Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 354

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Surface‐enhanced Raman sensors: early history and the development of sensors for quantitative biowarfare agent and glucose detection

Haynes, Christy L., Yonzon, Chanda Ranjit, Zhang, Xiaoyu, Van Duyne, Richard P.·2005·Journal of Raman Spectroscopy

Abstract

Surface‐enhanced Raman spectroscopy (SERS) is a powerful technique for the sensitive and selective detection of low‐concentration analytes. This paper includes a discussion of the early history of SERS, the concepts that must be appreciated to optimize the intensity of SERS and the development of SERS‐based sensors. In order to achieve the lowest limits of detection, both the relationship between surface nanostructure and laser excitation wavelength, as well as the analyte/surface binding chemistry, must be carefully optimized. This work exploits the highly tunable nature of nanoparticle optical properties to establish the first set of optimization conditions. The SERS enhancement factor, EFSERS, is optimized when the energy of the localized surface plasmon resonance (LSPR) lies between the energy of the excitation wavelength and the energy of the vibrational band of interest. With the narrow LSPRs used in this work, it is straightforward to achieve EFSERS ∼ 10 8. These optimization conditions were exploited to develop SERS‐based sensors for two important target molecules: a Bacillus anthracis biomarker and glucose in a serum protein mixture. Using these optimized film‐over‐nanosphere surfaces, an inexpensive, portable Raman spectrometer was used successfully to detect the infectious dose of Bacillus subtilis spores with only a 5‐s data collection. The biomarker used to detect the Bacillus subtilis spores binds irreversibly to SERS substrates, whereas other important biomolecules, such as glucose, do not have any measurable binding affinity to a bare silver surface. To overcome this difficulty, a biocompatible partition layer was self‐assembled on the SERS substrate before exposure to the analyte solution. Using the partition layer approach to concentrate glucose near the SERS‐active substrate, physiological glucose concentrations can be detected even in the presence of interfering serum proteins. Copyright © 2005 John Wiley & Sons, Ltd.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jrs.1376

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 354

Metadata

Authors
Haynes, C. L., Yonzon, C. R., Zhang, X., & Van Duyne, R. P.
Venue
Journal of Raman Spectroscopy
Publisher
Wiley
Published
2005-06
Volume
36
Issue
6-7
Pages
471-484
ISSN
  • 0377-0486 (ISSN-L)
  • 1097-4555
OpenAlex
W1967063163
Cited by
354
References
4
FWCI
14.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Surface‐enhanced Raman sensors: early history and the development of sensors for quantitative biowarfare agent and glucose detection. https://app.cochat.ai/papers/10.1002/jrs.1376
The paper
Haynes, C. L., Yonzon, C. R., Zhang, X., & Van Duyne, R. P. (2005). Surface‐enhanced Raman sensors: early history and the development of sensors for quantitative biowarfare agent and glucose detection. Journal of Raman Spectroscopy. https://doi.org/10.1002/jrs.1376

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.