CoChat

Validated toxicological determination of 30 drugs of abuse as optimized derivatives in oral fluid by long column fast gas chromatography/electron impact mass spectrometry

Gunnar, Teemu, Ariniemi, Kari, Lillsunde, Pirjo · 2005 · Journal of Mass Spectrometry
Cited by 118

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

An analytical procedure was developed for the simultaneous sensitive identification, screening and quantitation of 30 drugs of abuse using 250 µl of human oral fluid. The method employs sequential mixed‐mode solid‐phase extraction (SPE), optimized derivative formation and long‐column fast gas chromatography/electron impact mass spectrometry (GC/EI‐MS). After sequential SPE elution, the most sensitive and stable derivatives were formed by taking careful account of the characteristics of the active functional groups and possible steric hindrances affecting derivatization chemistry. Amphetamine‐type stimulant drugs were acylated with heptafluorobutyric anhydride, benzodiazepines and Δ 9‐tetrahydrocannabinol were silylated with N‐methyl‐N‐(tert‐butyldimethylsilyl)trifluoroacetamide and benzoylecgonine, codeine, ethylmorphine, 6‐monoacetylmorphine, morphine, pholcodine, buprenorphine and norbuprenorphine with N‐methyl‐N‐(trimethylsilyl)trifluoroacetamide. In addition, the following analytes were included: methadone, cocaine, alprazolam, midazolam, fentanyl and zolpidem. In GC separation, fast temperature ramping and high carrier gas flow‐rate combined with long 30 m columns of i.d. 0.32 mm offered a reduction in analysis time and sharp peak shapes while still maintaining sufficient resolution and high sample capacity. Validated parameters including selectivity, linearity, accuracy, intra‐ and inter‐day precision, extraction efficiency and limit of quantitation were all within required limits. In contrast to previously published methods, this single procedure is suitable for the simultaneous toxicological determination of the most common illicit drugs and benzodiazepines, and also zolpidem, in a small amount of oral fluid. Copyright © 2005 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jms.846

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 118

Metadata

Authors
Gunnar, T., Ariniemi, K., & Lillsunde, P.
Venue
Journal of Mass Spectrometry
Publisher
Wiley
Published
2005-04
Volume
40
Issue
6
Pages
739-753
ISSN
  • 1076-5174 (ISSN-L)
  • 1096-9888
OpenAlex
W2150928922
Cited by
118
References
1
FWCI
16.94
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validated toxicological determination of 30 drugs of abuse as optimized derivatives in oral fluid by long column fast gas chromatography/electron impact mass spectrometry. https://app.cochat.ai/papers/10.1002/jms.846
The paper
Gunnar, T., Ariniemi, K., & Lillsunde, P. (2005). Validated toxicological determination of 30 drugs of abuse as optimized derivatives in oral fluid by long column fast gas chromatography/electron impact mass spectrometry. Journal of Mass Spectrometry. https://doi.org/10.1002/jms.846

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.