Vortex‐assisted liquid–liquid microextraction combined with gas chromatography‐mass spectrometry for the determination of organophosphate pesticides in environmental water samples and wines
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A simple vortex‐assisted liquid–liquid microextraction protocol followed by GC‐MS is proposed for the determination of 12 organophosphate pesticides residues in environmental water samples and wines. The sample pretreatment employs the usage of low‐density organic solvent. The parameters affecting the extraction efficiency (type and volume of organic extraction solvent, sample pH, ionic strength, extraction time, and centrifugation speed) were carefully examined. A mild emulsification process was involved by the addition of 40 μL toluene into 10 mL sample followed by sequential vortex‐based agitation and manual shaking for 3 min. Following the extraction, the pesticide‐rich organic solvent was recovered by centrifugation at 4000 rpm for 5 min. A fraction of the floated toluene was then collected and analyzed by GC‐MS in SIM mode. Under the optimized conditions, the enrichment factor ranged between 65 and 389. Satisfactory linearity was observed for all pesticides tested with correlation coefficients higher than 0.9945 while the LOD s were in the range of 2–11 ng L−1. The main advantages of the proposed method are the simplicity of operation, rapidity, low cost, and high sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Determination of organic compounds in water using dispersive liquid–liquid microextraction
Rezaee, M., Assadi, Y., Milani Hosseini, M.-R., Aghaee, E., Ahmadi, F., & Berijani, S. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.03.007 · Cited by 3,402
Regueiro, J., Llompart, M., Garcia-Jares, C., Garcia-Monteagudo, J. C., & Cela, R. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2008.02.091 · Cited by 547
Kocúrová, L., Balogh, I. S., Šandrejová, J., & Andruch, V. (2012) · Microchemical Journal · doi:10.1016/j.microc.2011.12.002 · Cited by 271
Liquid-phase microextraction techniques within the framework of green chemistry
Pena-Pereira, F., Lavilla, I., & Bendicho, C. (2010) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.02.016 · Cited by 221
Chen, H., Chen, H., Ying, J., Huang, J., & Liao, L. (2009) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.10.068 · Cited by 184
Cited by
Kaushal, J., Khatri, M., & Arya, S. K. (2021) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2020.111483 · Cited by 323
Ten years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
“Organophosphate pesticides Water, wine VALLME GC-MS 2–11 ng L¡1 (653)”
BackgroundFarajzadeh, M. A., Sattari Dabbagh, M., & Yadeghari, A. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700052 · Cited by 72
Dal Bosco, C., Mariani, F., & Gentili, A. (2022) · Molecules · doi:10.3390/molecules27030908 · Cited by 28
Metadata
- Authors
- Zacharis, C. K., Christophoridis, C., & Fytianos, K.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2012-08-15
- Volume
- 35
- Issue
- 18
- Pages
- 2422-2429
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W1972103941
- Cited by
- 73
- References
- 5
- FWCI
- 8.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.