Telemeterized in vivo hip joint force data: A report on two patients after total hip surgery
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Two telemeterized femoral components were implanted in two patients as part of normal total hip replacement procedures. The two components were instrumented to measure the three force components directed along: (a) the neck axis, (b) transverse to the neck axis and in the plane of the prosthesis, and (c) transverse to the neck axis and perpendicular to the plane of the prosthesis. Data were collected at multiple sessions during the early postoperative period for a number of standard activities, including gait, stair climbing, rising from a chair, single leg stance, double leg stance, ipsilateral and contralateral straight leg lifts while supine, ipsilateral flexion and extension while standing, and ipsilateral abduction while standing and lying on the contralateral side. These data are summarized and compared with the published results from analytic studies and with the results from previous studies using instrumented femoral components. Peak loads for gait during the period of study were roughly 2.7 body weights (BW) when the patients walked at their normal pace. Contact forces at the hip during stationary single leg stance approximated the peak loads during gait with values ranging from 2.1 to 2.8 BW. The highest forces recorded reached values approaching 5.5 BW and occurred during periods of instability while the patient engaged in stationary single leg stance. Our in vivo data indicate that forces generated during the above activities increase in magnitude quite rapidly during the early postoperative period and that during this period the patients have the ability to perform the activities of daily living without generating the high amplitude joint contact forces suggested by the results of dynamic studies. Joint contact forces during gait were found to depend on speed, but the high absolute magnitudes predicted by model studies were not supported by the in vivo data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Contact pressures in the human hip joint measured in vivo.
Hodge, W. A., Fijan, R. S., Carlson, K. L., Burgess, R. G., Harris, W. H., & Mann, R. W. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.9.2879 · Cited by 623
A biomechanical investigation of the human hip
Crowninshield, R. D., Johnston, R. C., Andrews, J. G., & Brand, R. A. (1978) · Journal of Biomechanics · doi:10.1016/0021-9290(78)90045-3 · Cited by 448
Hardt, D. E. (1978) · Journal of Biomechanical Engineering · doi:10.1115/1.3426195 · Cited by 432
Telemetric force measurements across the hip after total arthroplasty.
Davy, D. T., Kotzar, G. M., Brown, R. H., Heiple, K. G., Goldberg, V. M., Heiple, K. G., Berilla, J., & Burstein, A. H. (1988) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198870010-00008 · Cited by 416
Self-citationFoeces transmitted by joints in the human body
Poul, J. (1967) · Cited by 334
Use of Optimization Techniques to Predict Muscle Forces
Crowninshield, R. D. (1978) · Journal of Biomechanical Engineering · doi:10.1115/1.3426197 · Cited by 328
Abduction forces in the one-legged stance
McLeish, R. D., & Charnley, J. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90006-0 · Cited by 262
Approaches to design - Force actions transmitted by joints in the human body
Paul, J. P. (1976) · Proceedings of the Royal Society B Biological Sciences · doi:10.1098/rspb.1976.0004 · Cited by 257
Joint forces in the human pelvis-leg skeleton during walking
Röhrle, H., Scholten, R., Sigolotto, C., Sollbach, W., & Kellner, H. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90033-2 · Cited by 185
In vivo records of hip loads using a femoral implant with telemetric output (a prelimary report)
English, T. A., & Kilvington, M. (1979) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(79)90066-9 · Cited by 159
Cited by
Properties of acrylic bone cement: State of the art review
Lewis, G. (1997) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199722)38:2<155::aid-jbm10>3.0.co;2-c · Cited by 744
Borer, K. T. (2005) · Sports Medicine · doi:10.2165/00007256-200535090-00004 · Cited by 373
Duration and frequency of every day activities in total hip patients
Morlock, M., Schneider, E., Bluhm, A., Vollmer, M., Bergmann, G., Müller, V, & Honl, M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00035-5 · Cited by 360
Torzilli, P. A., Grigiene, R., Borrelli, J., & Helfet, D. L. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2835070 · Cited by 326
Kohrt, W. M., Ehsani, A. A., & Birge, S. J. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.8.1253 · Cited by 271
Whole Bone Mechanics and Bone Quality
Cole, J. H., & van der Meulen, M. C. H. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-011-1784-3 · Cited by 169
“The lowest forces occurred during nonweightbearing rehabilitation exercises and the highest forces while rising from a chair or climbing stairs [7, 74].”
A fabric-dependent fracture criterion for bone
Pietruszczak, S., Inglis, D., & Pande, G. N. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00096-2 · Cited by 51
Metadata
- Authors
- Kotzar, G. M., Davy, D. T., Goldberg, V. M., Heiple, K. G., Berilla, J., Heiple, K. G., Brown, R. H., & Burstein, A. H.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1991-09
- Volume
- 9
- Issue
- 5
- Pages
- 621-633
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1978427781
- Cited by
- 190
- References
- 12
- FWCI
- 1.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.