The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effects of material properties of femoral hip components on bone remodeling
Open accessAbstract
Bone loss around femoral hip stems is one of the problems threatening the long‐term fixation of uncemented stems. Many believe that this phenomenon is caused by reduced stresses in the bone (stress shielding). In the present study the mechanical consequences of different femoral stem materials were investigated using adaptive bone remodeling theory in combination with the finite element method. Bone‐remodeling in the femur around the implant and interface stresses between bone and implant were investigated for fully bonded femoral stems. Cemented stems (cobalt‐chrome or titanium alloy) caused less bone resorption and lower interface stresses than uncemented stems made from the same materials. The range of the bone resorption predicted in the simulation models was from 23% in the proximal medial cortex surrounding the cemented titanium alloy stem to 76% in the proximal medial cortex around the uncemented cobalt‐chrome stem. Very little bone resorption was predicted around a flexible, uncemented “iso‐elastic” stem, but the proximal interface stresses increased drastically relative to the stiffer uncemented stems composed of cobalt‐chrome or titanium alloy. However, the proximal interface stress peak was reduced and shifted during the adaptive remodeling process. The latter was found particularly in the stiffer uncemented cobalt‐chrome‐molybdenum implant and less for the flexible isoelastic implant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Cited by
Stress shielding and fatigue limits of poly‐ether‐ether‐ketone dental implants
Lee, W., Koak, J., Lim, Y., Kim, S., Kwon, H., & Kim, M. (2012) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.32669 · Cited by 268
Finite element models in tissue mechanics and orthopaedic implant design
Prendergast, P. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00018-1 · Cited by 255
Surface morphology optimization for osseointegration of coated implants
Rungsiyakull, C., Li, Q., Sun, G., Li, W., & Swain, M. V. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.05.077 · Cited by 105
Metadata
- Authors
- Weinans, H., Huiskes, R., & Grootenboer, H. J.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1992-11
- Volume
- 10
- Issue
- 6
- Pages
- 845-853
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2101105617
- Cited by
- 194
- References
- 1
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effects of material properties of femoral hip components on bone remodeling. https://app.cochat.ai/papers/10.1002/jor.1100100614
- The paper
- Weinans, H., Huiskes, R., & Grootenboer, H. J. (1992). Effects of material properties of femoral hip components on bone remodeling. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100100614
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.