CoChat

Convolutional Neural Networks for Automated Classification of Prostate Multiparametric Magnetic Resonance Imaging Based on Image Quality

Open access
Cipollari, Stefano, Guarrasi, Valerio, Pecoraro, Martina, Bicchetti, Marco, Messina, Emanuele, Farina, Lorenzo, Paci, Paola, Catalano, Carlo, Panebianco, Valeria · 2022 · Journal of Magnetic Resonance Imaging
Cited by 50

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Background: Prostate magnetic resonance imaging (MRI) is technically demanding, requiring high image quality to reach its full diagnostic potential. An automated method to identify diagnostically inadequate images could help optimize image quality. Purpose: To develop a convolutional neural networks (CNNs) based analysis pipeline for the classification of prostate MRI image quality. Study Type: Retrospective. Subjects: Three hundred sixteen prostate mpMRI scans and 312 men (median age 67). Field Strength/Sequence: A 3 T; fast spin echo T2WI, echo planar imaging DWI, ADC, gradient‐echo dynamic contrast enhanced (DCE). Assessment: MRI scans were reviewed by three genitourinary radiologists (V.P., M.D.M., S.C.) with 21, 12, and 5 years of experience, respectively. Sequences were labeled as high quality (Q1) or low quality (Q0) and used as the reference standard for all analyses. Statistical Tests: Sequences were split into training, validation, and testing sets (869, 250, and 120 sequences, respectively). Inter‐reader agreement was assessed with the Fleiss kappa. Following preprocessing and data augmentation, 28 CNNs were trained on MRI slices for each sequence. Model performance was assessed on both a per‐slice and a per‐sequence basis. A pairwise t‐test was performed to compare performances of the classifiers. Results: The number of sequences labeled as Q0 or Q1 was 38 vs. 278 for T2WI, 43 vs. 273 for DWI, 41 vs. 275 for ADC, and 38 vs. 253 for DCE. Inter‐reader agreement was almost perfect for T2WI and DCE and substantial for DWI and ADC. On the per‐slice analysis, accuracy was 89.95% ± 0.02% for T2WI, 79.83% ± 0.04% for DWI, 76.64% ± 0.04% for ADC, 96.62% ± 0.01% for DCE. On the per‐sequence analysis, accuracy was 100% ± 0.00% for T2WI, DWI, and DCE, and 92.31% ± 0.00% for ADC. The three best algorithms performed significantly better than the remaining ones on every sequence (P‐value < 0.05). Data Conclusion: CNNs achieved high accuracy in classifying prostate MRI image quality on an individual‐slice basis and almost perfect accuracy when classifying the entire sequences. Evidence Level: 4 Technical Efficacy: Stage 1

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jmri.27879

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

Metadata

Authors
Cipollari, S., Guarrasi, V., Pecoraro, M., Bicchetti, M., Messina, E., Farina, L., Paci, P., Catalano, C., & Panebianco, V.
Venue
Journal of Magnetic Resonance Imaging
Publisher
Wiley
Published
2021-08-09
Volume
55
Issue
2
Pages
480-490
ISSN
  • 1053-1807 (ISSN-L)
  • 1522-2586
OpenAlex
W3192934463
Cited by
50
References
7
FWCI
3.64
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.