The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Automatic and quantitative assessment of regional muscle volume by multi‐atlas segmentation using whole‐body water–fat MRI
Abstract
Purpose: To develop and demonstrate a rapid whole‐body magnetic resonance imaging (MRI) method for automatic quantification of total and regional skeletal muscle volume. Materials and Methods: The method was based on a multi‐atlas segmentation of intensity corrected water–fat separated image volumes. Automatic lean muscle tissue segmentations were achieved by nonrigid registration of atlas datasets with 10 different manually segmented muscle groups. Ten subjects scanned at 1.5 T and 3.0 T were used as atlases, initial validation and optimization. Further validation used 11 subjects scanned at 3.0 T. The automated and manual segmentations were compared using intraclass correlation, true positive volume fractions, and delta volumes. Results: For the 1.5 T datasets, the intraclass correlation, true positive volume fractions (mean ± standard deviation, SD), and delta volumes (mean ± SD) were 0.99, 0.91 ± 0.02, −0.10 ± 0.70L (whole body), 0.99, 0.93 ± 0.02, 0.01 ± 0.07L (left anterior thigh), and 0.98, 0.80 ± 0.07, −0.08 ± 0.15L (left abdomen). The corresponding values at 3.0 T were 0.97, 0.92 ± 0.03, −0.17 ± 1.37L (whole body), 0.99, 0.93 ± 0.03, 0.03 ± 0.08L (left anterior thigh), and 0.89, 0.90 ± 0.04, −0.03 ± 0.42L (left abdomen). The validation datasets showed similar results. Conclusion: The method accurately quantified the whole‐body skeletal muscle volume and the volume of separate muscle groups independent of field strength and image resolution. J. Magn. Reson. Imaging 2015;41:1558–1569. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sarcopenia: European consensus on definition and diagnosis
Cruz-Jentoft, A. J., Baeyens, J. P., Bauer, J. M., Boirie, Y., Cederholm, T., Landi, F., Martin, F. C., Michel, J.-P., Rolland, Y., Schneider, S. M., et al. (2010) · Age and Ageing · doi:10.1093/ageing/afq034 · Cited by 11,601
Cortical Surface-Based Analysis
Dale, A. M., Fischl, B., & Sereno, M. I. (1999) · NeuroImage · doi:10.1006/nimg.1998.0395 · Cited by 10,910
Fielding, R. A., Vellas, B., Evans, W. J., Bhasin, S., Morley, J. E., Newman, A. B., Abellan van Kan, G., Andrieu, S., Bauer, J., Breuille, D., et al. (2011) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2011.01.003 · Cited by 3,256
Image matching as a diffusion process: an analogy with maxwell’s demons
Thirion, J.-P. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(98)80022-4 · Cited by 2,445
Emery, A. E. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07815-7 · Cited by 1,667
Cited by
Multi-atlas segmentation of biomedical images: A survey
Iglesias, J. E., & Sabuncu, M. R. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.06.012 · Cited by 667
Advanced Body Composition Assessment: From Body Mass Index to Body Composition Profiling
Borga, M., West, J., Bell, J. D., Harvey, N. C., Romu, T., Heymsfield, S. B., & Dahlqvist Leinhard, O. (2018) · Journal of Investigative Medicine · doi:10.1136/jim-2018-000722 · Cited by 606
Self-citationHeymsfield, S. B., Gonzalez, M. C., Lu, J., Jia, G., & Zheng, J. (2015) · Proceedings of the Nutrition Society · doi:10.1017/s0029665115000129 · Cited by 483
Kuriyan, R. (2018) · Indian Journal of Medical Research · doi:10.4103/ijmr.ijmr_1777_18 · Cited by 384
Big Data, Big Knowledge: Big Data for Personalized Healthcare
Viceconti, M., Hunter, P., & Hose, R. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2406883 · Cited by 345
Metadata
- Authors
- Karlsson, A., Rosander, J., Romu, T., Tallberg, J., Grönqvist, A., Borga, M., & Dahlqvist Leinhard, O.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2014-08-11
- Volume
- 41
- Issue
- 6
- Pages
- 1558-1569
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2109154320
- Cited by
- 219
- References
- 5
- FWCI
- 11.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.