Multi‐turn time‐of‐flight mass spectrometers with electrostatic sectors
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The mass resolution of a time‐of‐flight (TOF) mass spectrometer is directly proportional to its total flight pathlength. Multi‐turn or multi‐passage ion optical geometries are necessary to obtain fight distances of sufficient length within reasonable size limitations. We have investigated ion optics for a multi‐turn TOF mass spectrometer with electrostatic sectors. The concept of ‘perfect’ focusing conditions is introduced. Furthermore, a new type of multi‐turn TOF mass spectrometer, the MULTUM Linear plus, was developed. It consists of four cylindrical electric sectors and 28 electric quadrupole lenses. It has a vacuum chamber 60 × 70 × 20 cm in size. Mass resolution is demonstrated to increase according to the number of ion cycles. A mass resolution of 350 000 (m/z = 28, FWHM) was achieved after 501.5 cycles. The MULTUM Linear plus analyzer is not simple, however; 28 electric quadrupole lenses are used. In order to reduce the number of ion optical parts, an improved multi‐turn TOF mass spectrometer, the MULTUM II, consisting of only four toroidal electric sectors, was also developed. The possibility of tandem mass spectrometric applications using multi‐turn TOF mass spectrometers is also discussed. Copyright © 2003 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930
Covey, T. R., Huang, E. C., & Henion, J. D. (1991) · Analytical Chemistry · doi:10.1021/ac00013a003 · Cited by 446
Cited by
Ion Mobility-Mass Spectrometry: Time-Dispersive Instrumentation
May, J. C., & McLean, J. A. (2015) · Analytical Chemistry · doi:10.1021/ac504720m · Cited by 435
High-Resolution Mass Spectrometers
Marshall, A. G., & Hendrickson, C. L. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112945 · Cited by 394
High Resolution Mass Spectrometry
Xian, F., Hendrickson, C. L., & Marshall, A. G. (2012) · Analytical Chemistry · doi:10.1021/ac203191t · Cited by 281
Measurement of Individual Ions Sharply Increases the Resolution of Orbitrap Mass Spectra of Proteins
Kafader, J. O., Melani, R. D., Senko, M. W., Makarov, A. A., Kelleher, N. L., & Compton, P. D. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.8b04519 · Cited by 87
Körber, A., Anthony, I. G. M., & Heeren, R. M. A. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c05249 · Cited by 88
The sTOF, a Favorable Geometry for a Time-of-Flight Analyzer
Murphy, D. M. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1518-6 · Cited by 9
Metadata
- Authors
- Toyoda, M., Okumura, D., Ishihara, M., & Katakuse, I.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2003-11
- Volume
- 38
- Issue
- 11
- Pages
- 1125-1142
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W2103157466
- Cited by
- 106
- References
- 2
- FWCI
- 1.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.