Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 605

The DOI matches its Crossref record.

Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry

Kelleher, Neil L., Lin, Hong Y., Valaskovic, Gary A., Aaserud, David J., Fridriksson, Einar K., McLafferty, Fred W.·1999·Journal of the American Chemical Society

Abstract

Characterization of larger proteins by mass spectrometry (MS) is especially promising because the information complements that of classical techniques and can be obtained on as little as 10 - 17 mol of protein. Using MS to localize errors in the DNA-derived sequence or modifications (posttranslational, derivatized active sites, etc.) usually involves extensive proteolysis to yield peptides of <3 kDa, with separation and MS/MS to compare their sequences to those expected (the “bottom up” approach). In contrast, an alternative “top down” approach limits the dissociation (proteolysis or MS/MS) to yield larger products from which a small set of complementary peptides can be found whose masses sum to those of the molecule. Thus a disagreement with the predicted molecular mass can be localized to a fragment(s) without examining all others, with further dissociation of the fragments in the same way providing further localization. Using carbonic anhydrase (29 kDa) as an example, Fourier transform mass spectrometry is unusually effective for the bottom up approach, in that a single spectrum of an extensive chymotryptic digest identifies 64 expected peptides, but these only cover 95% of the sequence; 20 fragment masses are unassigned so that any set whose masses sum to that of the molecule would be misleading. Extensive Lys-C dissociation yields 17 peptides, 23 unassigned masses, and 96% coverage. In the contrasting “top down” approach, less extensive initial dissociation by Lys-C, MS/MS, or CNBr in each case provides 100% coverage, so that modified protein fragment(s) could easily be recognized among the complementary sets. MS/MS of such a fragment or more extensive proteolysis provide further localization of the modification. The combined methods cleaved 137 of the 258 amide bonds between residues.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/ja973655h

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 605

Metadata

Authors
Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W.
Venue
Journal of the American Chemical Society
Published
1999-01-16
Volume
121
Issue
4
Pages
806-812
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W1977291445
Cited by
605
References
0
FWCI
11.73
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ja973655h
The paper
Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W. (1999). Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry. Journal of the American Chemical Society. https://doi.org/10.1021/ja973655h

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.