Step activity monitor: Increased accuracy in quantifying ambulatory activity
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This study compares the accuracy of a two‐dimensional accelerometer worn on the ankle (a step activity monitor) with that of an electronic, digital pedometer worn on the belt line. Twenty‐nine human subjects were evaluated while they briskly walked 400 M, slowly walked 10 M, and ascended and descended a flight of stairs. The step activity monitor had less error in all activities; its mean absolute error was 0.54%, whereas that of the pedometer was 2.82%. The difference was more pronounced in obese subjects (body mass index greater than 30), with an overall mean absolute error of 0.48% for the step activity monitor and 6.12% for the pedometer (nearly 13 times that of the step activity monitor). For subjects with a body mass index less than 30, the step activity monitor had an overall error of 0.56% and the pedometer had an overall error of 1.56% (less than 3 times that of the step activity monitor). The absolute error of the pedometer was positively correlated with body mass index (r = 0.792, p < 0.0001) and weight (r = 0.753, p < 0.0001), whereas the error of the step activity monitor was not significantly correlated with either. Neither device was significantly biased by age, gender, or the presence of a lower‐extremity joint prosthesis. The accuracy and additional capabilities, including a real‐time memory record of activity, of the step activity monitor make it well suited for objectively quantifying ambulatory activity, especially for obese subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sequeira, M. M., Rickenbach, M., Wietlisbach, V., Tullen, B., & Schutz, Y. (1995) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a117748 · Cited by 250
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Utility of Pedometers for Assessing Physical Activity: Convergent Validity
Tudor-Locke, C., Williams, J. E., Reis, J. P., & Pluto, D. (2002) · Sports Medicine · doi:10.2165/00007256-200232120-00004 · Cited by 649
Accuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089342.96098.c4 · Cited by 633
Simon, S. R. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.02.047 · Cited by 570
Challenges and Opportunities for Measuring Physical Activity in Sedentary Adults
Tudor-Locke, C. E., & Myers, A. M. (2001) · Sports Medicine · doi:10.2165/00007256-200131020-00002 · Cited by 519
Tudor-Locke, C. E., & Myers, A. M. (2001) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2001.10608926 · Cited by 518
The validity and reliability of a novel activity monitor as a measure of walking
Ryan, C. G., Grant, P. M., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.027276 · Cited by 490
Wear Is a Function of Use, Not Time
Schmalzried, T. P., Shepherd, E. F., Dorey, F. J., Jackson, W. O., dela Rosa, M., Fa???vae, F., McKellop, H. A., McClung, C. D., Martell, J., Moreland, J. R., et al. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200012000-00005 · Cited by 474
Self-citationDowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Comparison of Pedometer and Accelerometer Accuracy under Controlled Conditions
LE MASURIER, G. C., & TUDOR-LOCKE, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064996.63632.10 · Cited by 360
Spring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults
CROUTER, S. E., SCHNEIDER, P. L., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000181677.36658.a8 · Cited by 295
Commercially available pedometers: considerations for accurate step counting
Melanson, E. L., Knoll, J. R., Bell, M. L., Donahoo, W. T., Hill, J. O., Nysse, L. J., Lanningham-Foster, L., Peters, J. C., & Levine, J. A. (2004) · Preventive Medicine · doi:10.1016/j.ypmed.2004.01.032 · Cited by 280
Risk Factors Affecting Outcome of Metal-on-Metal Surface Arthroplasty of the Hip
Beaul??, P. E., Dorey, F. J., LeDuff, M., Gruen, T., & Amstutz, H. C. (2004) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200401000-00015 · Cited by 254
Motion Sensor Accuracy under Controlled and Free-Living Conditions
LE MASURIER, G. C., LEE, S. M., & TUDOR-LOCKE, C. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126777.50188.73 · Cited by 229
Average patient walking activity approaches 2 million cycles per year
Silva, M., Shepherd, E. F., Jackson, W. O., Dorey, F. J., & Schmalzried, T. P. (2002) · The Journal of Arthroplasty · doi:10.1054/arth.2002.32699 · Cited by 220
Self-citationUsing Activity Monitors to Measure Physical Activity in Free-Living Conditions
Berlin, J. E., Storti, K. L., & Brach, J. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.8.1137 · Cited by 209
The LEAPS Investigative Team, Duncan, P. W., Sullivan, K. J., Behrman, A. L., Azen, S. P., Wu, S. S., Nadeau, S. E., Dobkin, B. H., Rose, D. K., & Tilson, J. K. (2007) · BMC Neurology · doi:10.1186/1471-2377-7-39 · Cited by 205
“The device has a 99% accuracy for recording steps with a variety of gait patterns [27-29].”
Haeuber, E., Shaughnessy, M., Forrester, L. W., Coleman, K. L., & Macko, R. F. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.11.035 · Cited by 182
Maluf, K. S., & Mueller, M. J. (2003) · Clinical Biomechanics · doi:10.1016/s0268-0033(03)00118-9 · Cited by 177
“These features improve the accuracy of data obtained from subjects who are obese or who exhibit gait impairments (Coleman et al., 1999; Shepherd et al., 1999).”
BackgroundPosition-sensing technologies for movement analysis in stroke rehabilitation
Zheng, H., Black, N. D., & Harris, N. D. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344720 · Cited by 165
Evaluation of Activity Monitors in Controlled and Free-Living Environments
FEITO, Y., BASSETT, D. R., & THOMPSON, D. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182351913 · Cited by 159
Capturing Ambulatory Activity Decline in Parkinson's Disease
Cavanaugh, J. T., Ellis, T. D., Earhart, G. M., Ford, M. P., Foreman, K. B., & Dibble, L. E. (2012) · Journal of Neurologic Physical Therapy · doi:10.1097/npt.0b013e318254ba7a · Cited by 141
Comparison of two waist-mounted and two ankle-mounted electronic pedometers
Karabulut, M., Crouter, S. E., & Bassett, D. R. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0018-3 · Cited by 139
Mudge, S., Stott, N. S., & Walt, S. E. (2007) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.07.039 · Cited by 105
Effects of Body Mass Index and Step Rate on Pedometer Error in a Free-Living Environment
TYO, B. M., FITZHUGH, E. C., BASSETT, D. R., JOHN, D., FEITO, Y., & THOMPSON, D. L. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181e9b133 · Cited by 46
Metadata
- Authors
- Shepherd, E. F., Toloza, E., McClung, C. D., & Schmalzried, T. P.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1999-09
- Volume
- 17
- Issue
- 5
- Pages
- 703-708
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W1965981125
- Cited by
- 182
- References
- 1
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.