The DOI matches its Crossref record.
Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry
Abstract
Characterization of larger proteins by mass spectrometry (MS) is especially promising because the information complements that of classical techniques and can be obtained on as little as 10 - 17 mol of protein. Using MS to localize errors in the DNA-derived sequence or modifications (posttranslational, derivatized active sites, etc.) usually involves extensive proteolysis to yield peptides of <3 kDa, with separation and MS/MS to compare their sequences to those expected (the “bottom up” approach). In contrast, an alternative “top down” approach limits the dissociation (proteolysis or MS/MS) to yield larger products from which a small set of complementary peptides can be found whose masses sum to those of the molecule. Thus a disagreement with the predicted molecular mass can be localized to a fragment(s) without examining all others, with further dissociation of the fragments in the same way providing further localization. Using carbonic anhydrase (29 kDa) as an example, Fourier transform mass spectrometry is unusually effective for the bottom up approach, in that a single spectrum of an extensive chymotryptic digest identifies 64 expected peptides, but these only cover 95% of the sequence; 20 fragment masses are unassigned so that any set whose masses sum to that of the molecule would be misleading. Extensive Lys-C dissociation yields 17 peptides, 23 unassigned masses, and 96% coverage. In the contrasting “top down” approach, less extensive initial dissociation by Lys-C, MS/MS, or CNBr in each case provides 100% coverage, so that modified protein fragment(s) could easily be recognized among the complementary sets. MS/MS of such a fragment or more extensive proteolysis provide further localization of the modification. The combined methods cleaved 137 of the 258 amide bonds between residues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Statistical Model for Identifying Proteins by Tandem Mass Spectrometry
Nesvizhskii, A. I., Keller, A., Kolker, E., & Aebersold, R. (2003) · Analytical Chemistry · doi:10.1021/ac0341261 · Cited by 4,809
Proteomics by Mass Spectrometry: Approaches, Advances, and Applications
Yates, J. R., Ruse, C. I., & Nakorchevsky, A. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124934 · Cited by 1,078
Progress in Top-Down Proteomics and the Analysis of Proteoforms
Toby, T. K., Fornelli, L., & Kelleher, N. L. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041550 · Cited by 576
Self-citationAutomated reduction and interpretation of
Horn, D. M., Zubarev, R. A., & McLafferty, F. W. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(99)00157-9 · Cited by 507
Self-citationDecoding protein modifications using top-down mass spectrometry
Siuti, N., & Kelleher, N. L. (2007) · Nature Methods · doi:10.1038/nmeth1097 · Cited by 503
Self-citation
Metadata
- Authors
- Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 1999-01-16
- Volume
- 121
- Issue
- 4
- Pages
- 806-812
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W1977291445
- Cited by
- 605
- References
- 0
- FWCI
- 11.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry. https://app.cochat.ai/papers/10.1021/ja973655h
- The paper
- Kelleher, N. L., Lin, H. Y., Valaskovic, G. A., Aaserud, D. J., Fridriksson, E. K., & McLafferty, F. W. (1999). Top Down versus Bottom Up Protein Characterization by Tandem High-Resolution Mass Spectrometry. Journal of the American Chemical Society. https://doi.org/10.1021/ja973655h
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.