Comparison of different mass spectrometry techniques in the measurement of L‐[ring‐13C6]phenylalanine incorporation into mixed muscle proteins
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Precise measurement of low enrichment of stable isotope labeled amino‐acid tracers in tissue samples is a prerequisite in measuring tissue protein synthesis rates. The challenge of this analysis is augmented when small sample size is a critical factor. Muscle samples from human participants following an 8 h intravenous infusion of L‐[ring‐13 C 6]phenylalanine and a bolus dose of L‐[ring‐13 C 6]phenylalanine in a mouse were utilized. Liquid chromatography tandem mass spectrometry (LC/MS/MS), gas chromatography (GC) MS/MS and GC/MS were compared to the GC‐combustion‐isotope ratio MS (GC/C/IRMS), to measure mixed muscle protein enrichment of [ring‐13 C 6]phenylalanine enrichment. The sample isotope enrichment ranged from 0.0091 to 0.1312 molar percent excess. As compared with GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS showed coefficients of determination of R 2 = 0.9962 and R 2 = 0.9942, and 0.9217 respectively. However, the precision of measurements (coefficients of variation) for intra‐assay are 13.0%, 1.7%, 6.3% and 13.5% and for inter‐assay are 9.2%, 3.2%, 10.2% and 25% for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS, respectively. The muscle sample sizes required to obtain these results were 8 µg, 0.8 µg, 3 µg and 3 µg for GC/C/IRMS, LC/MS/MS, GC/MS/MS and GC/MS, respectively. We conclude that LC/MS/MS is optimally suited for precise measurements of L‐[ring‐13 C 6]phenylalanine tracer enrichment in low abundance and in small quantity samples. Copyright © 2013 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Age and aerobic exercise training effects on whole body and muscle protein metabolism
Short, K. R., Vittone, J. L., Bigelow, M. L., Proctor, D. N., & Nair, K. S. (2004) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00366.2003 · Cited by 470
Self-citationBrodsky, I. G., Balagopal, P., & Nair, K. S. (1996) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.81.10.8855787 · Cited by 444
Self-citationChow, L. S., Albright, R. C., Bigelow, M. L., Toffolo, G., Cobelli, C., & Nair, K. S. (2006) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00003.2006 · Cited by 127
Self-citationJaleel, A., Klaus, K. A., Morse, D. M., Karakelides, H., Ward, L. E., Irving, B. A., & Nair, K. S. (2009) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00351.2009 · Cited by 23
Self-citation
Cited by
Monteyne, A. J., Coelho, M. O., Porter, C., Abdelrahman, D. R., Jameson, T. S., Jackman, S. R., Blackwell, J. R., Finnigan, T. J., Stephens, F. B., Dirks, M. L., et al. (2020) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/nqaa092 · Cited by 110
Robinson, M. M., Soop, M., Sohn, T. S., Morse, D. M., Schimke, J. M., Klaus, K. A., & Nair, K. S. (2014) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2014-2736 · Cited by 59
Self-citationZabielski, P., Lanza, I. R., Gopala, S., Holtz Heppelmann, C. J., Bergen, H. R., Dasari, S., & Nair, K. S. (2016) · Diabetes · doi:10.2337/db15-0823 · Cited by 54
“Mixed Muscle Protein Synthesis Rates The fractional synthesis rates of mixed muscle proteins were measured in mice quadriceps skeletal muscle using L-[ring-(13)C6]phenylalanine (Cambridge Isotope Laboratories, Tewksbury, MA) and MS, as described earlier (22,24,25).”
MethodSelf-citationMonteyne, A. J., Coelho, M. O., Porter, C., Abdelrahman, D. R., Jameson, T. S., Finnigan, T. J., Stephens, F. B., Dirks, M. L., & Wall, B. T. (2020) · The Journal of Nutrition · doi:10.1093/jn/nxaa251 · Cited by 29
Robinson, M. M., Dasari, S., Karakelides, H., Bergen, H. R., & Nair, K. S. (2016) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00175.2016 · Cited by 22
Self-citation
Metadata
- Authors
- Zabielski, P., Ford, G. C., Persson, X. M., Jaleel, A., Dewey, J. D., & Nair, K. S.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2013-02
- Volume
- 48
- Issue
- 2
- Pages
- 269-275
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W1583851767
- Cited by
- 32
- References
- 4
- FWCI
- 1.89
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of different mass spectrometry techniques in the measurement of L‐[ring‐13C6]phenylalanine incorporation into mixed muscle proteins. https://app.cochat.ai/papers/10.1002/jms.3120
- The paper
- Zabielski, P., Ford, G. C., Persson, X. M., Jaleel, A., Dewey, J. D., & Nair, K. S. (2013). Comparison of different mass spectrometry techniques in the measurement of L‐[ring‐13C6]phenylalanine incorporation into mixed muscle proteins. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.3120
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.