Step activity monitor: Increased accuracy in quantifying ambulatory activity
Abstract
This study compares the accuracy of a two‐dimensional accelerometer worn on the ankle (a step activity monitor) with that of an electronic, digital pedometer worn on the belt line. Twenty‐nine human subjects were evaluated while they briskly walked 400 M, slowly walked 10 M, and ascended and descended a flight of stairs. The step activity monitor had less error in all activities; its mean absolute error was 0.54%, whereas that of the pedometer was 2.82%. The difference was more pronounced in obese subjects (body mass index greater than 30), with an overall mean absolute error of 0.48% for the step activity monitor and 6.12% for the pedometer (nearly 13 times that of the step activity monitor). For subjects with a body mass index less than 30, the step activity monitor had an overall error of 0.56% and the pedometer had an overall error of 1.56% (less than 3 times that of the step activity monitor). The absolute error of the pedometer was positively correlated with body mass index (r = 0.792, p < 0.0001) and weight (r = 0.753, p < 0.0001), whereas the error of the step activity monitor was not significantly correlated with either. Neither device was significantly biased by age, gender, or the presence of a lower‐extremity joint prosthesis. The accuracy and additional capabilities, including a real‐time memory record of activity, of the step activity monitor make it well suited for objectively quantifying ambulatory activity, especially for obese subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sequeira, M. M., Rickenbach, M., Wietlisbach, V., Tullen, B., & Schutz, Y. (1995) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117748 · Cited by 250
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Utility of Pedometers for Assessing Physical Activity: Convergent Validity
Tudor-Locke, C., Williams, J. E., Reis, J. P., & Pluto, D. (2002) · Sports Medicine · doi:10.2165/00007256-200232120-00004 · Cited by 649
Accuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089342.96098.c4 · Cited by 633
Simon, S. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.047 · Cited by 570
Challenges and Opportunities for Measuring Physical Activity in Sedentary Adults
Tudor-Locke, C. E., & Myers, A. M. (2001) · Sports Medicine · doi:10.2165/00007256-200131020-00002 · Cited by 519
Metadata
- Authors
- Shepherd, E. F., Toloza, E., McClung, C. D., & Schmalzried, T. P.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1999-09
- Volume
- 17
- Issue
- 5
- Pages
- 703-708
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1965981125
- Cited by
- 182
- References
- 1
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Step activity monitor: Increased accuracy in quantifying ambulatory activity. https://app.cochat.ai/papers/10.1002/jor.1100170512
- The paper
- Shepherd, E. F., Toloza, E., McClung, C. D., & Schmalzried, T. P. (1999). Step activity monitor: Increased accuracy in quantifying ambulatory activity. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100170512
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.