The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Inductively coupled plasma mass spectrometry (ICP MS): a versatile tool
Open accessAbstract
Inductively coupled plasma (ICP) mass spectrometry (MS) is routinely used in many diverse research fields such as earth, environmental, life and forensic sciences and in food, material, chemical, semiconductor and nuclear industries. The high ion density and the high temperature in a plasma provide an ideal atomizer and element ionizer for all types of samples and matrices introduced by a variety of specialized devices. Outstanding properties such as high sensitivity (ppt–ppq), relative salt tolerance, compound‐independent element response and highest quantitation accuracy lead to the unchallenged performance of ICP MS in efficiently detecting, identifying and reliably quantifying trace elements. The increasing availability of relevant reference compounds and high separation selectivity extend the molecular identification capability of ICP MS hyphenated to species‐specific separation techniques. While molecular ion source MS is specialized in determining the structure of unknown molecules, ICP MS is an efficient and highly sensitive tool for target‐element orientated discoveries of relevant and unknown compounds. This special‐feature, tutorial article presents the principle and advantages of ICP MS, highlighting these using examples from recently published investigations. Copyright © 2007 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Atomic weights of the elements. Review 2000 (IUPAC Technical Report)
de Laeter, J. R., Böhlke, J. K., De Bièvre, P., Hidaka, H., Peiser, H. S., Rosman, K. J. R., & Taylor, P. D. P. (2003) · Pure and Applied Chemistry · doi:10.1351/pac200375060683 · Cited by 1,049
Inductively Coupled Plasma–Mass Spectrometry
(2019) · Practical Inductively Coupled Plasma Spectrometry · doi:10.1002/9781119478775.ch7 · Cited by 956
Tracing the geographical origin of food: The application of multi-element and multi-isotope analysis
Kelly, S. D., Heaton, K., & Hoogewerff, J. A. (2005) · Trends in Food Science & Technology · doi:10.1016/j.tifs.2005.08.008 · Cited by 808
Inductively coupled plasma mass spectrometry
(1998) · Spectrochemical Analysis by Atomic Absorption and Emission · doi:10.1039/9781847551894-00197 · Cited by 581
Szpunar, J. (2005) · The Analyst · doi:10.1039/b418265k · Cited by 406
(2005) · Wiley eBooks · doi:10.1002/0470856009 · Cited by 238
Inductively Coupled Plasma Mass Spectrometry
Beauchemin, D. (2010) · Analytical Chemistry · doi:10.1021/ac101187p · Cited by 221
Mass spectrometry in bioinorganic analytical chemistry
Łobiński, R., Schaumlöffel, D., & Szpunar, J. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20069 · Cited by 212
The development of multiple collector mass spectrometry for isotope ratio measurements
Wieser, M. E., & Schwieters, J. B. (2005) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2004.11.029 · Cited by 201
Handbook of Elemental Speciation: Techniques and Methodology
(2003) · Wiley eBooks · doi:10.1002/0470868384 · Cited by 197
Cornelis, R., Caruso, J., Crews, H., & Heumann, K. G. (2005) · Ghent University Academic Bibliography (Ghent University) · Cited by 175
Heumann, K. G. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2325-z · Cited by 173
Inductively Coupled Plasma Mass Spectrometry Handbook
(2005) · Wiley eBooks · doi:10.1002/9781444305463 · Cited by 170
Atomic spectrometry update. Environmental analysis
Butler, O. T., Cook, J. M., Harrington, C. F., Hill, S. J., Rieuwerts, J., & Miles, D. L. (2006) · J. Anal. At. Spectrom. · doi:10.1039/b516025c · Cited by 163
Multiple cellular antigen detection by ICP-MS
Ornatsky, O., Baranov, V. I., Bandura, D. R., Tanner, S. D., & Dick, J. E. (2005) · Journal of Immunological Methods · doi:10.1016/j.jim.2005.09.020 · Cited by 149
Rosen, A. L., & Hieftje, G. M. (2004) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2003.09.004 · Cited by 131
Gas chromatography/plasma spectrometry—an important analytical tool for elemental speciation studies
Altamirano, J. C., Wuilloud, R. G., Vonderheide, A. P., & Caruso, J. A. (2004) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/j.sab.2004.03.009 · Cited by 105
Element and molecular mass spectrometry—an emerging analytical dream team in the life sciences
Wind, M., & Lehmann, W. D. (2004) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b309482k · Cited by 98
Becker, J. S., Gorbunoff, A., Zoriy, M. V., Izmer, A. V., & Kayser, M. (2005) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b514401a · Cited by 86
Stewart, I. I., & Olesik, J. W. (1998) · Journal of Analytical Atomic Spectrometry · doi:10.1039/a804966a · Cited by 80
D’Ilio, S., Violante, N., Gregorio, M. D., Senofonte, O., & Petrucci, F. (2006) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.07.027 · Cited by 74
Protein and Proteome Phosphorylation Stoichiometry Analysis by Element Mass Spectrometry
Krüger, R., Kübler, H.-D., Pallissé, R., Burkovski, A., & Lehmann, W. D. (2006) · Analytical Chemistry · doi:10.1021/ac051896z · Cited by 74
Steady state acid effects in ICP-MS
Stewart, I. I., & Olesik, J. W. (1998) · Journal of Analytical Atomic Spectrometry · doi:10.1039/a806040a · Cited by 74
Montero, S., Wiarda, W., de Joode, P., & van der Peijl, G. (2006) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b606109e · Cited by 73
Effect of Loading Rate on the Fate of Mercury in Littoral Mesocosms
Orihel, D. M., Paterson, M. J., Gilmour, C. C., Bodaly, R. A., Blanchfield, P. J., Hintelmann, H. H., Harris, R. C., & Rudd, J. W. M. (2006) · Environmental Science & Technology · doi:10.1021/es060823+ · Cited by 72
Elemental tagging in inorganic mass spectrometric bioanalysis
Bettmer, J., Jakubowski, N., & Prange, A. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0557-4 · Cited by 69
Feldmann, I., Koehler, C. U., Roos, P. H., & Jakubowski, N. (2006) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b606773e · Cited by 64
Inductively Coupled Plasma Mass Spectrometry
Beauchemin, D. (2006) · Analytical Chemistry · doi:10.1021/ac060712t · Cited by 62
Ammann, A. A. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)01607-7 · Cited by 55
Self-citationICP-MS-assisted nanoHPLC-electrospray Q/time-of-flight MS/MS selenopeptide mapping in Brazil nuts
Dernovics, M., Giusti, P., & Łobiński, R. (2006) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b608041c · Cited by 54
Nischwitz, V., & Pergantis, S. A. (2006) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b607535e · Cited by 47
Infante, H. G., O’Connor, G., Rayman, M. P., Hearn, R., & Cook, K. (2006) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b601867j · Cited by 45
Persson, D. P., Hansen, T. H., Holm, P. E., Schjoerring, J. K., Hansen, H. C. B., Nielsen, J., Çakmak, İ., & Husted, S. (2006) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b608701a · Cited by 45
Organic Metal and Metalloid Species in the Environment
(2004) · Springer eBooks · doi:10.1007/978-3-662-09135-7 · Cited by 41
Standard Reference Materials® (SRMs) for measurement of inorganic environmental contaminants
Zeisler, R. L., Murphy, K. E., Becker, D. A., Davis, W. C., Kelly, W. R., Long, S. E., & Sieber, J. R. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0785-7 · Cited by 33
Inductively Coupled Plasma Mass Spectrometry
Beauchemin, D. (2004) · Analytical Chemistry · doi:10.1021/ac040068n · Cited by 33
Griffin, I. J. (2002) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b202249b · Cited by 29
Brüchert, W., & Bettmer, J. (2006) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b607340a · Cited by 25
Tangen, A., & Lund, W. (1999) · Spectrochimica Acta Part B Atomic Spectroscopy · doi:10.1016/s0584-8547(99)00126-3 · Cited by 25
From fluid inclusion microanalysis to large-scale hydrothermal mass transfer in the Earth's interior
Heinrich, C. A. (2006) · Journal of Mineralogical and Petrological Sciences · doi:10.2465/jmps.101.110 · Cited by 12
Analytical strategies for arsenic speciation in environmental and biological samples
Feldmann, J., Devalla, S., Raab, A., & Hansen, H. R. (2004) · Springer eBooks · doi:10.1007/978-3-662-09135-7_3 · Cited by 11
Organometal(loid) compounds associated with human metabolism
Hirner, A. V., Hartmann, L. M., Hippler, J., Kresimon, J., Koesters, J., Michalke, K., Sulkowski, M., & Rettenmeier, A. W. (2004) · Springer eBooks · doi:10.1007/978-3-662-09135-7_10 · Cited by 7
Cited by
Aspects of Spodumene Lithium Extraction Techniques
Nandihalli, N., Chouhan, R. K., Kuchi, R., & Hlova, I. Z. (2024) · Sustainability · doi:10.3390/su16198513 · Cited by 33
Mahabir, S. (2014) · PharmaNutrition · doi:10.1016/j.phanu.2013.06.002 · Cited by 15
Metadata
- Authors
- Ammann, A. A.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2007-03-27
- Volume
- 42
- Issue
- 4
- Pages
- 419-427
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W1985344993
- Cited by
- 400
- References
- 42
- FWCI
- 10.36
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.