The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Estimation of mechanical properties of cortical bone by computed tomography
Abstract
It is difficult to assess from conventional x‐rays the amount of loading that a bone can tolerate. The question therefore was asked whether the mechanical properties of cortical bone could be estimated by using a computed tomography (CT) system typically employed in the clinical setting. In vitro cross sectional diaphyseal scans of adult human tibiae were made using a GE 9800 scanner and linear attenuation coefficients determined in several regions of the central cross sections. Samples from the mid‐diaphyses of these tibiae were harvested, tested in three‐point bending to failure, and mechanical properties as well as density and ash fraction determined. The respective relationships between CT measurements, mechanical properties and physical properties were calculated using regression analysis. In addition a solid calibration phantom (tricalciumphosphate) was scanned to evaluate the variability of CT measurements. The physical parameters measured in this study were found to be comparable with data from other authors but correlations coefficients with CT data: r = 0.55 (Young's modulus), r = 0.50 (strength), r = 0.65 (apparent density) and r = 0.46 (ash fraction). The correlation coefficients of these regressions for both linear and power fits were not significantly different. A high linear correlation (r = 0.99) was found between the chamber densities and the measured attenuation coefficients, but accuracy varied between 2 and 6%. The small range of specimen mechanical properties as well as the limitations inherent with the methods employed may explain these results. We conclude that clinical equipment as used in this study is not sufficient to accurately estimate the mechanical properties of cortical bone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
The Mechanical Properties of Cortical Bone
REILLY, D. T., & BURSTEIN, A. H. (1974) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197456050-00012 · Cited by 653
Stiffness of compact bone: Effects of porosity and density
Schaffler, M. B., & Burr, D. B. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90186-8 · Cited by 652
The mechanical properties of bone tissue in children
Currey, J., & Butler, G. (1975) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197557060-00015 · Cited by 453
Prediction of vertebral body compressive fracture using quantitative computed tomography.
McBroom, R. J., Hayes, W. C., Edwards, W. T., Goldberg, R. P., & White, A. A. (1985) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198567080-00010 · Cited by 432
Mechanical Properties and Composition of Cortical Bone
CARTER, D. R., & SPENGLER, D. M. (1978) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197809000-00041 · Cited by 407
Quantitative Bone Mineral Analysis Using Dual Energy Computed Tomography
GENANT, H. K., & BOYD, D. (1977) · Investigative Radiology · doi:10.1097/00004424-197711000-00015 · Cited by 397
Current concepts of internal fixation of fractures
Tubbs, N. (1981) · Injury · doi:10.1016/0020-1383(81)90078-4 · Cited by 326
Ruegsegger, P., Dambacher, M. A., Ruegsegger, E., Fischer, J. A., & Anliker, M. (1984) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-198466070-00007 · Cited by 111
Esses, S. I., Lotz, J. C., & Hayes, W. C. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040510 · Cited by 94
A review of the biomechanical properties of bone as a material
NATALI, A. N., & Meroi, E. A. (1989) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(89)90058-7 · Cited by 93
Mechanical strength of tibial trabecular bone evaluated by X-ray computed tomography
Bentzen, S. M., Hvid, I., & Jorgensen, J. (1987) · Journal of Biomechanics · doi:10.1016/0021-9290(87)90053-4 · Cited by 76
Structural Properties of Immature Canine Bone
Torzilli, P. A., Takebe, K., Burstein, A. H., & Heiple, K. G. (1981) · Journal of Biomechanical Engineering · doi:10.1115/1.3138286 · Cited by 71
Structural consequences of endosteal metastatic lesions in long bones
Hipp, J. A., McBroom, R., Cheal, E. J., & Hayes, W. C. (1989) · Journal of Orthopaedic Research® · doi:10.1002/jor.1100070609 · Cited by 49
Cited by
Relations of mechanical properties to density and CT numbers in human bone
Rho, J. Y., Hobatho, M. C., & Ashman, R. B. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)97314-f · Cited by 822
Predicting the compressive mechanical behavior of bone
Keller, T. S. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90056-6 · Cited by 667
Mathematical relationships between bone density and mechanical properties: A literature review
Helgason, B., Perilli, E., Schileo, E., Taddei, F., Brynjólfsson, S., & Viceconti, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.024 · Cited by 589
Schileo, E., Dall’Ara, E., Taddei, F., Malandrino, A., Schotkamp, T., Baleani, M., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.05.017 · Cited by 372
Subject-Specific Finite Element Model of the Pelvis: Development, Validation and Sensitivity Studies
Anderson, A. E., Peters, C. L., Tuttle, B. D., & Weiss, J. A. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.1894148 · Cited by 347
Metadata
- Authors
- Snyder, S. M., & Schneider, E.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1991-05
- Volume
- 9
- Issue
- 3
- Pages
- 422-431
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1997159890
- Cited by
- 291
- References
- 14
- FWCI
- 3.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.