Abstract

The optimisation of focused ultrasound extraction and supercritical fluid extraction of volatile oils and cannabinoids from marihuana has been accomplished by experimental design approach. On the one hand, the focused ultrasound extraction method of volatile compounds and cannabinoids was studied based on the optimisation of cyclohexane and isopropanol solvent mixtures, and the instrumental variables. The optimal working conditions were finally fixed at isopropanol/cyclohexane 1:1 mixture, cycles (3 s−1), amplitude (80%) and sonication time (5 min). On the other hand, the supercritical fluid extraction method was optimised in order to obtain a deterpenation of the plant and a subsequent cannabinoid extraction. For this purpose, pressure, temperature, flow and co‐solvent percentage were optimised and the optimal working conditions were set at 100 bar, 35°C, 1 mL/min, no co‐solvent for the terpenes and 20% of ethanol for the cannabinoids. Based on the retention time locking GC‐MS analysis of the supercritical fluid extracts the classification of the samples according to the type of plant, the growing area and season was attained. Finally, three monoterpenes and three cannabinoids were quantified in the ranges of 0.006–6.2 μg/g and 0.96–324 mg/g, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/jssc.201201103

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 88

Metadata

Authors
Omar, J., Olivares, M., Alzaga, M., & Etxebarria, N.
Venue
Journal of Separation Science
Publisher
Wiley
Published
2013-03-15
Volume
36
Issue
8
Pages
1397-1404
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W1579321490
Cited by
88
References
3
FWCI
3.26
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimisation and characterisation of marihuana extracts obtained by supercritical fluid extraction and focused ultrasound extraction and retention time locking GC‐MS. https://app.cochat.ai/papers/10.1002/jssc.201201103
The paper
Omar, J., Olivares, M., Alzaga, M., & Etxebarria, N. (2013). Optimisation and characterisation of marihuana extracts obtained by supercritical fluid extraction and focused ultrasound extraction and retention time locking GC‐MS. Journal of Separation Science. https://doi.org/10.1002/jssc.201201103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.