Reproducibility of hepatic fat fraction measurement by magnetic resonance imaging

Mashhood, Arian, Railkar, Radha, Yokoo, Takeshi, Levin, Yakir, Clark, Lisa, Fox‐Bosetti, Sabrina, Middleton, Michael S., Riek, Jonathan, Kauh, Eunkyung, Dardzinski, Bernard J., Williams, Donald, Sirlin, Claude, Shire, Norah J. · 2013 · Journal of Magnetic Resonance Imaging
Cited by 74

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

Purpose: To evaluate the reproducibility of magnetic resonance imaging (MRI)‐determined hepatic fat fraction (%) across imaging sites with different magnet types and field strength. Reproducibility among MRI platforms is unclear, even though evaluating hepatic fat fractions (FFs) using MRI‐based methods is accurate against MR spectroscopy. Materials and Methods: Overweight subjects were recruited to undergo eight MRI examinations at five imaging centers with a range of magnet manufacturers and field strengths (1.5 and 3 T). FFs were estimated in liver and in fat‐emulsion phantoms using three methods: 1) dual‐echo images without correction (nominally out‐of‐phase [OP] and in‐phase [IP]); 2) dual‐dual‐echo images (two sequences) with T2* correction (nominally OP/IP and IP/IP); and 3) six‐echo images with spectral model and T2* correction, at sequential alternating OP and IP echo times (Methods 1, 2, and 3, respectively). Results: Ten subjects were recruited. For Methods 1, 2, and 3, respectively, hepatic FF ranged from −2.5 to 27.0, 1.9 to 29.6, and 1.3 to 34.4%. Intraclass correlation coefficients were 0.85, 0.89, and 0.91 for each method, and within‐subject coefficients of variation were 18.5, 9.9, and 10.3%, respectively. Mean phantom FFs derived by Methods 2 and 3 were comparable to the known FF for each phantom. Method 1 underestimated phantom FF. Conclusion: Methods 2 and 3 accurately assess FF. Strong reproducibility across magnet type and strength render them suitable for use in multicenter trials and longitudinal assessments. J. Magn. Reson. Imaging 2013;37:1359–1370. © 2012 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.23928

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

Metadata

Authors
Mashhood, A., Railkar, R., Yokoo, T., Levin, Y., Clark, L., Fox‐Bosetti, S., Middleton, M. S., Riek, J., Kauh, E., Dardzinski, B. J., Williams, D., Sirlin, C., & Shire, N. J.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2012-11-21
Volume
37
Issue
6
Pages
1359-1370
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W2039618459
Cited by
74
References
13
FWCI
4.23
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›