CoChat

Morphology and function: MR pineal volume and melatonin level in human saliva are correlated

Liebrich, Luisa‐Sophie, Schredl, Michael, Findeisen, Peter, Groden, Christoph, Bumb, Jan Malte, Nölte, Ingo S. · 2014 · Journal of Magnetic Resonance Imaging
Cited by 50

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Purpose: To investigate the relation between circadian saliva melatonin levels and pineal volume as determined by MRI. Plasma melatonin levels follow a circadian rhythm with a high interindividual variability. Materials and Methods: In 103 healthy individuals saliva melatonin levels were determined at four time points within 24 h and MRI was performed once (3.0 Tesla, including three‐dimensional T2 turbo spin echo [3D‐T2‐TSE], susceptibility‐weighted imaging [SWI]). Pineal volume as well as cyst volume were assessed from multiplanar reconstructed 3D‐T2‐TSE images. Pineal calcification volume tissue was determined on SWI. To correct for hormonal inactive pineal tissue, cystic and calcified areas were excluded. Sleep quality was assessed with the Landeck Inventory for sleep quality disturbance. Results: Solid and uncalcified pineal volume correlated to melatonin maximum (r = 0.28; P < 0.05) and area under the curve (r = 0.29; P < 0.05). Of interest, solid and uncalcified pineal volume correlated negatively with the sleep rhythm disturbances subscore (r = −0.17; P < 0.05) despite a very homogenous population. Conclusion: Uncalcified solid pineal tissue measured by 3D‐T2‐TSE and SWI is related to human saliva melatonin levels. The analysis of the sleep quality and pineal volume suggests a linkage between better sleep quality and hormonal active pineal tissue. J. Magn. Reson. Imaging 2014;40:966–971. © 2013 Wiley Periodicals, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.24449

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 50

Metadata

Authors
Liebrich, L., Schredl, M., Findeisen, P., Groden, C., Bumb, J. M., & Nölte, I. S.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2013-11-08
Volume
40
Issue
4
Pages
966-971
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W1944399564
Cited by
50
References
2
FWCI
1.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Morphology and function: MR pineal volume and melatonin level in human saliva are correlated. https://app.cochat.ai/papers/10.1002/jmri.24449
The paper
Liebrich, L., Schredl, M., Findeisen, P., Groden, C., Bumb, J. M., & Nölte, I. S. (2014). Morphology and function: MR pineal volume and melatonin level in human saliva are correlated. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.24449

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.