The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Measurement and removal of adherent endotoxin from titanium particles and implant surfaces
Abstract
Aseptic loosening is thought to be due primarily to osteolysis induced by cytokines and prostaglandins that are produced in response to implant‐derived wear particles. Because endotoxin has many of the same effects as have been reported for wear particles, we hypothesized that adherent endotoxin may be responsible for the biological responses induced by wear particles. We demonstrated the presence of significant levels of adherent endotoxin on commonly used preparations of titanium particles as well as on titanium and titanium‐alloy implant surfaces. In contrast, supernatants obtained by centrifugation of particle suspensions contained approximately 1% as much endotoxin as did the particles. Therefore, it is erroneous to assume that particles do not contain endotoxin on the basis of data that it cannot be detected in their supernatants or filtrates. These results emphasize the importance of considering the potential role of adherent endotoxin when examining the in vitro effects of wear particles and the in vivo performance of orthopaedic implants. We also developed a protocol that removed more than 99.94% of the adherent endotoxin from the titanium particles without detectably affecting their size or shape. The removal of adherent endotoxin will allow comparison of the biological responses induced by particles with or without adherent endotoxin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human monocyte/macrophage activation and interleukin 1 generation by biomedical polymers
Miller, K. M., & Anderson, J. M. (1988) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820220805 · Cited by 156
Cited by
Gorbet, M. B., & Sefton, M. V. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.023 · Cited by 1,347
Aseptic loosening, not only a question of wear: A review of different theories
Sundfeldt, M., V Carlsson, L., B Johansson, C., Thomsen, P., & Gretzer, C. (2006) · Acta Orthopaedica · doi:10.1080/17453670610045902 · Cited by 622
In vitro assessments of nanomaterial toxicity
Jones, C. F., & Grainger, D. W. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.03.005 · Cited by 554
Extracellular matrix-based biomaterial scaffolds and the host response
Aamodt, J. M., & Grainger, D. W. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.02.003 · Cited by 509
Endotoxin: The uninvited guest
Gorbet, M. B., & Sefton, M. V. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.04.063 · Cited by 410
Metadata
- Authors
- Ragab, A. A., Van De Motter, R., Lavish, S. A., Goldberg, V. M., Ninomiya, J. T., Carlin, C. R., & Greenfield, E. M.
- Venue
- Journal of Orthopaedic Research
- Publisher
- Wiley
- Published
- 1999-11
- Volume
- 17
- Issue
- 6
- Pages
- 803-809
- ISSN
- 0736-0266 (ISSN-L)
- 1554-527X
- OpenAlex
- W2072837540
- Cited by
- 191
- References
- 1
- FWCI
- 6.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurement and removal of adherent endotoxin from titanium particles and implant surfaces. https://app.cochat.ai/papers/10.1002/jor.1100170603
- The paper
- Ragab, A. A., Van De Motter, R., Lavish, S. A., Goldberg, V. M., Ninomiya, J. T., Carlin, C. R., & Greenfield, E. M. (1999). Measurement and removal of adherent endotoxin from titanium particles and implant surfaces. Journal of Orthopaedic Research. https://doi.org/10.1002/jor.1100170603
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.