Triple quadrupole linear ion trap mass spectrometer for the analysis of small molecules and macromolecules
Open accessAbstract
Recently, linear ion traps (LITs) have been combined with quadrupole (Q), time‐of‐flight (TOF) and Fourier transform ion cyclotron resonance (FT‐ICR) mass spectrometery (MS). LITs can be used either as ion accumulation devices or as commercially available, stand‐alone mass spectrometers with MSn capabilities. The combination of triple quadrupole MS with LIT technology in the form of an instrument of configuration QqLIT, using axial ejection, is particularly interesting, because this instrument retains the classical triple quadrupole scan functions such as selected reaction monitoring (SRM), product ion (PI), neutral loss (NL) and precursor ion (PC) while also providing access to sensitive ion trap experiments. For small molecules, quantitative and qualitative analysis can be performed using the same instrument. In addition, for peptide analysis, the enhanced multiply charged (EMC) scan allows an increase in selectivity, while the time‐delayed fragmentation (TDF) scan provides additional structural information. Various methods of operating the hybrid instrument are described for the case of the commercial Q TRAP (AB/MDS Sciex) and applications to drug metabolism analysis, quantitative confirmatory analysis, peptides analysis and automated nanoelectrospray (ESI‐chip‐MS) analysis are discussed. Copyright © 2004 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Electromagnetic traps for charged and neutral particles
Paul, W. (1990) · Reviews of Modern Physics · doi:10.1103/revmodphys.62.531 · Cited by 1,561
(1995) · Springer eBooks · doi:10.1007/978-94-011-0161-5 · Cited by 1,250
A two-dimensional quadrupole ion trap mass spectrometer
Schwartz, J. C., Senko, M. W., & Syka, J. E. P. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00384-7 · Cited by 796
Proceedings of the 46th ASMS Conference on Mass Spectrometry and Allied Topics
Bruins, A. P. (1998) · Cited by 642
A new linear ion trap mass spectrometer
Hager, J. W. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.607 · Cited by 479
Liquid chromatography/atmospheric pressure ionization–mass spectrometry in drug metabolism studies
Kostiainen, R., Kotiaho, T., Kuuranne, T., & Auriola, S. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.481 · Cited by 349
Syka, J. E. P., Marto, J. A., Bai, D. L., Horning, S., Senko, M. W., Schwartz, J. C., Ueberheide, B., Garcia, B., Busby, S., Muratore, T., et al. (2004) · Journal of Proteome Research · doi:10.1021/pr0499794 · Cited by 348
A Fully Integrated Monolithic Microchip Electrospray Device for Mass Spectrometry
Schultz, G. A., Corso, T. N., Prosser, S. J., & Zhang, S. (2000) · Analytical Chemistry · doi:10.1021/ac000325y · Cited by 284
Quantitative high‐throughput analysis of drugs in biological matrices by mass spectrometry
Hopfgartner, G., & Bourgogne, E. (2003) · Mass Spectrometry Reviews · doi:10.1002/mas.10050 · Cited by 266
Self-citationA Micromachined Chip-Based Electrospray Source for Mass Spectrometry
Licklider, L., Wang, X.-Q., Desai, A., Tai, Y.-C., & Lee, T. D. (2000) · Analytical Chemistry · doi:10.1021/ac990967p · Cited by 194
Peer Reviewed: Systematic LC/MS Metabolite Identification in Drug Discovery
Clarke, N. J., Rindgen, D., Korfmacher, W. A., & Cox, K. (2001) · Analytical Chemistry · doi:10.1021/ac012480y · Cited by 155
Blanc, J. C. Y. L., Hager, J. W., Ilisiu, A. M. P., Hunter, C. L., Zhong, F., & Chu, I. K. (2003) · PROTEOMICS · doi:10.1002/pmic.200300415 · Cited by 147
Anari, M. R., Sánchez, R. I., Bakhtiar, R., Franklin, R. B., & Baillie, T. A. (2003) · Analytical Chemistry · doi:10.1021/ac034980s · Cited by 137
Hopfgartner, G., Husser, C., & Zell, M. (2003) · Journal of Mass Spectrometry · doi:10.1002/jms.420 · Cited by 129
Self-citationLiquid chromatography–mass spectrometry: potential in forensic and clinical toxicology
Marquet, P. P., & Lachâtre, G. (1999) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00147-4 · Cited by 124
A combined linear ion trap time‐of‐flight system with improved performance and MS n capabilities
Collings, B. A., Campbell, J. M., Mao, D., et al. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.440 · Cited by 98
Recent trends in mass spectrometer development
Hager, J. W. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2287-1 · Cited by 68
Metabolite Identification in Drug Discovery
Swarbrick, J. (2006) · CRC Press eBooks · doi:10.1201/b21612-18 · Cited by 63
Matuszewski, B. K., Chavez-Eng, C. M., & Constanzer, M. L. (1998) · Journal of Chromatography B Biomedical Sciences and Applications · doi:10.1016/s0378-4347(98)00317-x · Cited by 52
Hoke, S. H., Morand, K. L., Greis, K. D., Baker, T. R., Harbol, K. L., & Dobson, R. L. M. (2001) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(01)00499-7 · Cited by 46
Belov, M. E., Николаев, Е. Н., Alving, K., et al. (2001) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.356 · Cited by 29
Cited by
Mass spectrometry–based proteomics turns quantitative
Ong, S.-E., & Mann, M. (2005) · Nature Chemical Biology · doi:10.1038/nchembio736 · Cited by 1,572
Farré, M. L., Pérez, S., Kantiani, L., & Barceló, D. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.09.010 · Cited by 1,009
Zubarev, R. A., & Makarov, A. (2013) · Analytical Chemistry · doi:10.1021/ac4001223 · Cited by 658
Rauniyar, N. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms161226120 · Cited by 406
“Targeted experiments are primarily performed on a triple-quadrupole (QQQ) and hybrid quadrupole-linear ion trap (QTrap) mass spectrometers using a data acquisition method known as Selected Reaction Monitoring (SRM) [1,2].”
MethodMetabolomics for clinical use and research in chronic kidney disease
Hocher, B., & Adamski, J. (2017) · Nature Reviews Nephrology · doi:10.1038/nrneph.2017.30 · Cited by 339
Metadata
- Authors
- Hopfgartner, G., Varesio, E., Tschäppät, V., Grivet, C., Bourgogne, E., & Leuthold, L. A.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2004-08
- Volume
- 39
- Issue
- 8
- Pages
- 845-855
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W2109474157
- Cited by
- 287
- References
- 24
- FWCI
- 6.38
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.