Quantifying the influence of respiration and cardiac pulsations on cerebrospinal fluid dynamics using real‐time phase‐contrast MRI
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Purpose: To validate a real‐time phase contrast magnetic resonance imaging (RT‐PCMRI) sequence in a controlled phantom model, and to quantify the relative contributions of respiration and cardiac pulsations on cerebrospinal fluid (CSF) velocity at the level of the foramen magnum (FM). Materials and Methods: To validate the 3T MRI techniques, in vitro studies used a realistic model of the spinal subarachnoid space driven by pulsatile flow waveforms mimicking the respiratory and cardiac components of CSF flow. Subsequently, CSF flow was measured continuously during 1‐minute RT‐PCMRI acquisitions at the FM while healthy subjects (N = 20) performed natural breathing, deep breathing, breath‐holding, and coughing. Conventional cardiac‐gated PCMRI was obtained for comparison. A frequency domain power ratio analysis determined the relative contribution of respiration versus cardiac ([r/c]) components of CSF velocity. Results: In vitro studies demonstrating the accuracy of RT‐PCMRI within 5% of input values showed that conventional PCMRI measures only the cardiac component of CSF velocity (0.42 ± 0.02 cm/s), averages out respiratory effects, and underestimates the magnitude of CSF velocity (0.96 ± 0.07 cm/s). In vivo RT‐PCMRI measurements indicated the ratio of respiratory to cardiac velocity pulsations averaged over all subjects as [r/c = 0.14 ± 0.27] and [r/c = 0.40 ± 0.47] for natural and deep breathing, respectively. During coughing, the peak CSF velocity increased by a factor of 2.27 ± 1.40. Conclusion: RT‐PCMRI can noninvasively measure instantaneous CSF velocity driven by cardiac pulsations, respiration, and coughing in real time. A comparable contribution of respiration and cardiac pulsations on CSF velocity was found during deep breathing but not during natural breathing. Level of Evidence: 1 Technical Efficacy: Stage 1 J. MAGN. RESON. IMAGING 2017;46:431–439
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Iliff, J. J., Wang, M., Liao, Y., Plogg, B. A., Peng, W., Gundersen, G. A., Benveniste, H., Vates, G. E., Deane, R., Goldman, S. A., et al. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3003748 · Cited by 5,824
Sleep Drives Metabolite Clearance from the Adult Brain
Xie, L., Kang, H., Xu, Q., Chen, M. J., Liao, Y., Thiyagarajan, M., O’Donnell, J., Christensen, D. J., Nicholson, C., Iliff, J. J., et al. (2013) · Science · doi:10.1126/science.1241224 · Cited by 5,411
Nedergaard, M. (2013) · Science · doi:10.1126/science.1240514 · Cited by 718
Inspiration is the major regulator of human CSF flow.
Dreha-Kulaczewski, S., Joseph, A. A., Merboldt, K.-D., Ludwig, H.-C., Gärtner, J., & Frahm, J. (2015) · The Journal of Neuroscience · doi:10.1523/jneurosci.3246-14.2015 · Cited by 405
Human brain motion and cerebrospinal fluid circulation demonstrated with MR velocity imaging.
Feinberg, D. A., & Mark, A. S. (1987) · Radiology · doi:10.1148/radiology.163.3.3575734 · Cited by 379
Aging Effects on Cerebral Blood and Cerebrospinal Fluid Flows
Stoquart-ElSankari, S., Balédent, O., Gondry-Jouet, C., Makki, M., Godefroy, O., & Meyer, M.-E. (2007) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600462 · Cited by 280 · cited 1×
“This coupling is known to depend on cerebral vascularization,(31) age, and sex of the subjects.(32,34) Further investigations are needed to fully quantify the influence of these effects on instantaneous CSF flow magnitude and directionality along the spine and in the cranial cavity.”
BackgroundNitz, W. R., Bradley, W. G., Watanabe, A. S., Lee, R. R., Burgoyne, B., O'Sullivan, R. M., & Herbst, M. D. (1992) · Radiology · doi:10.1148/radiology.183.2.1561340 · Cited by 273
Quantifying the effect of posture on intracranial physiology in humans by MRI flow studies
Alperin, N., Lee, S. H., Sivaramakrishnan, A., & Hushek, S. G. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20427 · Cited by 218
Influence of respiration on cerebrospinal fluid movement using magnetic resonance spin labeling
Yamada, S., Miyazaki, M., Yamashita, Y., Ouyang, C., Yui, M., Nakahashi, M., Shimizu, S., Aoki, I., Morohoshi, Y., & McComb, J. G. (2013) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-10-36 · Cited by 208
CSF Flow in the Brain in the Context of Normal Pressure Hydrocephalus
Bradley, W. G. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4124 · Cited by 202
Williams, B. (1981) · Acta Neurochirurgica · doi:10.1007/bf01411198 · Cited by 163
Williams, B. (1981) · Acta Neurochirurgica · doi:10.1007/bf01407124 · Cited by 163
Chen, L., Beckett, A., Verma, A., & Feinberg, D. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.07.073 · Cited by 140 · cited 4×
“A recent real-time (RT) PCMRI study measured CSF velocity and directionality due to cardiac and breathing effects in the brain and basal cisterns over a 30-second period.(17) However, this previous study did not assess the accuracy of RT CSF flow measurements and these measurements were not made in the spinal subarach…”
BackgroundMethodResultInfluentialPUBS: Pulsatility‐based segmentation of lumens conducting non‐steady flow
Alperin, N. J., & Lee, S. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10455 · Cited by 118
Wang, S.-Z., Li, S., Xu, X.-Y., Lin, G.-P., Shao, L., Zhao, Y., & Wang, T. H. (2010) · The Journal of Alternative and Complementary Medicine · doi:10.1089/acm.2009.0577 · Cited by 116
Detection of a relation between respiration and CSF pulsation with an echoplanar technique
Klose, U., Strik, C., Kiefer, C., & Grodd, W. (2000) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(200004)11:4<438::aid-jmri12>3.0.co;2-o · Cited by 89
Pahlavian, S. H., Yiallourou, T. I., Tubbs, R. S., Bunck, A. C., Loth, F., Goodin, M. S., Raisee, M., & Martin, B. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0091888 · Cited by 73
Self-citationCerebrospinal fluid hydrodynamics in type I Chiari malformation
Shaffer, N., Martin, B. A., & Loth, F. (2011) · Neurological Research · doi:10.1179/016164111x12962202723805 · Cited by 72
Self-citationSankari, S. E., Balédent, O., Pesch, V. V., Sindic, C., de Broqueville, Q., & Duprez, T. P. J. (2013) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2013.95 · Cited by 64
Daners, M. S., Knobloch, V., Soellinger, M., Boesiger, P., Seifert, B., Guzzella, L., & Kurtcuoglu, V. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037502 · Cited by 58 · cited 1×
“This coupling is known to depend on cerebral vascularization,(31) age, and sex of the subjects.(32,34) Further investigations are needed to fully quantify the influence of these effects on instantaneous CSF flow magnitude and directionality along the spine and in the cranial cavity.”
BackgroundLin, H., Bender, J. A., Ding, Y., Chung, Y., Hinton, A. M., Pennell, M. L., Whitehead, K. K., Raman, S. V., & Simonetti, O. P. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23273 · Cited by 52
Alperin, N. J., Lee, S. H., & Bagci, A. M. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24882 · Cited by 40
Pahlavian, S. H., Bunck, A. C., Thyagaraj, S., Giese, D., Loth, F., Hedderich, D. M., Kröger, J. R., & Martin, B. A. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1602-x · Cited by 35
Self-citationTheoretical aspects of the attenuation of pressure pulses within cerebrospinal-fluid pathways
Lockey, M. P., Poots, G., & Williams, B. (1975) · Medical & Biological Engineering & Computing · doi:10.1007/bf02478090 · Cited by 31 · cited 1×
“This is likely due to respiration pressure dynamics that are transmitted to the thoracic and epidural veins lining the spine.(30) This directionality finding is consistent with previous observations made in the cranial cavity and lateral ventricles using other RT-PCMRI techniques.”
ResultKao, Y., Guo, W., Liou, A. J.-K., Hsiao, Y.-H., & Chou, C. (2007) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.07.001 · Cited by 30
Pahlavian, S. H., Bunck, A. C., Loth, F., Tubbs, R. S., Yiallourou, T. I., Kröger, J. R., Heindel, W. L., & Martin, B. A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029699 · Cited by 29
Self-citation
Cited by
The glymphatic hypothesis: the theory and the evidence
Hladky, S. B., & Barrand, M. A. (2022) · Fluids and Barriers of the CNS · doi:10.1186/s12987-021-00282-z · Cited by 240
Hladky, S. B., & Barrand, M. A. (2018) · Fluids and Barriers of the CNS · doi:10.1186/s12987-018-0113-6 · Cited by 206
Coles, J. A., Myburgh, E., Brewer, J. M., & McMenamin, P. G. (2017) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2017.05.002 · Cited by 123
“There is agreement that inspiration causes an upward movement of CSF (from the fourth ventricle towards the third) but, confusingly, while Dreha-Kulakewski et al. 2017 find that this movement is greater than that caused by cardiac pulsations, Yildiz et al., 2017, find that it is smaller.”
Harnessing cerebrospinal fluid circulation for drug delivery to brain tissues
Naseri Kouzehgarani, G., Feldsien, T., Engelhard, H. H., Mirakhur, K. K., Phipps, C., Nimmrich, V., Clausznitzer, D., & Lefebvre, D. R. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.03.002 · Cited by 95
Metadata
- Authors
- Yildiz, S., Thyagaraj, S., Jin, N., Zhong, X., Heidari Pahlavian, S., Martin, B. A., Loth, F., Oshinski, J., & Sabra, K. G.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2017-02-02
- Volume
- 46
- Issue
- 2
- Pages
- 431-439
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2584346819
- Cited by
- 179
- References
- 26
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.