Cited by 376Gold and Silver Nanoparticles Synthesis and ApplicationsSpectroscopy Techniques in Biomedical and Chemical ResearchElectrochemical sensors and biosensors

A Glucose Biosensor Based on Surface-Enhanced Raman Scattering: Improved Partition Layer, Temporal Stability, Reversibility, and Resistance to Serum Protein Interference

Yonzon, Chanda Ranjit, Haynes, Christy L., Zhang, Xiaoyu, Walsh,, Joseph T., Van Duyne, Richard P.·2004·Analytical Chemistry

Abstract

This work updates the recent progress made toward fabricating a real-time, quantitative, and biocompatible glucose sensor based on surface-enhanced Raman scattering (SERS). The sensor design relies on an alkanethiolate tri(ethylene glycol) monolayer that acts as a partition layer, preconcentrating glucose near a SERS-active surface. Chemometric analysis of the captured SERS spectra demonstrates that glucose is quantitatively detected in the physiological concentration range (0-450 mg/dL, 0-25 mM). In fact, 94% of the predicted glucose concentrations fall within regions A and B of the Clarke error grid, making acceptable predictions in a clinically relevant range. The data presented herein also demonstrate that the glucose sensor provides stable SERS spectra for at least 3 days, making the SERS substrate a candidate for implantable sensing. Glucose sensor reversibility and reusability is evaluated as the sensor is alternately exposed to glucose and saline solutions; after each cycle, difference spectra reveal that the partitioning process is largely reversible. Finally, the SERS glucose sensor successfully partitions glucose even when challenged with bovine serum albumin, a serum protein mimic.

Integrity signals

Registry

Crossref · 10.1021/ac035134k

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Surface enhanced Raman spectroscopy dramatically shortens acquisition times and improves sensitivity and limit of detection.

    “Recent advances have demonstrated that surface enhanced Raman spectroscopy (SERS) dramatically decreases acquisition times with concomitant improvements in both sensitivity and limit of detection.45–46”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Yonzon, C. R., Haynes, C. L., Zhang, X., Walsh, & Van Duyne, R. P.
Affiliations
  • Northwestern University (US)
  • Department of Chemistry and Department of Biomedical Engineering, Northwestern University, 2145 Sheridan Road, Evanston, Illinois 60208-3113
Venue
Analytical Chemistry
Published
2003-11-25
Volume
76
Issue
1
Pages
78-85
ISSN
  • 0003-2700 (ISSN-L)
  • 1520-6882
OpenAlex
W2014133708
Cited by
376
References
36
Citations by year
2026: 3 · 2025: 5 · 2024: 6 · 2023: 14 · 2022: 9 · 2021: 8 · 2020: 15 · 2019: 12 · 2018: 13 · 2017: 22 · 2016: 12 · 2015: 19 · 2014: 21 · 2013: 26 · 2012: 25
FWCI
13.20
Type
journal article
Language
en
Open access
closed
Locations
  • Analytical Chemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Northwestern University
  • National Institutes of Health (5r01ey013002-03)
  • Multidisciplinary University Research Initiative
  • National Eye Institute (EY13015, R24EY013015, EY13002)
  • Air Force Office of Scientific Research
Topics
  • Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Gold and Silver Nanoparticles Synthesis and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
Keywords
glucose biosensor, surface-enhanced Raman scattering, bovine serum albumin, sensor reversibility, sensor reusability, temporal stability, chemometric analysis, Clarke error grid
MeSH terms
Animals, Blood Proteins, Cattle, Drug Stability, Glucose, Spectrum Analysis, Raman, Time Factors, Biosensing Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review