The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Subcellular imaging mass spectrometry of brain tissue
Abstract
Imaging mass spectrometry provides both chemical information and the spatial distribution of each analyte detected. Here it is demonstrated how imaging mass spectrometry of tissue at subcellular resolution can be achieved by combining the high spatial resolution of secondary ion mass spectrometry (SIMS) with the sample preparation protocols of matrix‐assisted laser desorption/ionization (MALDI). Despite mechanistic differences and sampling 10 5 times less material, matrix‐enhanced (ME)‐SIMS of tissue samples yields similar results to MALDI (up to m/z 2500), in agreement with previous studies on standard compounds. In this regard ME‐SIMS represents an attractive alternative to polyatomic primary ions for increasing the molecular ion yield. ME‐SIMS of whole organs and thin sections of the cerebral ganglia of Lymnaea stagnalis demonstrate the advantages of ME‐SIMS for chemical imaging mass spectrometry. Subcellular distributions of cellular analytes are clearly obtained, and the matrix provides an in situ height map of the tissue, allowing the user to identify rapidly regions prone to topographical artifacts and to deconvolute topographical losses in mass resolution and signal‐to‐noise ratio. Copyright © 2005 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Cited by
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Self-citationBioimaging of metals by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS)
Becker, J. S., Zoriy, M., Matusch, A., Wu, B., Salber, D., Palm, C., & Becker, J. S. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20239 · Cited by 287
Metadata
- Authors
- McDonnell, L. A., Piersma, S. R., Altelaar, A. F. M., Mize, T. H., Luxembourg, S. L., Verhaert, P. D. E. M., van Minnen, J., & Heeren, R. M. A.
- Venue
- Journal of Mass Spectrometry
- Publisher
- Wiley
- Published
- 2005-02
- Volume
- 40
- Issue
- 2
- Pages
- 160-168
- ISSN
- 1076-5174 (ISSN-L)
- 1096-9888
- OpenAlex
- W2013663489
- Cited by
- 173
- References
- 1
- FWCI
- 9.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subcellular imaging mass spectrometry of brain tissue. https://app.cochat.ai/papers/10.1002/jms.735
- The paper
- McDonnell, L. A., Piersma, S. R., Altelaar, A. F. M., Mize, T. H., Luxembourg, S. L., Verhaert, P. D. E. M., van Minnen, J., & Heeren, R. M. A. (2005). Subcellular imaging mass spectrometry of brain tissue. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.735
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.