Computed tomography‐based finite element analysis predicts failure loads and fracture patterns for vertebral sections
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Computed tomography‐based finite element analysis represents a powerful research tool for investigating the mechanics of skeletal fractures. To provide evidence that this technique can be used to predict failure loads and fracture patterns for bone structures, we compared the observed and predicted failure behaviors of 18 midsagittal sections. 10 mm thick, cut from human vertebral bodies. The specimens were scanned by computed tomography, and finite element models were generated with use of empirically determined density‐property relations to assign element‐specific material properties. The specimens were loaded to failure in uniaxial compression, and the models were analyzed under matching conditions. The models provided predictions of yield load that were strongly correlated with experimentally measured values (r 2 > 0.86) and were typically within 25% of measured values. Predicted stiffness values were moderately correlated with measured values, but large absolute differences existed between them. Comparisons between regions of observed fracture and of high predicted strain indicated that strain was an accurate indicator of the pattern of local fracture in more than two‐thirds of the bone specimens. In addition, strain contour plots provided better indicators of local fracture than did stress plots in these heterogeneous bone structures. We conclude that computed tomography‐based finite element analysis can be used successfully to predict both global and local failure behavior of simplified skeletal structures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492
Cited by
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Self-citationHounsfield Units for Assessing Bone Mineral Density and Strength: A Tool for Osteoporosis Management
Schreiber, J. J., Anderson, P. A., Rosas, H. G., Buchholz, A. L., & Au, A. G. (2011) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.j.00160 · Cited by 941
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Self-citationDependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
“For example, such results would eliminate the need for the strength–density mappings, commonly used to determine regions of failure in whole bone finite element analyses (Keyak and Rossi, 2000; Lotz et al., 1991; Silva et al., 1998).”
BackgroundSelf-citationYield strain behavior of trabecular bone
Kopperdahl, D. L., & Keaveny, T. M. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00057-8 · Cited by 653
Self-citationBiomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Kopperdahl, D. L., Morgan, E. F., & Keaveny, T. M. (2002) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(01)00185-1 · Cited by 267
Self-citationKeaveny, T. M., Donley, D. W., Hoffmann, P. F., Mitlak, B. H., Glass, E. V., & San Martin, J. A. (2007) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.061011 · Cited by 258
Self-citationNonlinear Finite Element Model Predicts Vertebral Bone Strength and Fracture Site
Imai, K., Ohnishi, I., Bessho, M., & Nakamura, K. (2006) · Spine · doi:10.1097/01.brs.0000225993.57349.df · Cited by 196
“In previous studies, von Mises equivalent stress has been used as the criterion of yield.(8,10,13) For ductile materials such as metals, von Mises criterion would be effective, but for bones it seems more appropriate to use Drucker-Prager equivalent stress.”
MethodDall’Ara, E., Pahr, D., Varga, P., Kainberger, F., & Zysset, P. (2012) · Osteoporosis International · doi:10.1007/s00198-011-1568-3 · Cited by 181
“[40] Silva, MJ, Keaveny, TM, Hayes, WC (1998) Computed tomography-based finite element analysis predicts failure loads and fracture patterns for vertebral sections.”
BackgroundBanse, X., Devogelaer, J. P., Munting, E., Delloye, C., Cornu, O., & Grynpas, M. (2001) · Bone · doi:10.1016/s8756-3282(01)00425-2 · Cited by 130
Post-yield relaxation behavior of bovine cancellous bone
Burgers, T. A., Lakes, R. S., García-Rodríguez, S., Piller, G. R., & Ploeg, H.-L. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.08.005 · Cited by 10
“Finite element models have shown that cancellous bone has exhibited plastic strains in vertebral bodies (Silva et al., 1998), the proximal tibia (Taylor et al.”
Background
Metadata
- Authors
- Silva, M. J., Keaveny, T. M., & Hayes, W. C.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1998-05
- Volume
- 16
- Issue
- 3
- Pages
- 300-308
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2167941144
- Cited by
- 143
- References
- 1
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.