Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 171

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Finite‐element modeling of trabecular bone: Comparison with mechanical testing and determination of tissue modulus

Ladd, Anthony J. C., Kinney, John H., Haupt, David L., Goldstein, Steven A. · 1998 · Journal of Orthopaedic Research

Abstract

We combined three techniques—mechanical testing, three‐dimensional imaging, and finite‐element modeling—to distinguish between the contributions of architecture and tissue modulus to mechanical function in human trabecular bone. The objectives of this study were 2‐fold. The first was to assess the accuracy of micromechanical modeling of trabecular bone using high‐contrast x‐ray images of the trabecular architecture. The second was to combine finite‐element calculations with mechanical testing to infer an average tissue modulus for the specimen. Specimens from five human L1 vertebrae were mechanically tested along the three anatomic axes. The specimens were then imaged by synchrotron x‐ray tomography, and the elastic moduli of each specimen were calculated from the tomographic image by finite‐element modeling. We found that 23‐μm tomographic images resolved sufficient structural detail such that the calculated anisotropy in the elastic modulus was within the uncertainties of the experimental measurements in all cases. The tissue modulus of each specimen was then estimated by comparing the calculated mean stiffness of the specimen, averaged over the three anatomical directions, with the experimental measurement. The absolute values of the experimental elastic constants could be fitted, again within the uncertainties of the experimental measure‐ments, by a single tissue modulus of 6.6 GPa, which was the average tissue modulus of the five specimens. These observations suggest that a combination of mechanical testing, three‐dimensional imaging, and finite‐element modeling might enable the physiological variations in tissue moduli to be determined as a function of age and gender.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jor.1100160516

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 171

Metadata

Authors
Ladd, A. J. C., Kinney, J. H., Haupt, D. L., & Goldstein, S. A.
Venue
Journal of Orthopaedic Research
Publisher
Wiley
Published
1998-09
Volume
16
Issue
5
Pages
622-628
ISSN
  • 0736-0266 (ISSN-L)
  • 1554-527X
OpenAlex
W2171726833
Cited by
171
References
1
FWCI
7.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Finite‐element modeling of trabecular bone: Comparison with mechanical testing and determination of tissue modulus. https://app.cochat.ai/papers/10.1002/jor.1100160516
The paper
Ladd, A. J. C., Kinney, J. H., Haupt, D. L., & Goldstein, S. A. (1998). Finite‐element modeling of trabecular bone: Comparison with mechanical testing and determination of tissue modulus. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100160516

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.