The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
Separation of intact proteins on γ‐ray‐induced polymethacrylate monolithic columns: A highly permeable stationary phase with high peak capacity for capillary high‐performance liquid chromatography with high‐resolution mass spectrometry
Abstract
Polymethacrylate‐based monolithic capillary columns, prepared by γ‐radiation‐induced polymerization, were used to optimize the experimental conditions (nature of the organic modifiers, the content of trifluoroacetic acid and the column temperature) in the separation of nine standard proteins with different hydrophobicities and a wide range of molecular weights. Because of the excellent permeability of the monolithic columns, an ion‐pair reversed‐phase capillary liquid chromatography with high‐resolution mass spectrometry method has been developed by coupling the column directly to the mass spectrometer without a flow‐split and using a standard electrospray interface. Additionally, the high working flow and concomitant high efficiency of these columns allowed us to employ a longer column (up to 50 cm) and achieve a peak capacity value superior to 1000. This work is motivated by the need to develop new materials for high‐resolution chromatographic separation that combine chemical stability at elevated temperatures (up to 75°C) and a broad pH range, with a high peak capacity value. The advantage of the γ‐ray‐induced monolithic column lies in the batch‐to‐batch reproducibility and long‐term high‐temperature stability. Their proven high loading capacity, recovery, good selectivity and high permeability, moreover, compared well with that of a commercially available poly(styrene‐divinylbenzene) monolithic column, which confirms that such monolithic supports might facilitate analysis in proteomics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“On the other hand, monolithic columns offer high-resolution protein separation with low backpressure [71].”
From Top-down proteomics: challenges, innovations, and applications in basic and clinical research (2020) · cites this paper as [71]
Citations
Cites
Continuous rods of macroporous polymer as high-performance liquid chromatography separation media
Svec, F., & Frechet, J. M. J. (1992) · Analytical Chemistry · doi:10.1021/ac00031a022 · Cited by 951
Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry
Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W. (1999) · Journal of the American Chemical Society · doi:10.1021/ja973655h · Cited by 605
Porous polymer monoliths: Amazingly wide variety of techniques enabling their preparation
Svec, F. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.09.073 · Cited by 577
Top Down proteomics: Facts and perspectives
Catherman, A. D., Skinner, O. S., & Kelleher, N. L. (2014) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2014.02.041 · Cited by 507
D. Antia, F., & Horváth, C. (1988) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)82158-0 · Cited by 254
Premstaller, A., Oberacher, H., Walcher, W., Timperio, A. M., Zolla, L., Chervet, J.-P., Cavusoglu, N., van Dorsselaer, A., & Huber, C. G. (2001) · Analytical Chemistry · doi:10.1021/ac010046q · Cited by 209
Intact protein analysis in the biopharmaceutical field
Staub, A., Guillarme, D., Schappler, J., Veuthey, J.-L., & Rudaz, S. (2011) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2011.01.031 · Cited by 180
Peak capacity in unidimensional chromatography
Neue, U. D. (2008) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.11.113 · Cited by 161
Fundamentals for LC Miniaturization
Desmet, G., & Eeltink, S. (2013) · Analytical Chemistry · doi:10.1021/ac303317c · Cited by 159
Urban, J., Švec, F., & Fréchet, J. M. J. (2010) · Analytical Chemistry · doi:10.1021/ac100008n · Cited by 153
Nischang, I., & Brüggemann, O. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.06.021 · Cited by 123
Shibue, M., Mant, C. T., & Hodges, R. S. (2005) · Journal of Chromatography A · doi:10.1016/j.chroma.2005.03.035 · Cited by 106
Vellaichamy, A., Tran, J. C., Catherman, A. D., Lee, J. E., Kellie, J. F., Sweet, S. M. M., Zamdborg, L., Thomas, P. M., Ahlf, D. R., Durbin, K. R., et al. (2010) · Analytical Chemistry · doi:10.1021/ac9021083 · Cited by 100
Capriotti, A. L., Cavaliere, C., Foglia, P., Samperi, R., & Laganà, A. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.05.094 · Cited by 95
Self-citationWu, S., Lourette, N. M., Tolić, N., Zhao, R., Robinson, E. W., Tolmachev, A. V., Smith, R. D., & Paša‐Tolić, L. (2009) · Journal of Proteome Research · doi:10.1021/pr800720d · Cited by 94
Sáfrány, Á., Beiler, B., László, K., & Švec, F. (2005) · Polymer · doi:10.1016/j.polymer.2005.02.024 · Cited by 90
Harris, K. R. (1982) · Journal of the Chemical Society Faraday Transactions 1 Physical Chemistry in Condensed Phases · doi:10.1039/f19827802265 · Cited by 89
Rudd, P. M., Scragg, I. G., Coghill, E., & Dwek, R. A. (1992) · Glycoconjugate Journal · doi:10.1007/bf00731704 · Cited by 85
García, M. C., Hogenboom, A. C., Zappey, H. W., & Irth, H. (2002) · Journal of Chromatography A · doi:10.1016/s0021-9673(02)00345-x · Cited by 80
Fekete, S., Berky, R., Fekete, J., Veuthey, J., & Guillarme, D. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.03.018 · Cited by 71
Separation of intact proteins on porous layer open tubular (PLOT) columns
Røgeberg, M., Wilson, S. R., Greibrokk, T., & Lundanes, E. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.02.025 · Cited by 64
Organic monoliths for high‐performance reversed‐phase liquid chromatography
Liu, K., Aggarwal, P., Lawson, J. S., Tolley, H. D., & Lee, M. L. (2013) · Journal of Separation Science · doi:10.1002/jssc.201300431 · Cited by 62
Optimized superficially porous particles for protein separations
Schuster, S. A., Wagner, B. M., Boyes, B. E., & Kirkland, J. J. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.09.054 · Cited by 61
Grafnetter, J., Coufal, P., Tesařová, E., Suchánková, J., Bosáková, Z., & Ševčı́k, J. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.08.009 · Cited by 60
Böhm, V. (2001) · Journal of Separation Science · doi:10.1002/1615-9314(20011201)24:12<921::aid-jssc921>3.0.co;2-2 · Cited by 58
Developing top down proteomics to maximize proteome and sequence coverage from cells and tissues
Ahlf, D. R., Thomas, P. M., & Kelleher, N. L. (2013) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2013.07.028 · Cited by 52
High‐efficiency nano‐ and micro‐HPLC – High‐resolution Orbitrap‐MS platform for top‐down proteomics
Mohr, J. H., Swart, R., Samonig, M., Böhm, G., & Huber, C. G. (2010) · PROTEOMICS · doi:10.1002/pmic.201000341 · Cited by 47
Shu, S., Kobayashi, H., Kojima, N., Sabarudin, A., & Umemura, T. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.05.104 · Cited by 47
Jandera, P., Staňková, M., Škeříková, V., & Urban, J. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.12.003 · Cited by 47
Eeltink, S., Wouters, B., Desmet, G., Ursem, M., Blinco, D., Kemp, G. D., & Treumann, A. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.06.049 · Cited by 45
Røgeberg, M., Vehus, T. S., Grutle, L. A., Greibrokk, T., Wilson, S. R., & Lundanes, E. (2013) · Journal of Separation Science · doi:10.1002/jssc.201300499 · Cited by 44
Analysis of peptides and proteins using sub-2μm fully porous and sub 3-μm shell particles
Staub, A., Zurlino, D., Rudaz, S. L., Veuthey, J., & Guillarme, D. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.07.051 · Cited by 41
Eeltink, S., Dolman, S., Detobel, F., Desmet, G., Swart, R., & Ursem, M. (2009) · Journal of Separation Science · doi:10.1002/jssc.200900068 · Cited by 40
Liu, Z., Ou, J., Liu, Z., Liu, J., Lin, H., Wang, F., & Zou, H. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.09.004 · Cited by 40
Kučerová, Z., Szumski, M., Buszewski, B., & Jandera, P. (2007) · Journal of Separation Science · doi:10.1002/jssc.200700346 · Cited by 39
Nanostructured porous polymer monolithic columns for capillary liquid chromatography of peptides
Vaast, A., Terryn, H. A., Švec, F., & Eeltink, S. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.11.063 · Cited by 38
Silica‐based and organic monolithic capillary columns for LC: Recent trends in proteomics
Rozenbrand, J., & van Bennekom, W. P. (2011) · Journal of Separation Science · doi:10.1002/jssc.201100294 · Cited by 37
Beiler, B., Vincze, Á., Švec, F., & Sáfrány, Á. (2007) · Polymer · doi:10.1016/j.polymer.2007.04.002 · Cited by 37
Grafnetter, J., Coufal, P., TESAROVA, E., et al. (2004) · Journal of Chromatography A · doi:10.1016/s0021-9673(04)01337-8 · Cited by 34
Dauly, C., Perlman, D. H., Costello, C. E., & McComb, M. E. (2006) · Journal of Proteome Research · doi:10.1021/pr060108z · Cited by 33
Pierri, G., Kotoni, D., Simone, P., Villani, C., Pepe, G., Campiglia, P., Dugo, P., & Gasparrini, F. (2013) · Journal of Chromatography A · doi:10.1016/j.chroma.2013.08.083 · Cited by 31
Self-citationHuber, C. G., Kleindienst, G., & Bonn, G. K. (1997) · Chromatographia · doi:10.1007/bf02466324 · Cited by 30
Rozenbrand, J., de Jong, G. J., & van Bennekom, W. P. (2011) · Journal of Separation Science · doi:10.1002/jssc.201100151 · Cited by 29
Causon, T. J., Nordborg, A., Shellie, R. A., & Hilder, E. F. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2010.03.033 · Cited by 25
Vaast, A., Vos, J. D., Broeckhoven, K., Verstraeten, M., Eeltink, S., & Desmet, G. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.07.031 · Cited by 25
Desire, C. T., Arrua, R. D., Talebi, M., Lacher, N. A., & Hilder, E. F. (2013) · Journal of Separation Science · doi:10.1002/jssc.201300558 · Cited by 25
Fast separations of intact proteins by liquid chromatography
Wang, F., Min, Y., & Geng, X. (2012) · Journal of Separation Science · doi:10.1002/jssc.201200339 · Cited by 25
Jakschitz, T. A. E., Huck, C. W., Lubbad, S. H., & Bonn, G. K. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.02.078 · Cited by 24
Badaloni, E., Barbarino, M., Cabri, W., D’Acquarica, I., Forte, M., Gasparrini, F., Giorgi, F., Pierini, M., Simone, P., Ursini, O., et al. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.04.048 · Cited by 18
Self-citationKurganov, A. A., Victorova, E., & Kanat’eva, A. Y. (2015) · Journal of Separation Science · doi:10.1002/jssc.201500211 · Cited by 10
Preparation and Evaluation of a Porous P(NIPAAm-MAA-EDMA) Monolithic Column for HPLC
Duan, Y., Liu, H., Li, J., Ma, J., Gu, Y., Yan, C., & Yang, G. (2011) · Chromatographia · doi:10.1007/s10337-011-2169-1 · Cited by 9
Research works printed but not linked: 4
- 10.1021/ac010046q · DOI · Paper page
- Terborg L., 2014, Sci. Chrom., 6, 27
- Angelini G., 2008, PCT Int. Appl.
- Chakraborty A. B., 2005, J. Biomol. Tech., 16, 327
Cited by
Top-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Top-down proteomics: challenges, innovations, and applications in basic and clinical research
Brown, K. A., Melby, J. A., Roberts, D. S., & Ge, Y. (2020) · Expert Review of Proteomics · doi:10.1080/14789450.2020.1855982 · Cited by 152
Lynch, K. B., Ren, J., Beckner, M. A., He, C., & Liu, S. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.09.021 · Cited by 111
Eeltink, S., Wouters, S., Dores‐Sousa, J. L., & Švec, F. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.01.002 · Cited by 82
Carbon footprint of the analytical laboratory and the three-dimensional approach to its reduction
Nowak, P. M., Bis, A., Rusin, M., & Woźniakiewicz, M. (2023) · Green Analytical Chemistry · doi:10.1016/j.greeac.2023.100051 · Cited by 55
Metadata
- Authors
- Simone, P., Pierri, G., Foglia, P., Gasparrini, F., Mazzoccanti, G., Capriotti, A. L., Ursini, O., Ciogli, A., & Laganà, A.
- Affiliations
- Sapienza University of Rome (IT)
- The Francis Crick Institute (GB)
- Istituto di Metodologie Chimiche (IT)
- Corresponding author
- Ciogli, Alessia
- ORCID
- Venue
- Journal of Separation Science
- Publisher
- Wiley
- Published
- 2015-12-07
- Volume
- 39
- Issue
- 2
- Pages
- 264-271
- ISSN
- 1615-9306 (ISSN-L)
- 1615-9314
- OpenAlex
- W2146721091
- Cited by
- 24
- References
- 50
- Citations by year
- 2026: 2 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 2 · 2020: 1 · 2019: 2 · 2018: 5 · 2017: 5 · 2016: 2
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Separation Science (publishedVersion)
- PubMed (publishedVersion)
- IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
- Funders
- REGIONE LAZIO-CRUL/Sapienza (DGR n.412, 2009)
- Scientific Research 2012
- Topics
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Keywords
- gamma-ray induced polymerization, reversed-phase ion-pair chromatography, protein separation, peak capacity, column permeability, electrospray ionization, high-resolution mass spectrometry, trifluoroacetic acid, column temperature, proteomics
- MeSH terms
- Chromatography, High Pressure Liquid, Polymethacrylic Acids, Proteins, Spectrometry, Mass, Electrospray Ionization
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.