The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Low‐cost and portable MRI
Open accessAbstract
Research in MRI technology has traditionally expanded diagnostic benefit by developing acquisition techniques and instrumentation to enable MRI scanners to "see more." This typically focuses on improving MRI's sensitivity and spatiotemporal resolution, or expanding its range of biological contrasts and targets. In complement to the clear benefits achieved in this direction, extending the reach of MRI by reducing its cost, siting, and operational burdens also directly benefits healthcare by increasing the number of patients with access to MRI examinations and tilting its cost–benefit equation to allow more frequent and varied use. The introduction of low‐cost, and/or truly portable scanners, could also enable new point‐of‐care and monitoring applications not feasible for today's scanners in centralized settings. While cost and accessibility have always been considered, we have seen tremendous advances in the speed and spatial‐temporal capabilities of general‐purpose MRI scanners and quantum leaps in patient comfort (such as magnet length and bore diameter), but only modest success in the reduction of cost and siting constraints. The introduction of specialty scanners (eg, extremity, brain‐only, or breast‐only scanners) have not been commercially successful enough to tilt the balance away from the prevailing model: a general‐purpose scanner in a centralized healthcare location. Portable MRI scanners equivalent to their counterparts in ultrasound or even computed tomography have not emerged and MR monitoring devices exist only in research laboratories. Nonetheless, recent advances in hardware and computational technology as well as burgeoning markets for MRI in the developing world has created a resurgence of interest in the topic of low‐cost and accessible MRI. This review examines the technical forces and trade‐offs that might facilitate a large step forward in the push to "jail‐break" MRI from its centralized location in healthcare and allow it to reach larger patient populations and achieve new uses. Level of Evidence: 5 Technical Efficacy Stage: 6 J. Magn. Reson. Imaging 2019. J. Magn. Reson. Imaging 2020;52:686–696.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303
Moore, C. L., & Copel, J. A. (2011) · New England Journal of Medicine · doi:10.1056/nejmra0909487 · Cited by 1,788
Design of permanent multipole magnets with oriented rare earth cobalt material
Halbach, K. (1980) · Nuclear Instruments and Methods · doi:10.1016/0029-554x(80)90094-4 · Cited by 1,532
Miglioretti, D. L., Johnson, E., Williams, A., Greenlee, R. T., Weinmann, S., Solberg, L. I., Feigelson, H. S., Roblin, D., Flynn, M. J., Vanneman, N., et al. (2013) · JAMA Pediatrics · doi:10.1001/jamapediatrics.2013.311 · Cited by 1,476
Smith-Bindman, R., Miglioretti, D. L., Johnson, E., Lee, C., Feigelson, H. S., Flynn, M., Greenlee, R. T., Kruger, R. L., Hornbrook, M. C., Roblin, D., et al. (2012) · JAMA · doi:10.1001/jama.2012.5960 · Cited by 898
Bot, M., van den Munckhof, P., Bakay, R., Stebbins, G., & Verhagen Metman, L. (2017) · Stereotactic and Functional Neurosurgery · doi:10.1159/000475672 · Cited by 671
Generalized cost-effectiveness analysis for national-level priority-setting in the health sector
Hutubessy, R., Chisholm, D., Edejer, T. T.-T., & WHO-CHOICE (2003) · Cost Effectiveness and Resource Allocation · doi:10.1186/1478-7547-1-8 · Cited by 535
Ebinger, M., Winter, B., Wendt, M., Weber, J. E., Waldschmidt, C., Rozanski, M., Kunz, A., Koch, P., Kellner, P. A., Gierhake, D., et al. (2014) · JAMA · doi:10.1001/jama.2014.2850 · Cited by 447
Low‐field MRI: An MR physics perspective
Marques, J. P., Simonis, F. F. J., & Webb, A. G. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26637 · Cited by 386
Model-Based Image Reconstruction for MRI
Fessler, J. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936726 · Cited by 335
Raich, H., & Blümler, P. (2004) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20018 · Cited by 296
Sarracanie, M., LaPierre, C. D., Salameh, N., Waddington, D. E. J., Witzel, T., & Rosen, M. S. (2015) · Scientific Reports · doi:10.1038/srep15177 · Cited by 295
Self-citationHelical CT in Emergency Radiology
Novelline, R. A., Rhea, J. T., Rao, P. M., & Stuk, J. L. (1999) · Radiology · doi:10.1148/radiology.213.2.r99nv01321 · Cited by 268
Accessible magnetic resonance imaging: A review
Geethanath, S., & Vaughan, J. T. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26638 · Cited by 244
Novel technologies and configurations of superconducting magnets for MRI
Lvovsky, Y., Stautner, E. W., & Zhang, T. (2013) · Superconductor Science and Technology · doi:10.1088/0953-2048/26/9/093001 · Cited by 237
Microtesla MRI of the human brain combined with MEG
Zotev, V. S., Matlashov, A. N., Volegov, P. L., Savukov, I. M., Espy, M. A., Mosher, J. C., Gomez, J. J., & Kraus, R. H. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.06.007 · Cited by 175
Two‐dimensional imaging in a lightweight portable MRI scanner without gradient coils
Cooley, C. Z., Stockmann, J., Armstrong, B. D., Sarracanie, M., Lev, M. H., Rosen, M. S., & Wald, L. L. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25147 · Cited by 175
Self-citationConductors for commercial MRI magnets beyond NbTi: requirements and challenges
Parizh, M., Lvovsky, Y., & Sumption, M. D. (2016) · Superconductor Science and Technology · doi:10.1088/0953-2048/30/1/014007 · Cited by 165
High-Resolution NMR Spectroscopy with a Portable Single-Sided Sensor
Perlo, J., Demas, V., Casanova, F., Meriles, C. A., Reimer, J. A., Pines, A., & Blümich, B. (2005) · Science · doi:10.1126/science.1108944 · Cited by 164
Novel approaches to low‐cost MRI
Macovski, A., & Conolly, S. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910300211 · Cited by 140
SQUID‐detected MRI at 132 μT with T1‐weighted contrast established at 10 μT–300 mT
Lee, S. K., Möβle, M., Myers, W., Kelso, N., Trabesinger, A. H., Pines, A., & Clarke, J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20316 · Cited by 139
Design of Sparse Halbach Magnet Arrays for Portable MRI Using a Genetic Algorithm
Cooley, C. Z., Haskell, M. W., Cauley, S., Sappo, C. R., LaPierre, C., Ha, C. G., Stockmann, J., & Wald, L. L. (2017) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2017.2751001 · Cited by 138
Self-citationEconomics, Helium, and the U.S. Federal Helium Reserve: Summary and Outlook
Anderson, S. T. (2017) · Natural Resources Research · doi:10.1007/s11053-017-9359-y · Cited by 132
Ex Situ NMR in Highly Homogeneous Fields: 1 H Spectroscopy
Perlo, J., Casanova, F., & Blümich, B. (2007) · Science · doi:10.1126/science.1135499 · Cited by 130
Mobile sensor for high resolution NMR spectroscopy and imaging
Danieli, E., Jörg, M., Perlo, J., Blümich, B., & Casanova, F. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.01.022 · Cited by 125
Desktop NMR and Its Applications From Materials Science To Organic Chemistry
Blümich, B., & Singh, K. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201707084 · Cited by 119
MRI with an atomic magnetometer suitable for practical imaging applications
Savukov, I., Zotev, V. S., Volegov, P. L., Espy, M. A., Matlashov, A. N., Gómez, J. J., & Kraus, R. H. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.04.012 · Cited by 110
Costing in Radiology and Health Care: Rationale, Relativity, Rudiments, and Realities
Rubin, G. D. (2017) · Radiology · doi:10.1148/radiol.2016160749 · Cited by 92
An open-access, very-low-field MRI system for posture-dependent 3He human lung imaging
Tsai, L. L., Mair, R. W., Rosen, M. S., Patz, S., & Walsworth, R. L. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.05.016 · Cited by 91
McDaniel, P. C., Cooley, C. Z., Stockmann, J., & Wald, L. L. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27861 · Cited by 84
Self-citationCost-Effectiveness Analysis in Radiology
Singer, M. E., & Applegate, K. E. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn04611 · Cited by 78
Ren, Z. H., Mu, W. C., & Huang, S. Y. (2018) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2018.2876679 · Cited by 71
The Use of a Portable Head CT Scanner in the Intensive Care Unit
Peace, K. M., Wilensky, E. M., Frangos, S. G., MacMurtrie, E., Shields, E., Hujcs, M., Levine, J. M., Kofke, A., Yang, W. P., & Roux, P. D. L. (2010) · Journal of Neuroscience Nursing · doi:10.1097/jnn.0b013e3181ce5c5b · Cited by 67
Highly Stable and Finely Tuned Magnetic Fields Generated by Permanent Magnet Assemblies
Danieli, E., Perlo, J., Blümich, B., & Casanova, F. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.180801 · Cited by 53
Medusa: A Scalable MR Console Using USB
Stang, P. P., Conolly, S., Santos, J. M., Pauly, J. M., & Scott, G. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2169681 · Cited by 49
Design of a sustainable prepolarizing magnetic resonance imaging system for infant hydrocephalus
Obungoloch, J., Harper, J. R., Consevage, S., Savukov, I., Neuberger, T., Tadigadapa, S. A., & Schiff, S. J. (2018) · Magnetic Resonance Materials in Physics Biology and Medicine · doi:10.1007/s10334-018-0683-y · Cited by 49
Blümler, P. (2016) · Concepts in Magnetic Resonance Part B · doi:10.1002/cmr.b.21320 · Cited by 39
gr-MRI: A software package for magnetic resonance imaging using software defined radios
Hasselwander, C. J., Cao, Z., & Grissom, W. A. (2016) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2016.06.023 · Cited by 37
A Fully Integrated Dual-Channel On-Coil CMOS Receiver for Array Coils in 1.5–10.5 T MRI
Sporrer, B., Wu, L., Bettini, L., Vogt, C., Reber, J., Marjanovic, J., Burger, T., Brunner, D. O., Pruessmann, K. P., Tröster, G., et al. (2017) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2017.2764443 · Cited by 31
Matter, N. I., Scott, G., Venook, R. D., Ungersma, S. E., Grafendorfer, T., Macovski, A., & Conolly, S. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21065 · Cited by 25
Neonatal imaging using an on-site small footprint MR scanner
Merhar, S. L., Tkach, J. A., Woods, J. C., South, A. P., Wiland, E. L., Rattan, M. S., Dumoulin, C. L., & Kline‐Fath, B. M. (2017) · Pediatric Radiology · doi:10.1007/s00247-017-3855-4 · Cited by 22
A home‐built digital optical MRI console using high‐speed serial links
Tang, W., Wang, W., Liu, W., Ma, Y., Tang, X., Liang, X., & Gao, J. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25403 · Cited by 14
Cited by
Low‐field MRI: Clinical promise and challenges
Arnold, T. C., Freeman, C. W., Litt, B., & Stein, J. M. (2023) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28408 · Cited by 374
A low-cost and shielding-free ultra-low-field brain MRI scanner
Liu, Y., Leong, A. T. L., Zhao, Y., Xiao, L., Mak, H. K. F., Tsang, A. C. O., Lau, G. K. K., Leung, G. K. K., & Wu, E. X. (2021) · Nature Communications · doi:10.1038/s41467-021-27317-1 · Cited by 261
Metadata
- Authors
- Wald, L. L., McDaniel, P. C., Witzel, T., Stockmann, J. P., & Cooley, C. Z.
- Venue
- Journal of Magnetic Resonance Imaging
- Publisher
- Wiley
- Published
- 2019-10-12
- Volume
- 52
- Issue
- 3
- Pages
- 686-696
- ISSN
- 1053-1807 (ISSN-L)
- 1522-2586
- OpenAlex
- W2980135163
- Cited by
- 272
- References
- 43
- FWCI
- 13.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.