The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Detection of single lipid bilayers with coherent anti‐Stokes Raman scattering (CARS) microscopy
Abstract
We investigated vibrational imaging of phospholipid bilayers with CARS microscopy. Single lipid membranes of supported bilayers, giant unilamellar vesicles and intact erythrocyte membrane are detected with the strong resonant signal of the C–H stretching vibration. In addition, it is shown that the CARS signal field of the lipids near the glass/water interface is amplified through mixing with the back‐reflected non‐resonant CARS field of the glass coverslip. Furthermore, interference effects between two separate bilayers are observed, allowing intermembrane distances to be determined beyond the diffraction‐limited resolution of the microscope. Copyright © 2003 John Wiley & Sons, Ltd.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydration forces between phospholipid bilayers
Rand, R. P., & Parsegian, V. A. (1989) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(89)90010-5 · Cited by 1,125
Cited by
Nanochemistry and Nanomedicine for Nanoparticle-based Diagnostics and Therapy
Chen, G., Roy, I., Yang, C., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00148 · Cited by 1,499
Coherent Anti-Stokes Raman Scattering Microscopy: Chemical Imaging for Biology and Medicine
Evans, C. L., & Xie, X. S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112754 · Cited by 1,150
Self-citationCoherent Anti-Stokes Raman Scattering Microscopy: Instrumentation, Theory, and Applications
Cheng, J.-X., & Xie, X. S. (2004) · The Journal of Physical Chemistry B · doi:10.1021/jp035693v · Cited by 963
Self-citationChemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Self-citationVibrational spectroscopic imaging of living systems: An emerging platform for biology and medicine
Cheng, J.-X., & Xie, X. S. (2015) · Science · doi:10.1126/science.aaa8870 · Cited by 874
Self-citation
Metadata
- Authors
- Potma, E. O., & Xie, X. S.
- Venue
- Journal of Raman Spectroscopy
- Publisher
- Wiley
- Published
- 2003-09
- Volume
- 34
- Issue
- 9
- Pages
- 642-650
- ISSN
- 0377-0486 (ISSN-L)
- 1097-4555
- OpenAlex
- W2160653509
- Cited by
- 161
- References
- 1
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of single lipid bilayers with coherent anti‐Stokes Raman scattering (CARS) microscopy. https://app.cochat.ai/papers/10.1002/jrs.1045
- The paper
- Potma, E. O., & Xie, X. S. (2003). Detection of single lipid bilayers with coherent anti‐Stokes Raman scattering (CARS) microscopy. Journal of Raman Spectroscopy. https://doi.org/10.1002/jrs.1045
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.