Optimization of dispersive liquid–liquid microextraction with central composite design for preconcentration of chlordiazepoxide drug and its determination by HPLC‐UV
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
A simple, rapid, and sensitive method based on dispersive liquid–liquid microextraction combined with HPLC‐UV detection applied for the quantification of chlordiazepoxide in some real samples. The effect of different extraction conditions on the extraction efficiency of the chlordiazepoxide drug was investigated and optimized using central composite design as a conventional efficient tool. Optimum extraction condition values of variables were set as 210 μL chloroform, 1.8 mL methanol, 1.0 min extraction time, 5.0 min centrifugation at 5000 rpm min−1, neutral pH, 7.0% w/v NaCl. The separation was reached in less than 8.0 min using a C 18 column using isocratic binary mobile phase (acetonitrile/water (60:40, v/v)) with flow rate of 1.0 mL min−1. The linear response (r2 > 0.998) was achieved in the range of 0.005–10 μg mL−1 with detection limit 0.0005 μg mL−1. The applicability of this method for simultaneous extraction and determination of chlordiazepoxide in four different matrices (water, urine, plasma, and chlordiazepoxide tablet) were investigated using standard addition method. Average recoveries at two spiking levels were over the range of 91.3–102.5% with RSD < 5.0% (n = 3). The obtained results show that dispersive liquid–liquid microextraction combined with HPLC‐UV is a fast and simple method for the determination of chlordiazepoxide in real samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evolution of dispersive liquid–liquid microextraction method
Rezaee, M., Yamini, Y., & Faraji, M. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.088 · Cited by 971
Berijani, S., Assadi, Y., Anbia, M., Milani Hosseini, M.-R., & Aghaee, E. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2006.05.010 · Cited by 870
Fattahi, N., Assadi, Y., Hosseini, M. R. M., & Jahromi, E. Z. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.04.062 · Cited by 366
Ahmadi, F., Assadi, Y., Hosseini, S. M. R. M., & Rezaee, M. (2006) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.11.017 · Cited by 325
Xiong, C., Ruan, J., Cai, Y., & Tang, Y. (2009) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2008.11.036 · Cited by 145
Cited by
An overview of experimental designs in HPLC method development and validation
Sahu, P. K., Ramisetti, N. R., Cecchi, T., Swain, S., Patro, C. S., & Panda, J. (2018) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2017.05.006 · Cited by 392
Recent developments in dispersive liquid–liquid microextraction
Saraji, M., & Boroujeni, M. K. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7467-z · Cited by 232
Mousavi, L., Tamiji, Z., & Khoshayand, M. R. (2018) · Talanta · doi:10.1016/j.talanta.2018.08.002 · Cited by 195
Asfaram, A., Ghaedi, M., Goudarzi, A., Soylak, M., & Mehdizadeh Langroodi, S. (2015) · New Journal of Chemistry · doi:10.1039/c5nj01730k · Cited by 161
Self-citationTen years of dispersive liquid–liquid microextraction and derived techniques
Campillo, N., Viñas, P., Šandrejová, J., & Andruch, V. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1224240 · Cited by 102
Pourbasheer, E., Qasemi, F., Rouhi, M., Azari, Z., & Ganjali, M. R. (2017) · Journal of Separation Science · doi:10.1002/jssc.201601453 · Cited by 10
Metadata
- Authors
- Khodadoust, S., & Ghaedi, M.
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2013-04-27
- Volume
- 36
- Issue
- 11
- Pages
- 1734-1742
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W1897410693
- Cited by
- 102
- References
- 5
- FWCI
- 12.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.