao et al., 2011), regional cortical thickness (Han et al., 2006), voxel-based morphometry (Takao et al., 2014), and structural, functional, and…”
BackgroundMarcus, D. S., Fotenos, A. F., Csernansky, J. G., Morris, J. C., & Buckner, R. L. (2010) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.2009.21407 · Cited by 631
Pomponio, R., Erus, G., Habes, M., Doshi, J., Srinivasan, D., Mamourian, E., Bashyam, V., Nasrallah, I. M., Satterthwaite, T. D., Fan, Y., et al. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2019.116450 · Cited by 524
Longitudinal ComBat: A method for harmonizing longitudinal multi-scanner imaging data
Beer, J. C., Tustison, N. J., Cook, P. A., Davatzikos, C., Sheline, Y. I., Shinohara, R. T., & Linn, K. A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117129 · Cited by 319
Metadata
- Authors
- Takao, H., Hayashi, N., & Ohtomo, K.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2011-06-20
- Volume
- 34
- Issue
- 2
- Pages
- 438-444
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2017244551
- Cited by
- 118
- References
- 13
- FWCI
- 2.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of scanner in longitudinal studies of brain volume changes. https://app.cochat.ai/papers/10.1002/jmri.22636
- The paper
- Takao, H., Hayashi, N., & Ohtomo, K. (2011). Effect of scanner in longitudinal studies of brain volume changes. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.22636
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.