The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Tumor measurement in the nude mouse
Abstract
In this study, the pitfalls of tumor measurement in the nude mouse were evaluated. Regarding intermethod variation, diameters of subcutaneous tumors in nude mice were expressed as length, area, and volume; tumor weights were also recorded. These measurements were all compared to a reference standard: water displacement volume. Estimates of area and volume derived from caliper measurements correlated well with water displacement volume (r = 0.97 and 0.98, respectively). At necropsy, tumor weight was the most consistent and reproducible reflection of tumor volume (r = 1.0000). Regarding interobserver variation, mean absolute difference among volumes determined by several investigators who measured the same tumors in living animals was determined. This averaged 15% of the mean calculated volume. Regarding intraobserver variation, observers measured four separate masses in nude mice eight times each. The observers were prevented from realizing that the same animals were being repeatedly evaluated. Volumes were compared in order to quantify the average variation that occurs when a single investigator repeatedly measures the same mass. When large masses were measured, this error was 7%; when small masses were measured, the error was 27%. Recommendations are made for future work employing tumor measurement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Handbook of Chemistry and Physics.
(1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-6-934_3 · Cited by 2,559
Attia, M. A., & Weiss, D. W. (1966) · PubMed · Cited by 312
The effect of measuring error on the results of therapeutic trials in advanced cancer
Moertel, C. G., & Hanley, J. A. (1976) · Cancer · doi:10.1002/1097-0142(197607)38:1<388::aid-cncr2820380156>3.0.co;2-a · Cited by 257
BULLARD, D. E., SCHOLD, S. C., BIGNER, S. H., & BIGNER, D. D. (1981) · Journal of Neuropathology and Experimental Neurology · doi:10.1097/00005072-198107000-00005 · Cited by 158
Case for using only maximum diameter in measuring tumors.
Gurland, J., & JOHNSON, R. O. (1966) · PubMed · Cited by 21
Function of the Thymus and Growth of Tumour Homograft
PERRI, G. C., Faulk, M., SHAPIRO, E., Mellors, J. W., & Money, W. L. (1963) · Nature · doi:10.1038/2001294a0 · Cited by 20
What shall we measure on whom: why?
SCHNEIDERMAN, M. A., & Mj, K. (1966) · PubMed · Cited by 7
Cited by
Determination of subcutaneous tumor size in athymic (nude) mice
Tomayko, M. M., & Reynolds, C. P. (1989) · Cancer Chemotherapy and Pharmacology · doi:10.1007/bf00300234 · Cited by 1,830
Cloning and characterization of FGF23 as a causative factor of tumor-induced osteomalacia
Shimada, T., Mizutani, S., Muto, T., Yoneya, T., Hino, R., Takeda, S., Takeuchi, Y., Fujita, T., Fukumoto, S., & Yamashita, T. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.101545198 · Cited by 1,457
Pharmacological Rescue of Mutant p53 Conformation and Function
Foster, B. A., Coffey, H. A., Morin, M. J., & Rastinejad, F. (1999) · Science · doi:10.1126/science.286.5449.2507 · Cited by 799
Theranostic Fluorescent Probes
Sharma, A., Verwilst, P., Li, M., Ma, D., Singh, N., Yoo, J., Kim, Y., Yang, Y., Zhu, J.-H., Huang, H., et al. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00778 · Cited by 499
Tian, J., Ding, L., Xu, H.-J., Shen, Z., Ju, H., Jia, L., Bao, L., & Yu, J.-S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja408286k · Cited by 416
Metadata
- Authors
- Euhus, D. M., Hudd, C., Laregina, M. C., & Johnson, F. E.
- Venue
- Journal of Surgical Oncology
- Publisher
- Wiley
- Published
- 1986-04
- Volume
- 31
- Issue
- 4
- Pages
- 229-234
- ISSN
- 0022-4790 (ISSN-L)
- 1096-9098
- OpenAlex
- W2128569116
- Cited by
- 605
- References
- 7
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tumor measurement in the nude mouse. https://app.cochat.ai/papers/10.1002/jso.2930310402
- The paper
- Euhus, D. M., Hudd, C., Laregina, M. C., & Johnson, F. E. (1986). Tumor measurement in the nude mouse. Journal of Surgical Oncology. https://doi.org/10.1002/jso.2930310402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.