The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Influence of size and stability of the osteotomy gap on the success of fracture healing
Abstract
Flexible fixation of fractures with minimally invasive surgical techniques has become increasingly popular. Such techniques can lead to relatively large fracture gaps (larger than 5 mm) and considerable interfragmentary movements (0.2‐5 mm). We investigated the influence of the size of the fracture gap, interfragmentary movement, and interfragmentary strain on the quality of fracture healing. A simple diaphyseal long‐bone fracture was modeled by means of a transverse osteotomy of the right metatarsus in sheep. In 42 Sheep, the metatarsus was stabilized with a custom‐made external ring fixator that was adjustable for gap size and axial interfragmentary movement. The sheep were randomly divided into six groups with three different gap sizes (1, 2, or 6 mm) and small or large interfragmentary strain (approximately 7 or 31%). The movement of the fracture gap was monitored telemetrically by a displacement transducer attached to the fixator. After 9 weeks of healing, the explanted metatarsus was evaluated mechanically in a three‐point bending test to determine bending, stiffness and was radiographed to measure the amount of periosteal callus formation. Increased size of the gap (from 1 to 6 mm) resulted in a significant reduction in the bending stiffness of the healed bones. Larger interfragmentary movements and strains (31 compared with 7%) stimulated larger callus formation for small gaps (1‐2 mm) but not for larger gaps (approximately 6 mm). The treatment of simple diaphyseal fractures with flexible fixation can be improved by careful reduction of the fracture; this prevents large interfragmentary gaps. The experimental fracture model for the metatarsus showed that the healing process was inferior when the gap was larger than 2 mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The biology of fracture healing in long bones
McKibbin, B. (1978) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.60b2.350882 · Cited by 1,180
Controlled mechanical stimulation in the treatment of tibial fractures
KENWRIGHT, J., & GOODSHIP, A. E. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198904000-00006 · Cited by 373
Current concepts of internal fixation of fractures
Tubbs, N. (1981) · Injury · doi:10.1016/0020-1383(81)90078-4 · Cited by 326
Effect of dynamization on gap healing of diaphyseal fractures under external fixation
Claes, L., Wilke, H.-J., Augat, P., Rübenacker, S., & Margevicius, K. (1995) · Clinical Biomechanics · doi:10.1016/0268-0033(95)99799-8 · Cited by 237
Self-citationWu, J. J., Shyr, H. S., Chao, E. Y., & Kelly, P. J. (1984) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-198466080-00015 · Cited by 199
Early, Full Weightbearing With Flexible Fixation Delays Fracture Healing
Augat, P., Merk, J., Ignatius, A. A., Margevicius, K. J., Bauer, G. J., Rosenbaum, D., & Claes, L. (1996) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199607000-00031 · Cited by 142
Self-citationEFFECTS OF AXIAL DYNAMIZATION ON BONE HEALING
Egger, E. L., Gottsauner‐Wolf, F., Palmer, J., Aro, H. T., & Chao, E. Y. S. (1993) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-199302000-00001 · Cited by 130
Tibial external fixation, weight bearing, and fracture movement
KERSHAW, C. J., CUNNINGHAM, J. L., & KENWRIGHT, J. (1993) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199308000-00005 · Cited by 124
Quantitative Assessment of Experimental Fracture Repair by Peripheral Computed Tomography
Augat, P., Merk, J., Genant, H. K., & Claes, L. (1997) · Calcified Tissue International · doi:10.1007/s002239900213 · Cited by 121
Self-citationCyclical micromovement and fracture healing
Noordeen, M. H. H., Lavy, C., Shergill, N., Tuite, J., & Jackson, A. M. (1995) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.77b4.7615614 · Cited by 85
The early healing of tibial osteotomies stabilized by one-plane or two-plane external fixation
Williams, E. A., Rand, J. A., An, K., Chao, E. Y. S., & Kelly, P. J. (1987) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-198769030-00006 · Cited by 60
Cited by
Nature’s hierarchical materials
Fratzl, P., & Weinkamer, R. (2007) · Progress in Materials Science · doi:10.1016/j.pmatsci.2007.06.001 · Cited by 2,800
Fracture healing under healthy and inflammatory conditions
Claes, L., Recknagel, S., & Ignatius, A. (2012) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2012.1 · Cited by 1,326
Self-citationEffects of Mechanical Factors on the Fracture Healing Process
Claes, L. E., Heigele, C. A., Neidlinger-Wilke, C., Kaspar, D., Seidl, W., Margevicius, K. J., & Augat, P. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00015 · Cited by 705
Self-citationDepartment of Orthopaedic Surgery, O. R. L., & Shapiro, F. (2008) · European Cells and Materials · doi:10.22203/ecm.v015a05 · Cited by 527
Angiogenesis in Fracture Repair
Glowacki, J. (1998) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199810001-00010 · Cited by 386
Metadata
- Authors
- Claes, L., Augat, P., Suger, G., & Wilke, H.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1997-07
- Volume
- 15
- Issue
- 4
- Pages
- 577-584
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2031948569
- Cited by
- 549
- References
- 11
- FWCI
- 5.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.