The DOI matches its Crossref record.
Telemeterized in vivo hip joint force data: A report on two patients after total hip surgery
Abstract
Two telemeterized femoral components were implanted in two patients as part of normal total hip replacement procedures. The two components were instrumented to measure the three force components directed along: (a) the neck axis, (b) transverse to the neck axis and in the plane of the prosthesis, and (c) transverse to the neck axis and perpendicular to the plane of the prosthesis. Data were collected at multiple sessions during the early postoperative period for a number of standard activities, including gait, stair climbing, rising from a chair, single leg stance, double leg stance, ipsilateral and contralateral straight leg lifts while supine, ipsilateral flexion and extension while standing, and ipsilateral abduction while standing and lying on the contralateral side. These data are summarized and compared with the published results from analytic studies and with the results from previous studies using instrumented femoral components. Peak loads for gait during the period of study were roughly 2.7 body weights (BW) when the patients walked at their normal pace. Contact forces at the hip during stationary single leg stance approximated the peak loads during gait with values ranging from 2.1 to 2.8 BW. The highest forces recorded reached values approaching 5.5 BW and occurred during periods of instability while the patient engaged in stationary single leg stance. Our in vivo data indicate that forces generated during the above activities increase in magnitude quite rapidly during the early postoperative period and that during this period the patients have the ability to perform the activities of daily living without generating the high amplitude joint contact forces suggested by the results of dynamic studies. Joint contact forces during gait were found to depend on speed, but the high absolute magnitudes predicted by model studies were not supported by the in vivo data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Properties of acrylic bone cement: State of the art review
Lewis, G. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199722)38:2<155::aid-jbm10>3.0.co;2-c · Cited by 744
Borer, K. T. (2005) · Sports Medicine · doi:10.2165/00007256-200535090-00004 · Cited by 373
Duration and frequency of every day activities in total hip patients
Morlock, M., Schneider, E., Bluhm, A., Vollmer, M., Bergmann, G., Müller, V, & Honl, M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00035-5 · Cited by 360
Torzilli, P. A., Grigiene, R., Borrelli, J., & Helfet, D. L. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2835070 · Cited by 326
Kohrt, W. M., Ehsani, A. A., & Birge, S. J. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.8.1253 · Cited by 271
Metadata
- Authors
- Kotzar, G. M., Davy, D. T., Goldberg, V. M., Heiple, K. G., Berilla, J., Heiple, K. G., Brown, R. H., & Burstein, A. H.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1991-09
- Volume
- 9
- Issue
- 5
- Pages
- 621-633
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1978427781
- Cited by
- 190
- References
- 0
- FWCI
- 1.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Telemeterized in vivo hip joint force data: A report on two patients after total hip surgery. https://app.cochat.ai/papers/10.1002/jor.1100090502
- The paper
- Kotzar, G. M., Davy, D. T., Goldberg, V. M., Heiple, K. G., Berilla, J., Heiple, K. G., Brown, R. H., & Burstein, A. H. (1991). Telemeterized in vivo hip joint force data: A report on two patients after total hip surgery. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100090502
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.