The DOI matches its Crossref record.
The evaluation of a biphasic calcium phosphate ceramic for use in grafting long‐bone diaphyseal defects
Abstract
The effectiveness of a sintered hydroxyapatite‐tricalcium phosphate (HA‐TCP) ceramic in bridging large diaphyseal defects in the canine ulna was studied. One‐hundred percent morselized HA‐TCP, a 50:50 mixture of morselized HA‐TCP, and autogenous cancellous bone, and 100% autogenous cancellous bone were used to bridge 2.5‐cm defects in the left ulnae of three groups of six dogs each. At 24 weeks the ulnae were explanted and studied by radiography, microradiography, mechanical testing, and histology. Pure HA/TCP was not osteoinductive, and four of six ulnae in this group progressed to a fibrous nonunion. The HA/TCP‐cancellous bone mixture and pure cancellous bone were approximately equal in effect, leading to good callus formation at 4 weeks and strong bony union by 24 weeks, with no evidence of bioincompatibility. Morselized HA/TCP promises to be useful as a graft extender when mixed with autogenous cancellous bone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Tissue-engineered bone regeneration
Petite, H., Viateau, V., Bensaïd, W., Meunier, A., de Pollak, C., Bourguignon, M., Oudina, K., Sedel, L., & Guillemin, G. (2000) · Nature Biotechnology · doi:10.1038/79449 · Cited by 1,475
Bone graft and bone graft substitutes: A review of current technology and applications
Damien, C. J., & Parsons, J. R. (1991) · Journal of Applied Biomaterials · doi:10.1002/jab.770020307 · Cited by 1,058
Alternatives to Autogenous Bone Graft: Efficacy and Indications
Gazdag, A. R., Lane, J. M., Glaser, D., & Forster, R. A. (1995) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/00124635-199501000-00001 · Cited by 612
Review of bone graft and bone substitutes with an emphasis on fracture surgeries
Sohn, H.-S., & Oh, J.-K. (2019) · Biomaterials Research · doi:10.1186/s40824-019-0157-y · Cited by 526
Mesenchymal Stem Cells in Osteobiology and Applied Bone Regeneration
Bruder, S. P., Jaiswal, N., Ricalton, N. S., Mosca, J. D., Kraus, K. H., & Kadiyala, S. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00025 · Cited by 436
Metadata
- Authors
- Moore, D. C., Chapman, M. W., & Manske, D.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1987-01
- Volume
- 5
- Issue
- 3
- Pages
- 356-365
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2144395489
- Cited by
- 164
- References
- 0
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The evaluation of a biphasic calcium phosphate ceramic for use in grafting long‐bone diaphyseal defects. https://app.cochat.ai/papers/10.1002/jor.1100050307
- The paper
- Moore, D. C., Chapman, M. W., & Manske, D. (1987). The evaluation of a biphasic calcium phosphate ceramic for use in grafting long‐bone diaphyseal defects. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100050307
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.