Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.

Separation of intact proteins on γ‐ray‐induced polymethacrylate monolithic columns: A highly permeable stationary phase with high peak capacity for capillary high‐performance liquid chromatography with high‐resolution mass spectrometry

Abstract

Polymethacrylate‐based monolithic capillary columns, prepared by γ‐radiation‐induced polymerization, were used to optimize the experimental conditions (nature of the organic modifiers, the content of trifluoroacetic acid and the column temperature) in the separation of nine standard proteins with different hydrophobicities and a wide range of molecular weights. Because of the excellent permeability of the monolithic columns, an ion‐pair reversed‐phase capillary liquid chromatography with high‐resolution mass spectrometry method has been developed by coupling the column directly to the mass spectrometer without a flow‐split and using a standard electrospray interface. Additionally, the high working flow and concomitant high efficiency of these columns allowed us to employ a longer column (up to 50 cm) and achieve a peak capacity value superior to 1000. This work is motivated by the need to develop new materials for high‐resolution chromatographic separation that combine chemical stability at elevated temperatures (up to 75°C) and a broad pH range, with a high peak capacity value. The advantage of the γ‐ray‐induced monolithic column lies in the batch‐to‐batch reproducibility and long‐term high‐temperature stability. Their proven high loading capacity, recovery, good selectivity and high permeability, moreover, compared well with that of a commercially available poly(styrene‐divinylbenzene) monolithic column, which confirms that such monolithic supports might facilitate analysis in proteomics.

Overview

Integrity signals

Registry

Crossref · 10.1002/jssc.201500844

Cites

51 of 51 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Research works printed but not linked: 4

  1. 10.1021/ac010046q · DOI · Paper page
  2. Terborg L., 2014, Sci. Chrom., 6, 27
  3. Angelini G., 2008, PCT Int. Appl.
  4. Chakraborty A. B., 2005, J. Biomol. Tech., 16, 327

Cited by

See all 24

Metadata

Authors
Simone, P., Pierri, G., Foglia, P., Gasparrini, F., Mazzoccanti, G., Capriotti, A. L., Ursini, O., Ciogli, A., & Laganà, A.
Affiliations
  • Sapienza University of Rome (IT)
  • The Francis Crick Institute (GB)
  • Istituto di Metodologie Chimiche (IT)
Corresponding author
Ciogli, Alessia
Venue
Journal of Separation Science
Publisher
Wiley
Published
2015-12-07
Volume
39
Issue
2
Pages
264-271
ISSN
  • 1615-9306 (ISSN-L)
  • 1615-9314
OpenAlex
W2146721091
Cited by
24
References
50
Citations by year
2026: 2 · 2024: 2 · 2023: 1 · 2022: 2 · 2021: 2 · 2020: 1 · 2019: 2 · 2018: 5 · 2017: 5 · 2016: 2
FWCI
1.78
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Separation Science (publishedVersion)
  • PubMed (publishedVersion)
  • IRIS Research product catalog (Sapienza University of Rome) (submittedVersion)
Funders
  • REGIONE LAZIO-CRUL/Sapienza (DGR n.412, 2009)
  • Scientific Research 2012
Topics
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Chromatography
  • Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
gamma-ray induced polymerization, reversed-phase ion-pair chromatography, protein separation, peak capacity, column permeability, electrospray ionization, high-resolution mass spectrometry, trifluoroacetic acid, column temperature, proteomics
MeSH terms
Chromatography, High Pressure Liquid, Polymethacrylic Acids, Proteins, Spectrometry, Mass, Electrospray Ionization

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.